OpenStudio Results

Model Summary


Data Value
Building Name Building 1
Total Site Energy 1,505,124 kBtu
Net Site Energy 441,256 kBtu
Total Building Area 65,000 ft^2
Total Site EUI 23.16 kBtu/ft^2
Net Site EUI 6.79 kBtu/ft^2
OpenStudio Standards Building Type MidriseApartment

Value
Weather File Los Angeles Intl Arpt CA USA TMY3 WMO#=722950
Latitude 33.93
Longitude -118.4
Elevation 98 ft
Time Zone -8.0
North Axis Angle 0.00
ASHRAE Climate Zone 3C

Maximum Dry Bulb (F) Daily Temperature Range (R) Humidity Value Humidity Type Wind Speed (mph) Wind Direction
LOS ANGELES INTL ARPT ANN CLG .4% CONDNS DB=>MWB 1 83.66 10.8 64.22 Wetbulb [F] 9.17 250.0
LOS ANGELES INTL ARPT ANN CLG .4% CONDNS WB=>MDB 1 78.08 10.8 70.16 Wetbulb [F] 9.17 250.0
LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1 44.42 0.0 44.42 Wetbulb [F] 5.37 90.0

Time Setpoint Not Met Time (hr)
During Heating 0.0
During Cooling 0.0
During Occupied Heating 0.0
During Occupied Cooling 0.0

Tolerance for Time Setpoint Not Met Temperature (F)
Heating 1.01
Cooling 1.01

Rated Capacity (kW) Annual Energy Generated (kWh)
Photovoltaic 0.0 324780.56
Wind 0.0 0.0

Annual Overview


End Use Consumption (kBtu)
Heating 140,751
Cooling 471,909
Interior Lighting 183,450
Exterior Lighting 15,885
Interior Equipment 584,670
Exterior Equipment 0
Fans 0
Pumps 14,075
Heat Rejection 0
Humidification 0
Heat Recovery 0
Water Systems 94,374
Refrigeration 0
Generators 0

Fuel Consumption (kBtu)
Electricity 958,963
Natural Gas 0
Additional Fuel 0
District Cooling 471,909
District Heating 74,243

End Use Consumption (kWh)
Heating 19,492
Cooling 0
Interior Lighting 53,764
Exterior Lighting 4,656
Interior Equipment 171,350
Exterior Equipment 0
Fans 0
Pumps 4,125
Heat Rejection 0
Humidification 0
Heat Recovery 0
Water Systems 27,658
Refrigeration 0
Generators 0

End Use Consumption (therms)
Heating 0
Cooling 0
Interior Lighting 0
Exterior Lighting 0
Interior Equipment 0
Exterior Equipment 0
Fans 0
Pumps 0
Heat Rejection 0
Humidification 0
Heat Recovery 0
Water Systems 0
Refrigeration 0
Generators 0

Monthly Overview


Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Total
Heating 1769.59 1612.64 1754.58 1646.99 1623.97 1515.78 1529.88 1529.11 1508.11 1616.02 1633.35 1751.79 19491.8
Cooling
Interior Lighting 4930.08 4417.89 4718.17 4360.89 4363.89 4086.44 4212.08 4276.47 4273.06 4609.69 4639.81 4874.11 53762.58
Exterior Lighting 472.59 395.63 395.18 351.84 335.52 310.65 323.66 348.41 372.23 420.62 445.68 482.91 4654.93
Interior Equipment 16308.67 14816.39 14657.5 14156.61 14661.17 12741.36 13166.06 13191.75 12802.89 14468.11 14013.78 16366.5 171350.78
Exterior Equipment
Fans
Pumps 347.63 316.63 350.56 339.25 350.56 339.25 350.56 350.56 339.25 350.56 339.25 350.56 4124.6
Heat Rejection
Humidification
Heat Recovery
Water Systems 2423.91 2193.51 2424.16 2303.79 2321.64 2219.9 2256.35 2265.88 2211.39 2321.69 2294.34 2423.07 27659.62
Refrigeration
Generators
Total 26252.48 23752.68 24300.14 23159.36 23656.75 21213.38 21838.59 21962.18 21506.93 23786.7 23366.19 26248.94 281044.31

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Total
Heating
Cooling 15.46 14.6 11.62 19.69 29.26 46.31 75.6 80.92 82.81 49.38 29.28 17.0 471.91
Interior Lighting
Exterior Lighting
Interior Equipment
Exterior Equipment
Fans
Pumps
Heat Rejection
Humidification
Heat Recovery
Water Systems
Refrigeration
Generators
Total 15.46 14.6 11.62 19.69 29.26 46.31 75.6 80.92 82.81 49.38 29.28 17.0 471.91

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Total
Heating 17.04 11.3 11.78 7.25 3.94 1.0 0.21 0.09 0.34 2.61 6.76 11.92 74.25
Cooling
Interior Lighting
Exterior Lighting
Interior Equipment
Exterior Equipment
Fans
Pumps
Heat Rejection
Humidification
Heat Recovery
Water Systems
Refrigeration
Generators
Total 17.04 11.3 11.78 7.25 3.94 1.0 0.21 0.09 0.34 2.61 6.76 11.92 74.25

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Heating 3.2347 3.254 3.1312 3.0167 2.9866 2.8775 2.798 2.7995 2.7928 2.855 3.1213 3.0977
Cooling
Interior Lighting 8.5038 8.4223 7.5987 7.8868 7.2344 7.1438 7.0884 7.1439 7.2362 7.5739 7.762 7.981
Exterior Lighting
Interior Equipment 316.7076 316.8013 314.1925 314.1368 314.1925 312.1025 312.0547 312.0547 312.1025 314.0733 314.0261 316.7076
Exterior Equipment
Fans
Pumps 0.4712 0.4712 0.4712 0.4712 0.4712 0.4712 0.4712 0.4712 0.4712 0.4712 0.4712 0.4712
Heat Rejection
Humidification
Heat Recovery
Water Systems 37.0043 37.0021 36.9986 36.9763 36.963 36.9693 36.9753 36.9939
Refrigeration
Generators
Total 365.92 328.95 362.4 362.51 361.86 322.59 322.41 359.43 359.57 361.95 325.38 365.25

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Heating
Cooling 190.0994 229.1922 147.3969 278.4541 234.4949 258.7975 354.0621 330.3493 394.0951 263.8503 250.4163 167.4022
Interior Lighting
Exterior Lighting
Interior Equipment
Exterior Equipment
Fans
Pumps
Heat Rejection
Humidification
Heat Recovery
Water Systems
Refrigeration
Generators
Total 190.1 229.19 147.4 278.45 234.49 258.8 354.06 330.35 394.1 263.85 250.42 167.4

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Heating 175.6554 136.1034 130.4091 89.2835 49.4745 22.9029 16.7572 5.7796 16.9748 59.07 99.2771 108.7379
Cooling
Interior Lighting
Exterior Lighting
Interior Equipment
Exterior Equipment
Fans
Pumps
Heat Rejection
Humidification
Heat Recovery
Water Systems
Refrigeration
Generators
Total 175.66 136.1 130.41 89.28 49.47 22.9 16.76 5.78 16.97 59.07 99.28 108.74

Utility Bills/Rates

No Data to Show for Utility Bills/Rates

Envelope Summary


Construction Net Area (ft^2) Surface Count R Value (ft^2*h*R/Btu)
Typical IEAD Roof R-34.48 13,000 20 33.70
Typical Insulated Wood Framed Exterior Wall R-34.48 20,034 92 33.63

Construction Net Area (ft^2) Surface Count U-factor (Btu/ft^2*h*R) SHGC VLT
U 0.25 SHGC 0.22 Simple Glazing Window U-0.25 SHGC 0.22 53 63 0.32 0.22 0.24
U 0.25 SHGC 0.24 Simple Glazing Window U-0.25 SHGC 0.24 21 29 0.32 0.24 0.27

Material Name
(Material Layers in Construction 'U 0.25 SHGC 0.22 Simple Glazing Window U-0.25 SHGC 0.22':)
U 0.25 SHGC 0.22 Simple Glazing U-0.32 SHGC 0.22
(Material Layers in Construction 'U 0.25 SHGC 0.24 Simple Glazing Window U-0.25 SHGC 0.24':)
U 0.25 SHGC 0.24 Simple Glazing U-0.32 SHGC 0.24

Description Total (%) North (%) East (%) South (%) West (%)
Gross Window-Wall Ratio 30.0 30.0 30.0 30.0 30.0
Gross Window-Wall Ratio (Conditioned) 30.0 30.0 30.0 30.0 30.0
Skylight-Roof Ratio 0.0

Space Type Breakdown


Space Type Name Floor Area (ft^2) Standards Building Type Standards Space Type
bathroom - 300 SmallHotel PublicRestroom
coffee - 1,500 QuickServiceRestaurant Dining
community - 1,500 SmallHotel Meeting
corridor 5 - 4,200 MidriseApartment Corridor
elevator - 1,000 SmallHotel ElevatorCore
garbage 2 - 450 SmallHotel Storage
gym 2 - 1,050 SmallHotel Exercise
living - 45,600 MidriseApartment Apartment
lobby - 600 Retail Entry
mail - 450 SmallHotel Storage
office 2 - 750 MidriseApartment Office
retail - 4,600 Retail Core_Retail
stair - 3,000 SmallHotel Stair

Space Type Summary


Definition Value Unit Inst. Multiplier
bathroom People Definition 0.0028 people/ft^2 1.0
bathroom Lights Definition 0.4000 W/ft^2 1.0
bathroom Ventilation (outdoor air method Sum) 0.0600 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
coffee People Definition 0.0700 people/ft^2 1.0
coffee Elec Equip Definition 0.5000 W/ft^2 1.0
coffee Lights Definition 0.4000 W/ft^2 1.0
coffee Ventilation (outdoor air method Sum) 7.5000 cfm/person
coffee Ventilation (outdoor air method Sum) 0.1800 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
community People Definition 0.0500 people/ft^2 1.0
community Elec Equip Definition 0.5740 W/ft^2 1.0
community Lights Definition 0.3000 W/ft^2 1.0
community Ventilation (outdoor air method Sum) 5.0000 cfm/person
community Ventilation (outdoor air method Sum) 0.0600 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
corridor 5 Lights Definition 0.4000 W/ft^2 1.0

Definition Value Unit Inst. Multiplier
elevator Ventilation (outdoor air method Sum) 0.1200 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
garbage 2 Lights Definition 0.3000 W/ft^2 1.0
garbage 2 Ventilation (outdoor air method Sum) 0.1200 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
gym 2 People Definition 0.0199 people/ft^2 1.0
gym 2 Elec Equip Definition 1.7300 W/ft^2 1.0
gym 2 Lights Definition 0.3000 W/ft^2 1.0
gym 2 Ventilation (outdoor air method Sum) 20.0000 cfm/person
gym 2 Ventilation (outdoor air method Sum) 0.0600 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
living Ventilation (outdoor air method Sum) 0.3500 ach

Definition Value Unit Inst. Multiplier
lobby People Definition 0.0150 people/ft^2 1.0
lobby Elec Equip Definition 0.3000 W/ft^2 1.0
lobby Lights Definition 0.4000 W/ft^2 1.0
lobby Ventilation (outdoor air method Sum) 7.5000 cfm/person
lobby Ventilation (outdoor air method Sum) 0.1200 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
mail Lights Definition 0.3000 W/ft^2 1.0
mail Ventilation (outdoor air method Sum) 0.1200 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
office 2 People Definition 0.0021 people/ft^2 1.0
office 2 Elec Equip Definition 0.6197 W/ft^2 1.0
office 2 Lights Definition 0.3000 W/ft^2 1.0
office 2 Ventilation (outdoor air method Sum) 0.0850 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
retail People Definition 0.0150 people/ft^2 1.0
retail Elec Equip Definition 0.3000 W/ft^2 1.0
retail Lights Definition 0.5000 W/ft^2 1.0
retail Ventilation (outdoor air method Sum) 7.5000 cfm/person
retail Ventilation (outdoor air method Sum) 0.1200 cfm/ floor area ft^2

Definition Value Unit Inst. Multiplier
stair Lights Definition 0.4000 W/ft^2 1.0
stair Ventilation (outdoor air method Sum) 0.0600 cfm/ floor area ft^2

Interior Lighting Summary


Lights Zone Lighting Power Density (W/ft^2) Total Power (W) Schedule Name Scheduled Hours/Week (hr) Actual Load Hours/Week (hr) Return Air Fraction Annual Consumption (kWh)
RES LIGHTING INTERIOR|BUILDING UNIT 001 0_BDRM_1_2 0_BDRM_1_2 0.21 95.81 RES LIGHTING INTERIOR 63.89 63.89 0.0000 319.44
RES LIGHTING INTERIOR|BUILDING UNIT 005 0_BDRM_1_3 0_BDRM_1_3 0.21 191.63 RES LIGHTING INTERIOR 63.89 63.89 0.0000 638.89
RES LIGHTING INTERIOR|BUILDING UNIT 009 0_BDRM_1_4 0_BDRM_1_4 0.21 95.81 RES LIGHTING INTERIOR 63.89 63.89 0.0000 319.44
RES LIGHTING INTERIOR|BUILDING UNIT 002 0_BDRM_2_2 0_BDRM_2_2 0.21 95.81 RES LIGHTING INTERIOR 63.89 63.89 0.0000 319.44
RES LIGHTING INTERIOR|BUILDING UNIT 006 0_BDRM_2_3 0_BDRM_2_3 0.21 191.63 RES LIGHTING INTERIOR 63.89 63.89 0.0000 638.89
RES LIGHTING INTERIOR|BUILDING UNIT 010 0_BDRM_2_4 0_BDRM_2_4 0.21 95.81 RES LIGHTING INTERIOR 63.89 63.89 0.0000 319.44
RES LIGHTING INTERIOR|BUILDING UNIT 003 0_BDRM_3_2 0_BDRM_3_2 0.21 95.81 RES LIGHTING INTERIOR 63.89 63.89 0.0000 319.44
RES LIGHTING INTERIOR|BUILDING UNIT 007 0_BDRM_3_3 0_BDRM_3_3 0.21 191.63 RES LIGHTING INTERIOR 63.89 63.89 0.0000 638.89
RES LIGHTING INTERIOR|BUILDING UNIT 011 0_BDRM_3_4 0_BDRM_3_4 0.21 95.81 RES LIGHTING INTERIOR 63.89 63.89 0.0000 319.44
RES LIGHTING INTERIOR|BUILDING UNIT 004 0_BDRM_4_2 0_BDRM_4_2 0.21 95.81 RES LIGHTING INTERIOR 63.89 63.89 0.0000 319.44
RES LIGHTING INTERIOR|BUILDING UNIT 008 0_BDRM_4_3 0_BDRM_4_3 0.21 191.63 RES LIGHTING INTERIOR 63.89 63.89 0.0000 638.89
RES LIGHTING INTERIOR|BUILDING UNIT 012 0_BDRM_4_4 0_BDRM_4_4 0.21 95.81 RES LIGHTING INTERIOR 63.89 63.89 0.0000 319.44
RES LIGHTING INTERIOR|BUILDING UNIT 101 1_BDRM_1_2 1_BDRM_1_2 0.18 109.29 RES LIGHTING INTERIOR 63.89 63.89 0.0000 363.89
RES LIGHTING INTERIOR|BUILDING UNIT 108 1_BDRM_1_3 1_BDRM_1_3 0.18 218.59 RES LIGHTING INTERIOR 63.89 63.89 0.0000 727.78
RES LIGHTING INTERIOR|BUILDING UNIT 115 1_BDRM_1_4 1_BDRM_1_4 0.18 109.29 RES LIGHTING INTERIOR 63.89 63.89 0.0000 363.89
RES LIGHTING INTERIOR|BUILDING UNIT 102 1_BDRM_2_2 1_BDRM_2_2 0.18 109.29 RES LIGHTING INTERIOR 63.89 63.89 0.0000 363.89
RES LIGHTING INTERIOR|BUILDING UNIT 109 1_BDRM_2_3 1_BDRM_2_3 0.18 218.59 RES LIGHTING INTERIOR 63.89 63.89 0.0000 727.78
RES LIGHTING INTERIOR|BUILDING UNIT 116 1_BDRM_2_4 1_BDRM_2_4 0.18 109.29 RES LIGHTING INTERIOR 63.89 63.89 0.0000 363.89
RES LIGHTING INTERIOR|BUILDING UNIT 103 1_BDRM_3_2 1_BDRM_3_2 0.18 109.29 RES LIGHTING INTERIOR 63.89 63.89 0.0000 363.89
RES LIGHTING INTERIOR|BUILDING UNIT 110 1_BDRM_3_3 1_BDRM_3_3 0.18 218.59 RES LIGHTING INTERIOR 63.89 63.89 0.0000 727.78
RES LIGHTING INTERIOR|BUILDING UNIT 117 1_BDRM_3_4 1_BDRM_3_4 0.18 109.29 RES LIGHTING INTERIOR 63.89 63.89 0.0000 363.89
RES LIGHTING INTERIOR|BUILDING UNIT 104 1_BDRM_4_2 1_BDRM_4_2 0.16 122.77 RES LIGHTING INTERIOR 63.89 63.89 0.0000 408.33
RES LIGHTING INTERIOR|BUILDING UNIT 111 1_BDRM_4_3 1_BDRM_4_3 0.16 245.55 RES LIGHTING INTERIOR 63.89 63.89 0.0000 819.44
RES LIGHTING INTERIOR|BUILDING UNIT 118 1_BDRM_4_4 1_BDRM_4_4 0.16 122.77 RES LIGHTING INTERIOR 63.89 63.89 0.0000 408.33
RES LIGHTING INTERIOR|BUILDING UNIT 105 1_BDRM_5_2 1_BDRM_5_2 0.16 122.77 RES LIGHTING INTERIOR 63.89 63.89 0.0000 408.33
RES LIGHTING INTERIOR|BUILDING UNIT 112 1_BDRM_5_3 1_BDRM_5_3 0.16 245.55 RES LIGHTING INTERIOR 63.89 63.89 0.0000 819.44
RES LIGHTING INTERIOR|BUILDING UNIT 119 1_BDRM_5_4 1_BDRM_5_4 0.16 122.77 RES LIGHTING INTERIOR 63.89 63.89 0.0000 408.33
RES LIGHTING INTERIOR|BUILDING UNIT 106 1_BDRM_6_2 1_BDRM_6_2 0.18 109.29 RES LIGHTING INTERIOR 63.89 63.89 0.0000 363.89
RES LIGHTING INTERIOR|BUILDING UNIT 113 1_BDRM_6_3 1_BDRM_6_3 0.18 218.59 RES LIGHTING INTERIOR 63.89 63.89 0.0000 727.78
RES LIGHTING INTERIOR|BUILDING UNIT 120 1_BDRM_6_4 1_BDRM_6_4 0.18 109.29 RES LIGHTING INTERIOR 63.89 63.89 0.0000 363.89
RES LIGHTING INTERIOR|BUILDING UNIT 107 1_BDRM_7_2 1_BDRM_7_2 0.16 122.77 RES LIGHTING INTERIOR 63.89 63.89 0.0000 408.33
RES LIGHTING INTERIOR|BUILDING UNIT 114 1_BDRM_7_3 1_BDRM_7_3 0.16 245.55 RES LIGHTING INTERIOR 63.89 63.89 0.0000 819.44
RES LIGHTING INTERIOR|BUILDING UNIT 121 1_BDRM_7_4 1_BDRM_7_4 0.16 122.77 RES LIGHTING INTERIOR 63.89 63.89 0.0000 408.33
RES LIGHTING INTERIOR|BUILDING UNIT 201 2_BDRM_1_2 2_BDRM_1_2 0.14 154.22 RES LIGHTING INTERIOR 63.89 63.89 0.0000 513.89
RES LIGHTING INTERIOR|BUILDING UNIT 204 2_BDRM_1_3 2_BDRM_1_3 0.14 308.45 RES LIGHTING INTERIOR 63.89 63.89 0.0000 1027.78
RES LIGHTING INTERIOR|BUILDING UNIT 207 2_BDRM_1_4 2_BDRM_1_4 0.14 154.22 RES LIGHTING INTERIOR 63.89 63.89 0.0000 513.89
RES LIGHTING INTERIOR|BUILDING UNIT 202 2_BDRM_2_2 2_BDRM_2_2 0.14 163.21 RES LIGHTING INTERIOR 63.89 63.89 0.0000 544.44
RES LIGHTING INTERIOR|BUILDING UNIT 205 2_BDRM_2_3 2_BDRM_2_3 0.14 326.42 RES LIGHTING INTERIOR 63.89 63.89 0.0000 1088.89
RES LIGHTING INTERIOR|BUILDING UNIT 208 2_BDRM_2_4 2_BDRM_2_4 0.14 163.21 RES LIGHTING INTERIOR 63.89 63.89 0.0000 544.44
RES LIGHTING INTERIOR|BUILDING UNIT 203 2_BDRM_3_2 2_BDRM_3_2 0.14 158.72 RES LIGHTING INTERIOR 63.89 63.89 0.0000 527.78
RES LIGHTING INTERIOR|BUILDING UNIT 206 2_BDRM_3_3 2_BDRM_3_3 0.14 317.43 RES LIGHTING INTERIOR 63.89 63.89 0.0000 1058.33
RES LIGHTING INTERIOR|BUILDING UNIT 209 2_BDRM_3_4 2_BDRM_3_4 0.14 158.72 RES LIGHTING INTERIOR 63.89 63.89 0.0000 527.78
RES LIGHTING INTERIOR|BUILDING UNIT 302 3_BDRM_1_3 3_BDRM_1_3 0.13 380.34 RES LIGHTING INTERIOR 63.89 63.89 0.0000 1266.67
RES LIGHTING INTERIOR|BUILDING UNIT 303 3_BDRM_1_4 3_BDRM_1_4 0.13 190.17 RES LIGHTING INTERIOR 63.89 63.89 0.0000 633.33
RES LIGHTING INTERIOR|BUILDING UNIT 301 3_BDRM_2_2 3_BDRM_2_2 0.13 190.17 RES LIGHTING INTERIOR 63.89 63.89 0.0000 633.33
BATHRM_1 BATHROOM LIGHTS BATHRM_1 0.4 60.0 HOTELSMALL BLDG_LIGHT_RESTROOM_SCH 110.88 110.88 0.0000 347.22
BATHRM_2 BATHROOM LIGHTS BATHRM_2 0.4 60.0 HOTELSMALL BLDG_LIGHT_RESTROOM_SCH 110.88 110.88 0.0000 347.22
COFFEE_SHOP COFFEE LIGHTS COFFEE_SHOP 0.4 600.0 RESTAURANTFASTFOOD BLDG_LIGHT_DINING_SCH_2013 91.27 91.27 0.0000 2855.56
COMMUNITY_RM COMMUNITY LIGHTS COMMUNITY_RM 0.3 450.0 HOTELSMALL BLDG_LIGHT_MEETINGROOM_SCH 84.35 84.35 0.0000 1980.56
CORRIDOR 1 CORRIDOR 5 LIGHTS CORRIDOR 1 0.4 400.0 APARTMENTMIDRISE LTG_COR_SCH_2013 89.28 89.28 0.0000 1861.11
CORRIDOR_2 CORRIDOR 5 LIGHTS CORRIDOR_2 0.4 320.0 APARTMENTMIDRISE LTG_COR_SCH_2013 89.28 89.28 0.0000 1488.89
CORRIDOR_3 CORRIDOR 5 LIGHTS CORRIDOR_3 0.4 640.0 APARTMENTMIDRISE LTG_COR_SCH_2013 89.28 89.28 0.0000 2980.56
CORRIDOR_4 CORRIDOR 5 LIGHTS CORRIDOR_4 0.4 320.0 APARTMENTMIDRISE LTG_COR_SCH_2013 89.28 89.28 0.0000 1488.89
GARBAGE 1 GARBAGE 2 LIGHTS GARBAGE 1 0.3 135.0 HOTELSMALL BLDG_LIGHT_STORAGE_SCH 22.38 22.38 0.0000 158.33
GYM 1 GYM 2 LIGHTS GYM 1 0.3 315.0 HOTELSMALL BLDG_LIGHT_EXERCENTER_SCH 112.0 112.0 0.0000 1838.89
LOBBY_ENTRY LOBBY LIGHTS LOBBY_ENTRY 0.4 240.0 RETAILSTANDALONE BLDG_LIGHT_ENTRY_SCH_2013 57.63 57.63 0.0000 722.22
MAIL_SHIPPING MAIL LIGHTS MAIL_SHIPPING 0.3 135.0 HOTELSMALL BLDG_LIGHT_STORAGE_SCH 22.38 22.38 0.0000 158.33
OFFICE 1 OFFICE 2 LIGHTS OFFICE 1 0.3 225.0 APARTMENTMIDRISE LTG_OFF_SCH_2010_2013 56.36 56.36 0.0000 661.11
LT_RETAIL_1 RETAIL LIGHTS LT_RETAIL_1 0.5 675.0 RETAILSTANDALONE BLDG_LIGHT_SCH_2013 69.32 55.69 0.0000 1961.11
LT_RETAIL_2 RETAIL LIGHTS LT_RETAIL_2 0.5 550.0 RETAILSTANDALONE BLDG_LIGHT_SCH_2013 69.32 45.03 0.0000 1291.67
LT_RETAIL_3 RETAIL LIGHTS LT_RETAIL_3 0.5 525.0 RETAILSTANDALONE BLDG_LIGHT_SCH_2013 69.32 69.32 0.0000 1897.22
LT_RETAIL_4 RETAIL LIGHTS LT_RETAIL_4 0.5 550.0 RETAILSTANDALONE BLDG_LIGHT_SCH_2013 69.32 42.67 0.0000 1225.0
STAIR_1 STAIR LIGHTS STAIR_1 0.4 120.0 HOTELSMALL BLDG_LIGHT_STAIR_SCH 92.4 92.4 0.0000 577.78
STAIR_2 STAIR LIGHTS STAIR_2 0.4 120.0 HOTELSMALL BLDG_LIGHT_STAIR_SCH 92.4 92.4 0.0000 577.78
STAIRWELL_1_2 STAIR LIGHTS STAIRWELL_1_2 0.4 120.0 HOTELSMALL BLDG_LIGHT_STAIR_SCH 92.4 92.4 0.0000 577.78
STAIRWELL_1_3 STAIR LIGHTS STAIRWELL_1_3 0.4 240.0 HOTELSMALL BLDG_LIGHT_STAIR_SCH 92.4 92.4 0.0000 1155.56
STAIRWELL_1_4 STAIR LIGHTS STAIRWELL_1_4 0.4 120.0 HOTELSMALL BLDG_LIGHT_STAIR_SCH 92.4 92.4 0.0000 577.78
STAIRWELL_2_2 STAIR LIGHTS STAIRWELL_2_2 0.4 120.0 HOTELSMALL BLDG_LIGHT_STAIR_SCH 92.4 92.4 0.0000 577.78
STAIRWELL_2_3 STAIR LIGHTS STAIRWELL_2_3 0.4 240.0 HOTELSMALL BLDG_LIGHT_STAIR_SCH 92.4 92.4 0.0000 1155.56
STAIRWELL_2_4 STAIR LIGHTS STAIRWELL_2_4 0.4 120.0 HOTELSMALL BLDG_LIGHT_STAIR_SCH 92.4 92.4 0.0000 577.78

Load Name Definition Name Load Type Load (units) Multiplier Total Load (W)
(Space Name: '0_Bdrm_3_4', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 011 0_Bdrm_3_4 res lighting interior|Building Unit 011 0_Bdrm_3_4 Space 96 (W) 1 96
(Space Name: '2_Bdrm_3_3', Area: 1150 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 206 2_Bdrm_3_3 res lighting interior|Building Unit 206 2_Bdrm_3_3 Space 159 (W) 1 159
(Space Name: 'Corridor_4', Area: 800 ft^2, Total LPD: 0.4 W/ft^2)
corridor 5 Lights corridor 5 Lights Definition Spacetype 0.4 (W/ft^2) 1 320
(Space Name: 'Elevator_2_2', Area: 100 ft^2, Total LPD: 0.0 W/ft^2)
- - - - - -
(Space Name: '0_Bdrm_2_4', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 010 0_Bdrm_2_4 res lighting interior|Building Unit 010 0_Bdrm_2_4 Space 96 (W) 1 96
(Space Name: '1_Bdrm_2_3', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 109 1_Bdrm_2_3 res lighting interior|Building Unit 109 1_Bdrm_2_3 Space 109 (W) 1 109
(Space Name: '0_Bdrm_1_3', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 005 0_Bdrm_1_3 res lighting interior|Building Unit 005 0_Bdrm_1_3 Space 96 (W) 1 96
(Space Name: 'Lt_Retail_1', Area: 1350 ft^2, Total LPD: 0.5 W/ft^2)
retail Lights retail Lights Definition Spacetype 0.5 (W/ft^2) 1 675
(Space Name: 'Corridor_3', Area: 800 ft^2, Total LPD: 0.4 W/ft^2)
corridor 5 Lights corridor 5 Lights Definition Spacetype 0.4 (W/ft^2) 1 320
(Space Name: 'Lobby_Entry', Area: 600 ft^2, Total LPD: 0.4 W/ft^2)
lobby Lights lobby Lights Definition Spacetype 0.4 (W/ft^2) 1 240
(Space Name: '0_Bdrm_1_2', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 001 0_Bdrm_1_2 res lighting interior|Building Unit 001 0_Bdrm_1_2 Space 96 (W) 1 96
(Space Name: '1_Bdrm_6_2', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 106 1_Bdrm_6_2 res lighting interior|Building Unit 106 1_Bdrm_6_2 Space 109 (W) 1 109
(Space Name: '0_Bdrm_2_2', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 002 0_Bdrm_2_2 res lighting interior|Building Unit 002 0_Bdrm_2_2 Space 96 (W) 1 96
(Space Name: '0_Bdrm_1_4', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 009 0_Bdrm_1_4 res lighting interior|Building Unit 009 0_Bdrm_1_4 Space 96 (W) 1 96
(Space Name: '2_Bdrm_1_2', Area: 1100 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 201 2_Bdrm_1_2 res lighting interior|Building Unit 201 2_Bdrm_1_2 Space 154 (W) 1 154
(Space Name: '1_Bdrm_4_3', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 111 1_Bdrm_4_3 res lighting interior|Building Unit 111 1_Bdrm_4_3 Space 123 (W) 1 123
(Space Name: 'Bathrm_2', Area: 150 ft^2, Total LPD: 0.4 W/ft^2)
bathroom Lights bathroom Lights Definition Spacetype 0.4 (W/ft^2) 1 60
(Space Name: 'Stair_1', Area: 300 ft^2, Total LPD: 0.4 W/ft^2)
stair Lights stair Lights Definition Spacetype 0.4 (W/ft^2) 1 120
(Space Name: '1_Bdrm_3_3', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 110 1_Bdrm_3_3 res lighting interior|Building Unit 110 1_Bdrm_3_3 Space 109 (W) 1 109
(Space Name: '0_Bdrm_3_2', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 003 0_Bdrm_3_2 res lighting interior|Building Unit 003 0_Bdrm_3_2 Space 96 (W) 1 96
(Space Name: '1_Bdrm_1_2', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 101 1_Bdrm_1_2 res lighting interior|Building Unit 101 1_Bdrm_1_2 Space 109 (W) 1 109
(Space Name: '1_Bdrm_4_2', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 104 1_Bdrm_4_2 res lighting interior|Building Unit 104 1_Bdrm_4_2 Space 123 (W) 1 123
(Space Name: '3_Bdrm_1_4', Area: 1500 ft^2, Total LPD: 0.13 W/ft^2)
res lighting interior|Building Unit 303 3_Bdrm_1_4 res lighting interior|Building Unit 303 3_Bdrm_1_4 Space 190 (W) 1 190
(Space Name: '1_Bdrm_3_2', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 103 1_Bdrm_3_2 res lighting interior|Building Unit 103 1_Bdrm_3_2 Space 109 (W) 1 109
(Space Name: '2_Bdrm_2_2', Area: 1200 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 202 2_Bdrm_2_2 res lighting interior|Building Unit 202 2_Bdrm_2_2 Space 163 (W) 1 163
(Space Name: '0_Bdrm_4_3', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 008 0_Bdrm_4_3 res lighting interior|Building Unit 008 0_Bdrm_4_3 Space 96 (W) 1 96
(Space Name: '0_Bdrm_3_3', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 007 0_Bdrm_3_3 res lighting interior|Building Unit 007 0_Bdrm_3_3 Space 96 (W) 1 96
(Space Name: '1_Bdrm_7_4', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 121 1_Bdrm_7_4 res lighting interior|Building Unit 121 1_Bdrm_7_4 Space 123 (W) 1 123
(Space Name: '1_Bdrm_5_4', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 119 1_Bdrm_5_4 res lighting interior|Building Unit 119 1_Bdrm_5_4 Space 123 (W) 1 123
(Space Name: '0_Bdrm_2_3', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 006 0_Bdrm_2_3 res lighting interior|Building Unit 006 0_Bdrm_2_3 Space 96 (W) 1 96
(Space Name: 'Lt_Retail_2', Area: 1100 ft^2, Total LPD: 0.5 W/ft^2)
retail Lights retail Lights Definition Spacetype 0.5 (W/ft^2) 1 550
(Space Name: '0_Bdrm_4_2', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 004 0_Bdrm_4_2 res lighting interior|Building Unit 004 0_Bdrm_4_2 Space 96 (W) 1 96
(Space Name: 'Elevator_1', Area: 100 ft^2, Total LPD: 0.0 W/ft^2)
- - - - - -
(Space Name: '2_Bdrm_3_2', Area: 1150 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 203 2_Bdrm_3_2 res lighting interior|Building Unit 203 2_Bdrm_3_2 Space 159 (W) 1 159
(Space Name: '1_Bdrm_7_2', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 107 1_Bdrm_7_2 res lighting interior|Building Unit 107 1_Bdrm_7_2 Space 123 (W) 1 123
(Space Name: 'Elevator_2', Area: 100 ft^2, Total LPD: 0.0 W/ft^2)
- - - - - -
(Space Name: 'Stair_2', Area: 300 ft^2, Total LPD: 0.4 W/ft^2)
stair Lights stair Lights Definition Spacetype 0.4 (W/ft^2) 1 120
(Space Name: '1_Bdrm_5_2', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 105 1_Bdrm_5_2 res lighting interior|Building Unit 105 1_Bdrm_5_2 Space 123 (W) 1 123
(Space Name: '0_Bdrm_4_4', Area: 450 ft^2, Total LPD: 0.21 W/ft^2)
res lighting interior|Building Unit 012 0_Bdrm_4_4 res lighting interior|Building Unit 012 0_Bdrm_4_4 Space 96 (W) 1 96
(Space Name: '1_Bdrm_2_4', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 116 1_Bdrm_2_4 res lighting interior|Building Unit 116 1_Bdrm_2_4 Space 109 (W) 1 109
(Space Name: 'Elevator_1_2', Area: 100 ft^2, Total LPD: 0.0 W/ft^2)
- - - - - -
(Space Name: '1_Bdrm_1_3', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 108 1_Bdrm_1_3 res lighting interior|Building Unit 108 1_Bdrm_1_3 Space 109 (W) 1 109
(Space Name: '1_Bdrm_1_4', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 115 1_Bdrm_1_4 res lighting interior|Building Unit 115 1_Bdrm_1_4 Space 109 (W) 1 109
(Space Name: 'Garbage 1', Area: 450 ft^2, Total LPD: 0.3 W/ft^2)
garbage 2 Lights garbage 2 Lights Definition Spacetype 0.3 (W/ft^2) 1 135
(Space Name: '1_Bdrm_2_2', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 102 1_Bdrm_2_2 res lighting interior|Building Unit 102 1_Bdrm_2_2 Space 109 (W) 1 109
(Space Name: '3_Bdrm_1_3', Area: 1500 ft^2, Total LPD: 0.13 W/ft^2)
res lighting interior|Building Unit 302 3_Bdrm_1_3 res lighting interior|Building Unit 302 3_Bdrm_1_3 Space 190 (W) 1 190
(Space Name: 'Corridor 1', Area: 1000 ft^2, Total LPD: 0.4 W/ft^2)
corridor 5 Lights corridor 5 Lights Definition Spacetype 0.4 (W/ft^2) 1 400
(Space Name: '1_Bdrm_3_4', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 117 1_Bdrm_3_4 res lighting interior|Building Unit 117 1_Bdrm_3_4 Space 109 (W) 1 109
(Space Name: 'Elevator_1_3', Area: 100 ft^2, Total LPD: 0.0 W/ft^2)
- - - - - -
(Space Name: 'Corridor_2', Area: 800 ft^2, Total LPD: 0.4 W/ft^2)
corridor 5 Lights corridor 5 Lights Definition Spacetype 0.4 (W/ft^2) 1 320
(Space Name: '1_Bdrm_4_4', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 118 1_Bdrm_4_4 res lighting interior|Building Unit 118 1_Bdrm_4_4 Space 123 (W) 1 123
(Space Name: '2_Bdrm_2_4', Area: 1200 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 208 2_Bdrm_2_4 res lighting interior|Building Unit 208 2_Bdrm_2_4 Space 163 (W) 1 163
(Space Name: '1_Bdrm_5_3', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 112 1_Bdrm_5_3 res lighting interior|Building Unit 112 1_Bdrm_5_3 Space 123 (W) 1 123
(Space Name: 'Elevator_1_4', Area: 100 ft^2, Total LPD: 0.0 W/ft^2)
- - - - - -
(Space Name: 'Elevator_2_4', Area: 100 ft^2, Total LPD: 0.0 W/ft^2)
- - - - - -
(Space Name: '2_Bdrm_3_4', Area: 1150 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 209 2_Bdrm_3_4 res lighting interior|Building Unit 209 2_Bdrm_3_4 Space 159 (W) 1 159
(Space Name: '1_Bdrm_6_3', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 113 1_Bdrm_6_3 res lighting interior|Building Unit 113 1_Bdrm_6_3 Space 109 (W) 1 109
(Space Name: '2_Bdrm_1_3', Area: 1100 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 204 2_Bdrm_1_3 res lighting interior|Building Unit 204 2_Bdrm_1_3 Space 154 (W) 1 154
(Space Name: '1_Bdrm_6_4', Area: 600 ft^2, Total LPD: 0.18 W/ft^2)
res lighting interior|Building Unit 120 1_Bdrm_6_4 res lighting interior|Building Unit 120 1_Bdrm_6_4 Space 109 (W) 1 109
(Space Name: '2_Bdrm_2_3', Area: 1200 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 205 2_Bdrm_2_3 res lighting interior|Building Unit 205 2_Bdrm_2_3 Space 163 (W) 1 163
(Space Name: '1_Bdrm_7_3', Area: 750 ft^2, Total LPD: 0.16 W/ft^2)
res lighting interior|Building Unit 114 1_Bdrm_7_3 res lighting interior|Building Unit 114 1_Bdrm_7_3 Space 123 (W) 1 123
(Space Name: 'Elevator_2_3', Area: 100 ft^2, Total LPD: 0.0 W/ft^2)
- - - - - -
(Space Name: 'Community_Rm', Area: 1500 ft^2, Total LPD: 0.3 W/ft^2)
community Lights community Lights Definition Spacetype 0.3 (W/ft^2) 1 450
(Space Name: '2_Bdrm_1_4', Area: 1100 ft^2, Total LPD: 0.14 W/ft^2)
res lighting interior|Building Unit 207 2_Bdrm_1_4 res lighting interior|Building Unit 207 2_Bdrm_1_4 Space 154 (W) 1 154
(Space Name: '3_Bdrm_2_2', Area: 1500 ft^2, Total LPD: 0.13 W/ft^2)
res lighting interior|Building Unit 301 3_Bdrm_2_2 res lighting interior|Building Unit 301 3_Bdrm_2_2 Space 190 (W) 1 190
(Space Name: 'Bathrm_1', Area: 150 ft^2, Total LPD: 0.4 W/ft^2)
bathroom Lights bathroom Lights Definition Spacetype 0.4 (W/ft^2) 1 60
(Space Name: 'Coffee_Shop', Area: 1500 ft^2, Total LPD: 0.4 W/ft^2)
coffee Lights coffee Lights Definition Spacetype 0.4 (W/ft^2) 1 600
(Space Name: 'Gym 1', Area: 1050 ft^2, Total LPD: 0.3 W/ft^2)
gym 2 Lights gym 2 Lights Definition Spacetype 0.3 (W/ft^2) 1 315
(Space Name: 'Lt_Retail_3', Area: 1050 ft^2, Total LPD: 0.5 W/ft^2)
retail Lights retail Lights Definition Spacetype 0.5 (W/ft^2) 1 525
(Space Name: 'Lt_Retail_4', Area: 1100 ft^2, Total LPD: 0.5 W/ft^2)
retail Lights retail Lights Definition Spacetype 0.5 (W/ft^2) 1 550
(Space Name: 'Stairwell_1_2', Area: 300 ft^2, Total LPD: 0.4 W/ft^2)
stair Lights stair Lights Definition Spacetype 0.4 (W/ft^2) 1 120
(Space Name: 'Mail_Shipping', Area: 450 ft^2, Total LPD: 0.3 W/ft^2)
mail Lights mail Lights Definition Spacetype 0.3 (W/ft^2) 1 135
(Space Name: 'Office 1', Area: 750 ft^2, Total LPD: 0.3 W/ft^2)
office 2 Lights office 2 Lights Definition Spacetype 0.3 (W/ft^2) 1 225
(Space Name: 'Stairwell_1_3', Area: 300 ft^2, Total LPD: 0.4 W/ft^2)
stair Lights stair Lights Definition Spacetype 0.4 (W/ft^2) 1 120
(Space Name: 'Stairwell_1_4', Area: 300 ft^2, Total LPD: 0.4 W/ft^2)
stair Lights stair Lights Definition Spacetype 0.4 (W/ft^2) 1 120
(Space Name: 'Stairwell_2_2', Area: 300 ft^2, Total LPD: 0.4 W/ft^2)
stair Lights stair Lights Definition Spacetype 0.4 (W/ft^2) 1 120
(Space Name: 'Stairwell_2_3', Area: 300 ft^2, Total LPD: 0.4 W/ft^2)
stair Lights stair Lights Definition Spacetype 0.4 (W/ft^2) 1 120
(Space Name: 'Stairwell_2_4', Area: 300 ft^2, Total LPD: 0.4 W/ft^2)
stair Lights stair Lights Definition Spacetype 0.4 (W/ft^2) 1 120

Space Name Control Name Zone Controlled (type, fraction) Illuminance Setpoint (fc)
Coffee_Shop Coffee_Shop Daylt Sensor 1 Coffee_Shop (primary, 0.3) 28
Coffee_Shop Coffee_Shop Daylt Sensor 2 Coffee_Shop (secondary, 0.3) 28
Lt_Retail_1 Lt_Retail_1 Daylt Sensor 2 Lt_Retail_1 (secondary, 0.2) 51
Lt_Retail_1 Lt_Retail_1 Daylt Sensor 1 Lt_Retail_1 (primary, 0.2) 51
Lt_Retail_2 Lt_Retail_2 Daylt Sensor 1 Lt_Retail_2 (primary, 0.4) 51
Lt_Retail_2 Lt_Retail_2 Daylt Sensor 2 Lt_Retail_2 (secondary, 0.3) 51
Lt_Retail_4 Lt_Retail_4 Daylt Sensor 1 Lt_Retail_4 (primary, 0.4) 51
Lt_Retail_4 Lt_Retail_4 Daylt Sensor 2 Lt_Retail_4 (secondary, 0.3) 51

Plug Loads Summary


Electricity Annual Value (kWh)
InteriorEquipment:Electricity:Zone:0_BDRM_1_2 2038.89
InteriorEquipment:Electricity:Zone:0_BDRM_1_3 4075.0
InteriorEquipment:Electricity:Zone:0_BDRM_1_4 2038.89
InteriorEquipment:Electricity:Zone:0_BDRM_2_2 2038.89
InteriorEquipment:Electricity:Zone:0_BDRM_2_3 4075.0
InteriorEquipment:Electricity:Zone:0_BDRM_2_4 2038.89
InteriorEquipment:Electricity:Zone:0_BDRM_3_2 2038.89
InteriorEquipment:Electricity:Zone:0_BDRM_3_3 4075.0
InteriorEquipment:Electricity:Zone:0_BDRM_3_4 2038.89
InteriorEquipment:Electricity:Zone:0_BDRM_4_2 2038.89
InteriorEquipment:Electricity:Zone:0_BDRM_4_3 4075.0
InteriorEquipment:Electricity:Zone:0_BDRM_4_4 2038.89
InteriorEquipment:Electricity:Zone:1_BDRM_1_2 2411.11
InteriorEquipment:Electricity:Zone:1_BDRM_1_3 4825.0
InteriorEquipment:Electricity:Zone:1_BDRM_1_4 2411.11
InteriorEquipment:Electricity:Zone:1_BDRM_2_2 2411.11
InteriorEquipment:Electricity:Zone:1_BDRM_2_3 4825.0
InteriorEquipment:Electricity:Zone:1_BDRM_2_4 2411.11
InteriorEquipment:Electricity:Zone:1_BDRM_3_2 2411.11
InteriorEquipment:Electricity:Zone:1_BDRM_3_3 4825.0
InteriorEquipment:Electricity:Zone:1_BDRM_3_4 2411.11
InteriorEquipment:Electricity:Zone:1_BDRM_4_2 2455.56
InteriorEquipment:Electricity:Zone:1_BDRM_4_3 4908.33
InteriorEquipment:Electricity:Zone:1_BDRM_4_4 2455.56
InteriorEquipment:Electricity:Zone:1_BDRM_5_2 2455.56
InteriorEquipment:Electricity:Zone:1_BDRM_5_3 4908.33
InteriorEquipment:Electricity:Zone:1_BDRM_5_4 2455.56
InteriorEquipment:Electricity:Zone:1_BDRM_6_2 2411.11
InteriorEquipment:Electricity:Zone:1_BDRM_6_3 4825.0
InteriorEquipment:Electricity:Zone:1_BDRM_6_4 2411.11
InteriorEquipment:Electricity:Zone:1_BDRM_7_2 2455.56
InteriorEquipment:Electricity:Zone:1_BDRM_7_3 4908.33
InteriorEquipment:Electricity:Zone:1_BDRM_7_4 2455.56
InteriorEquipment:Electricity:Zone:2_BDRM_1_2 2883.33
InteriorEquipment:Electricity:Zone:2_BDRM_1_3 5769.44
InteriorEquipment:Electricity:Zone:2_BDRM_1_4 2883.33
InteriorEquipment:Electricity:Zone:2_BDRM_2_2 2911.11
InteriorEquipment:Electricity:Zone:2_BDRM_2_3 5825.0
InteriorEquipment:Electricity:Zone:2_BDRM_2_4 2911.11
InteriorEquipment:Electricity:Zone:2_BDRM_3_2 2897.22
InteriorEquipment:Electricity:Zone:2_BDRM_3_3 5797.22
InteriorEquipment:Electricity:Zone:2_BDRM_3_4 2897.22
InteriorEquipment:Electricity:Zone:3_BDRM_1_3 6658.33
InteriorEquipment:Electricity:Zone:3_BDRM_1_4 3327.78
InteriorEquipment:Electricity:Zone:3_BDRM_2_2 3327.78
InteriorEquipment:Electricity:Zone:ELEVATOR_1_4 2294.44
InteriorEquipment:Electricity:Zone:ELEVATOR_2_4 2294.44
InteriorEquipment:Electricity:Zone:COFFEE_SHOP 1080.56
InteriorEquipment:Electricity:Zone:COMMUNITY_RM 1150.0
InteriorEquipment:Electricity:Zone:GYM 1 6961.11
InteriorEquipment:Electricity:Zone:LOBBY_ENTRY 825.0
InteriorEquipment:Electricity:Zone:OFFICE 1 1683.33
InteriorEquipment:Electricity:Zone:LT_RETAIL_1 1852.78
InteriorEquipment:Electricity:Zone:LT_RETAIL_2 1511.11
InteriorEquipment:Electricity:Zone:LT_RETAIL_3 1441.67
InteriorEquipment:Electricity:Zone:LT_RETAIL_4 1511.11

Equipment Name Definition Load (units) Inheritance Level Multiplier Total Load (W)
(Space Name: 0_Bdrm_1_2, Area: 450 ft^2)
res cw|Building Unit 001 res cw|Building Unit 001 3594 (W) space 1.0 3594
res refrig|Building Unit 001 res refrig|Building Unit 001 52 (W) space 1.0 52
res dw|Building Unit 001 res dw|Building Unit 001 5367 (W) space 1.0 5367
res cd electric|Building Unit 001 res cd electric|Building Unit 001 40138 (W) space 1.0 40138
res range electric|Building Unit 001 res range electric|Building Unit 001 106 (W) space 1.0 106
res misc plug loads|Building Unit 001|0_Bdrm_1_2 res misc plug loads|Building Unit 001|0_Bdrm_1_2 225 (W) space 1.0 225
(Space Name: 0_Bdrm_1_3, Area: 450 ft^2)
res cw|Building Unit 005 res cw|Building Unit 005 3594 (W) space 1.0 3594
res refrig|Building Unit 005 res refrig|Building Unit 005 52 (W) space 1.0 52
res dw|Building Unit 005 res dw|Building Unit 005 5367 (W) space 1.0 5367
res cd electric|Building Unit 005 res cd electric|Building Unit 005 40138 (W) space 1.0 40138
res range electric|Building Unit 005 res range electric|Building Unit 005 106 (W) space 1.0 106
res misc plug loads|Building Unit 005|0_Bdrm_1_3 res misc plug loads|Building Unit 005|0_Bdrm_1_3 225 (W) space 1.0 225
(Space Name: 0_Bdrm_1_4, Area: 450 ft^2)
res cw|Building Unit 009 res cw|Building Unit 009 3594 (W) space 1.0 3594
res refrig|Building Unit 009 res refrig|Building Unit 009 52 (W) space 1.0 52
res dw|Building Unit 009 res dw|Building Unit 009 5367 (W) space 1.0 5367
res cd electric|Building Unit 009 res cd electric|Building Unit 009 40138 (W) space 1.0 40138
res range electric|Building Unit 009 res range electric|Building Unit 009 106 (W) space 1.0 106
res misc plug loads|Building Unit 009|0_Bdrm_1_4 res misc plug loads|Building Unit 009|0_Bdrm_1_4 225 (W) space 1.0 225
(Space Name: 0_Bdrm_2_2, Area: 450 ft^2)
res cw|Building Unit 002 res cw|Building Unit 002 3594 (W) space 1.0 3594
res refrig|Building Unit 002 res refrig|Building Unit 002 52 (W) space 1.0 52
res dw|Building Unit 002 res dw|Building Unit 002 5367 (W) space 1.0 5367
res cd electric|Building Unit 002 res cd electric|Building Unit 002 40138 (W) space 1.0 40138
res range electric|Building Unit 002 res range electric|Building Unit 002 106 (W) space 1.0 106
res misc plug loads|Building Unit 002|0_Bdrm_2_2 res misc plug loads|Building Unit 002|0_Bdrm_2_2 225 (W) space 1.0 225
(Space Name: 0_Bdrm_2_3, Area: 450 ft^2)
res cw|Building Unit 006 res cw|Building Unit 006 3594 (W) space 1.0 3594
res refrig|Building Unit 006 res refrig|Building Unit 006 52 (W) space 1.0 52
res dw|Building Unit 006 res dw|Building Unit 006 5367 (W) space 1.0 5367
res cd electric|Building Unit 006 res cd electric|Building Unit 006 40138 (W) space 1.0 40138
res range electric|Building Unit 006 res range electric|Building Unit 006 106 (W) space 1.0 106
res misc plug loads|Building Unit 006|0_Bdrm_2_3 res misc plug loads|Building Unit 006|0_Bdrm_2_3 225 (W) space 1.0 225
(Space Name: 0_Bdrm_2_4, Area: 450 ft^2)
res cw|Building Unit 010 res cw|Building Unit 010 3594 (W) space 1.0 3594
res refrig|Building Unit 010 res refrig|Building Unit 010 52 (W) space 1.0 52
res dw|Building Unit 010 res dw|Building Unit 010 5367 (W) space 1.0 5367
res cd electric|Building Unit 010 res cd electric|Building Unit 010 40138 (W) space 1.0 40138
res range electric|Building Unit 010 res range electric|Building Unit 010 106 (W) space 1.0 106
res misc plug loads|Building Unit 010|0_Bdrm_2_4 res misc plug loads|Building Unit 010|0_Bdrm_2_4 225 (W) space 1.0 225
(Space Name: 0_Bdrm_3_2, Area: 450 ft^2)
res cw|Building Unit 003 res cw|Building Unit 003 3594 (W) space 1.0 3594
res refrig|Building Unit 003 res refrig|Building Unit 003 52 (W) space 1.0 52
res dw|Building Unit 003 res dw|Building Unit 003 5367 (W) space 1.0 5367
res cd electric|Building Unit 003 res cd electric|Building Unit 003 40138 (W) space 1.0 40138
res range electric|Building Unit 003 res range electric|Building Unit 003 106 (W) space 1.0 106
res misc plug loads|Building Unit 003|0_Bdrm_3_2 res misc plug loads|Building Unit 003|0_Bdrm_3_2 225 (W) space 1.0 225
(Space Name: 0_Bdrm_3_3, Area: 450 ft^2)
res cw|Building Unit 007 res cw|Building Unit 007 3594 (W) space 1.0 3594
res refrig|Building Unit 007 res refrig|Building Unit 007 52 (W) space 1.0 52
res dw|Building Unit 007 res dw|Building Unit 007 5367 (W) space 1.0 5367
res cd electric|Building Unit 007 res cd electric|Building Unit 007 40138 (W) space 1.0 40138
res range electric|Building Unit 007 res range electric|Building Unit 007 106 (W) space 1.0 106
res misc plug loads|Building Unit 007|0_Bdrm_3_3 res misc plug loads|Building Unit 007|0_Bdrm_3_3 225 (W) space 1.0 225
(Space Name: 0_Bdrm_3_4, Area: 450 ft^2)
res cw|Building Unit 011 res cw|Building Unit 011 3594 (W) space 1.0 3594
res refrig|Building Unit 011 res refrig|Building Unit 011 52 (W) space 1.0 52
res dw|Building Unit 011 res dw|Building Unit 011 5367 (W) space 1.0 5367
res cd electric|Building Unit 011 res cd electric|Building Unit 011 40138 (W) space 1.0 40138
res range electric|Building Unit 011 res range electric|Building Unit 011 106 (W) space 1.0 106
res misc plug loads|Building Unit 011|0_Bdrm_3_4 res misc plug loads|Building Unit 011|0_Bdrm_3_4 225 (W) space 1.0 225
(Space Name: 0_Bdrm_4_2, Area: 450 ft^2)
res cw|Building Unit 004 res cw|Building Unit 004 3594 (W) space 1.0 3594
res refrig|Building Unit 004 res refrig|Building Unit 004 52 (W) space 1.0 52
res dw|Building Unit 004 res dw|Building Unit 004 5367 (W) space 1.0 5367
res cd electric|Building Unit 004 res cd electric|Building Unit 004 40138 (W) space 1.0 40138
res range electric|Building Unit 004 res range electric|Building Unit 004 106 (W) space 1.0 106
res misc plug loads|Building Unit 004|0_Bdrm_4_2 res misc plug loads|Building Unit 004|0_Bdrm_4_2 225 (W) space 1.0 225
(Space Name: 0_Bdrm_4_3, Area: 450 ft^2)
res cw|Building Unit 008 res cw|Building Unit 008 3594 (W) space 1.0 3594
res refrig|Building Unit 008 res refrig|Building Unit 008 52 (W) space 1.0 52
res dw|Building Unit 008 res dw|Building Unit 008 5367 (W) space 1.0 5367
res cd electric|Building Unit 008 res cd electric|Building Unit 008 40138 (W) space 1.0 40138
res range electric|Building Unit 008 res range electric|Building Unit 008 106 (W) space 1.0 106
res misc plug loads|Building Unit 008|0_Bdrm_4_3 res misc plug loads|Building Unit 008|0_Bdrm_4_3 225 (W) space 1.0 225
(Space Name: 0_Bdrm_4_4, Area: 450 ft^2)
res cw|Building Unit 012 res cw|Building Unit 012 3594 (W) space 1.0 3594
res refrig|Building Unit 012 res refrig|Building Unit 012 52 (W) space 1.0 52
res dw|Building Unit 012 res dw|Building Unit 012 5367 (W) space 1.0 5367
res cd electric|Building Unit 012 res cd electric|Building Unit 012 40138 (W) space 1.0 40138
res range electric|Building Unit 012 res range electric|Building Unit 012 106 (W) space 1.0 106
res misc plug loads|Building Unit 012|0_Bdrm_4_4 res misc plug loads|Building Unit 012|0_Bdrm_4_4 225 (W) space 1.0 225
(Space Name: 1_Bdrm_1_2, Area: 600 ft^2)
res cw|Building Unit 101 res cw|Building Unit 101 4792 (W) space 1.0 4792
res refrig|Building Unit 101 res refrig|Building Unit 101 52 (W) space 1.0 52
res dw|Building Unit 101 res dw|Building Unit 101 7156 (W) space 1.0 7156
res cd electric|Building Unit 101 res cd electric|Building Unit 101 53517 (W) space 1.0 53517
res range electric|Building Unit 101 res range electric|Building Unit 101 141 (W) space 1.0 141
res misc plug loads|Building Unit 101|1_Bdrm_1_2 res misc plug loads|Building Unit 101|1_Bdrm_1_2 266 (W) space 1.0 266
(Space Name: 1_Bdrm_1_3, Area: 600 ft^2)
res refrig|Building Unit 108 res refrig|Building Unit 108 52 (W) space 1.0 52
res cw|Building Unit 108 res cw|Building Unit 108 4792 (W) space 1.0 4792
res dw|Building Unit 108 res dw|Building Unit 108 7156 (W) space 1.0 7156
res cd electric|Building Unit 108 res cd electric|Building Unit 108 53517 (W) space 1.0 53517
res range electric|Building Unit 108 res range electric|Building Unit 108 141 (W) space 1.0 141
res misc plug loads|Building Unit 108|1_Bdrm_1_3 res misc plug loads|Building Unit 108|1_Bdrm_1_3 266 (W) space 1.0 266
(Space Name: 1_Bdrm_1_4, Area: 600 ft^2)
res refrig|Building Unit 115 res refrig|Building Unit 115 52 (W) space 1.0 52
res cw|Building Unit 115 res cw|Building Unit 115 4792 (W) space 1.0 4792
res dw|Building Unit 115 res dw|Building Unit 115 7156 (W) space 1.0 7156
res cd electric|Building Unit 115 res cd electric|Building Unit 115 53517 (W) space 1.0 53517
res range electric|Building Unit 115 res range electric|Building Unit 115 141 (W) space 1.0 141
res misc plug loads|Building Unit 115|1_Bdrm_1_4 res misc plug loads|Building Unit 115|1_Bdrm_1_4 266 (W) space 1.0 266
(Space Name: 1_Bdrm_2_2, Area: 600 ft^2)
res cw|Building Unit 102 res cw|Building Unit 102 4792 (W) space 1.0 4792
res refrig|Building Unit 102 res refrig|Building Unit 102 52 (W) space 1.0 52
res dw|Building Unit 102 res dw|Building Unit 102 7156 (W) space 1.0 7156
res cd electric|Building Unit 102 res cd electric|Building Unit 102 53517 (W) space 1.0 53517
res range electric|Building Unit 102 res range electric|Building Unit 102 141 (W) space 1.0 141
res misc plug loads|Building Unit 102|1_Bdrm_2_2 res misc plug loads|Building Unit 102|1_Bdrm_2_2 266 (W) space 1.0 266
(Space Name: 1_Bdrm_2_3, Area: 600 ft^2)
res refrig|Building Unit 109 res refrig|Building Unit 109 52 (W) space 1.0 52
res cw|Building Unit 109 res cw|Building Unit 109 4792 (W) space 1.0 4792
res dw|Building Unit 109 res dw|Building Unit 109 7156 (W) space 1.0 7156
res cd electric|Building Unit 109 res cd electric|Building Unit 109 53517 (W) space 1.0 53517
res range electric|Building Unit 109 res range electric|Building Unit 109 141 (W) space 1.0 141
res misc plug loads|Building Unit 109|1_Bdrm_2_3 res misc plug loads|Building Unit 109|1_Bdrm_2_3 266 (W) space 1.0 266
(Space Name: 1_Bdrm_2_4, Area: 600 ft^2)
res refrig|Building Unit 116 res refrig|Building Unit 116 52 (W) space 1.0 52
res cw|Building Unit 116 res cw|Building Unit 116 4792 (W) space 1.0 4792
res dw|Building Unit 116 res dw|Building Unit 116 7156 (W) space 1.0 7156
res cd electric|Building Unit 116 res cd electric|Building Unit 116 53517 (W) space 1.0 53517
res range electric|Building Unit 116 res range electric|Building Unit 116 141 (W) space 1.0 141
res misc plug loads|Building Unit 116|1_Bdrm_2_4 res misc plug loads|Building Unit 116|1_Bdrm_2_4 266 (W) space 1.0 266
(Space Name: 1_Bdrm_3_2, Area: 600 ft^2)
res cw|Building Unit 103 res cw|Building Unit 103 4792 (W) space 1.0 4792
res refrig|Building Unit 103 res refrig|Building Unit 103 52 (W) space 1.0 52
res dw|Building Unit 103 res dw|Building Unit 103 7156 (W) space 1.0 7156
res cd electric|Building Unit 103 res cd electric|Building Unit 103 53517 (W) space 1.0 53517
res range electric|Building Unit 103 res range electric|Building Unit 103 141 (W) space 1.0 141
res misc plug loads|Building Unit 103|1_Bdrm_3_2 res misc plug loads|Building Unit 103|1_Bdrm_3_2 266 (W) space 1.0 266
(Space Name: 1_Bdrm_3_3, Area: 600 ft^2)
res refrig|Building Unit 110 res refrig|Building Unit 110 52 (W) space 1.0 52
res cw|Building Unit 110 res cw|Building Unit 110 4792 (W) space 1.0 4792
res dw|Building Unit 110 res dw|Building Unit 110 7156 (W) space 1.0 7156
res cd electric|Building Unit 110 res cd electric|Building Unit 110 53517 (W) space 1.0 53517
res range electric|Building Unit 110 res range electric|Building Unit 110 141 (W) space 1.0 141
res misc plug loads|Building Unit 110|1_Bdrm_3_3 res misc plug loads|Building Unit 110|1_Bdrm_3_3 266 (W) space 1.0 266
(Space Name: 1_Bdrm_3_4, Area: 600 ft^2)
res refrig|Building Unit 117 res refrig|Building Unit 117 52 (W) space 1.0 52
res cw|Building Unit 117 res cw|Building Unit 117 4792 (W) space 1.0 4792
res dw|Building Unit 117 res dw|Building Unit 117 7156 (W) space 1.0 7156
res cd electric|Building Unit 117 res cd electric|Building Unit 117 53517 (W) space 1.0 53517
res range electric|Building Unit 117 res range electric|Building Unit 117 141 (W) space 1.0 141
res misc plug loads|Building Unit 117|1_Bdrm_3_4 res misc plug loads|Building Unit 117|1_Bdrm_3_4 266 (W) space 1.0 266
(Space Name: 1_Bdrm_4_2, Area: 750 ft^2)
res refrig|Building Unit 104 res refrig|Building Unit 104 52 (W) space 1.0 52
res dw|Building Unit 104 res dw|Building Unit 104 7156 (W) space 1.0 7156
res cw|Building Unit 104 res cw|Building Unit 104 4792 (W) space 1.0 4792
res cd electric|Building Unit 104 res cd electric|Building Unit 104 53517 (W) space 1.0 53517
res range electric|Building Unit 104 res range electric|Building Unit 104 141 (W) space 1.0 141
res misc plug loads|Building Unit 104|1_Bdrm_4_2 res misc plug loads|Building Unit 104|1_Bdrm_4_2 274 (W) space 1.0 274
(Space Name: 1_Bdrm_4_3, Area: 750 ft^2)
res refrig|Building Unit 111 res refrig|Building Unit 111 52 (W) space 1.0 52
res cw|Building Unit 111 res cw|Building Unit 111 4792 (W) space 1.0 4792
res dw|Building Unit 111 res dw|Building Unit 111 7156 (W) space 1.0 7156
res cd electric|Building Unit 111 res cd electric|Building Unit 111 53517 (W) space 1.0 53517
res range electric|Building Unit 111 res range electric|Building Unit 111 141 (W) space 1.0 141
res misc plug loads|Building Unit 111|1_Bdrm_4_3 res misc plug loads|Building Unit 111|1_Bdrm_4_3 274 (W) space 1.0 274
(Space Name: 1_Bdrm_4_4, Area: 750 ft^2)
res refrig|Building Unit 118 res refrig|Building Unit 118 52 (W) space 1.0 52
res cw|Building Unit 118 res cw|Building Unit 118 4792 (W) space 1.0 4792
res dw|Building Unit 118 res dw|Building Unit 118 7156 (W) space 1.0 7156
res cd electric|Building Unit 118 res cd electric|Building Unit 118 53517 (W) space 1.0 53517
res range electric|Building Unit 118 res range electric|Building Unit 118 141 (W) space 1.0 141
res misc plug loads|Building Unit 118|1_Bdrm_4_4 res misc plug loads|Building Unit 118|1_Bdrm_4_4 274 (W) space 1.0 274
(Space Name: 1_Bdrm_5_2, Area: 750 ft^2)
res refrig|Building Unit 105 res refrig|Building Unit 105 52 (W) space 1.0 52
res dw|Building Unit 105 res dw|Building Unit 105 7156 (W) space 1.0 7156
res cw|Building Unit 105 res cw|Building Unit 105 4792 (W) space 1.0 4792
res cd electric|Building Unit 105 res cd electric|Building Unit 105 53517 (W) space 1.0 53517
res range electric|Building Unit 105 res range electric|Building Unit 105 141 (W) space 1.0 141
res misc plug loads|Building Unit 105|1_Bdrm_5_2 res misc plug loads|Building Unit 105|1_Bdrm_5_2 274 (W) space 1.0 274
(Space Name: 1_Bdrm_5_3, Area: 750 ft^2)
res refrig|Building Unit 112 res refrig|Building Unit 112 52 (W) space 1.0 52
res cw|Building Unit 112 res cw|Building Unit 112 4792 (W) space 1.0 4792
res dw|Building Unit 112 res dw|Building Unit 112 7156 (W) space 1.0 7156
res cd electric|Building Unit 112 res cd electric|Building Unit 112 53517 (W) space 1.0 53517
res range electric|Building Unit 112 res range electric|Building Unit 112 141 (W) space 1.0 141
res misc plug loads|Building Unit 112|1_Bdrm_5_3 res misc plug loads|Building Unit 112|1_Bdrm_5_3 274 (W) space 1.0 274
(Space Name: 1_Bdrm_5_4, Area: 750 ft^2)
res refrig|Building Unit 119 res refrig|Building Unit 119 52 (W) space 1.0 52
res cw|Building Unit 119 res cw|Building Unit 119 4792 (W) space 1.0 4792
res dw|Building Unit 119 res dw|Building Unit 119 7156 (W) space 1.0 7156
res cd electric|Building Unit 119 res cd electric|Building Unit 119 53517 (W) space 1.0 53517
res range electric|Building Unit 119 res range electric|Building Unit 119 141 (W) space 1.0 141
res misc plug loads|Building Unit 119|1_Bdrm_5_4 res misc plug loads|Building Unit 119|1_Bdrm_5_4 274 (W) space 1.0 274
(Space Name: 1_Bdrm_6_2, Area: 600 ft^2)
res refrig|Building Unit 106 res refrig|Building Unit 106 52 (W) space 1.0 52
res cw|Building Unit 106 res cw|Building Unit 106 4792 (W) space 1.0 4792
res dw|Building Unit 106 res dw|Building Unit 106 7156 (W) space 1.0 7156
res cd electric|Building Unit 106 res cd electric|Building Unit 106 53517 (W) space 1.0 53517
res range electric|Building Unit 106 res range electric|Building Unit 106 141 (W) space 1.0 141
res misc plug loads|Building Unit 106|1_Bdrm_6_2 res misc plug loads|Building Unit 106|1_Bdrm_6_2 266 (W) space 1.0 266
(Space Name: 1_Bdrm_6_3, Area: 600 ft^2)
res refrig|Building Unit 113 res refrig|Building Unit 113 52 (W) space 1.0 52
res cw|Building Unit 113 res cw|Building Unit 113 4792 (W) space 1.0 4792
res dw|Building Unit 113 res dw|Building Unit 113 7156 (W) space 1.0 7156
res cd electric|Building Unit 113 res cd electric|Building Unit 113 53517 (W) space 1.0 53517
res range electric|Building Unit 113 res range electric|Building Unit 113 141 (W) space 1.0 141
res misc plug loads|Building Unit 113|1_Bdrm_6_3 res misc plug loads|Building Unit 113|1_Bdrm_6_3 266 (W) space 1.0 266
(Space Name: 1_Bdrm_6_4, Area: 600 ft^2)
res refrig|Building Unit 120 res refrig|Building Unit 120 52 (W) space 1.0 52
res cw|Building Unit 120 res cw|Building Unit 120 4792 (W) space 1.0 4792
res dw|Building Unit 120 res dw|Building Unit 120 7156 (W) space 1.0 7156
res cd electric|Building Unit 120 res cd electric|Building Unit 120 53517 (W) space 1.0 53517
res range electric|Building Unit 120 res range electric|Building Unit 120 141 (W) space 1.0 141
res misc plug loads|Building Unit 120|1_Bdrm_6_4 res misc plug loads|Building Unit 120|1_Bdrm_6_4 266 (W) space 1.0 266
(Space Name: 1_Bdrm_7_2, Area: 750 ft^2)
res refrig|Building Unit 107 res refrig|Building Unit 107 52 (W) space 1.0 52
res cw|Building Unit 107 res cw|Building Unit 107 4792 (W) space 1.0 4792
res dw|Building Unit 107 res dw|Building Unit 107 7156 (W) space 1.0 7156
res cd electric|Building Unit 107 res cd electric|Building Unit 107 53517 (W) space 1.0 53517
res range electric|Building Unit 107 res range electric|Building Unit 107 141 (W) space 1.0 141
res misc plug loads|Building Unit 107|1_Bdrm_7_2 res misc plug loads|Building Unit 107|1_Bdrm_7_2 274 (W) space 1.0 274
(Space Name: 1_Bdrm_7_3, Area: 750 ft^2)
res refrig|Building Unit 114 res refrig|Building Unit 114 52 (W) space 1.0 52
res cw|Building Unit 114 res cw|Building Unit 114 4792 (W) space 1.0 4792
res dw|Building Unit 114 res dw|Building Unit 114 7156 (W) space 1.0 7156
res cd electric|Building Unit 114 res cd electric|Building Unit 114 53517 (W) space 1.0 53517
res range electric|Building Unit 114 res range electric|Building Unit 114 141 (W) space 1.0 141
res misc plug loads|Building Unit 114|1_Bdrm_7_3 res misc plug loads|Building Unit 114|1_Bdrm_7_3 274 (W) space 1.0 274
(Space Name: 1_Bdrm_7_4, Area: 750 ft^2)
res refrig|Building Unit 121 res refrig|Building Unit 121 52 (W) space 1.0 52
res cw|Building Unit 121 res cw|Building Unit 121 4792 (W) space 1.0 4792
res dw|Building Unit 121 res dw|Building Unit 121 7156 (W) space 1.0 7156
res cd electric|Building Unit 121 res cd electric|Building Unit 121 53517 (W) space 1.0 53517
res range electric|Building Unit 121 res range electric|Building Unit 121 141 (W) space 1.0 141
res misc plug loads|Building Unit 121|1_Bdrm_7_4 res misc plug loads|Building Unit 121|1_Bdrm_7_4 274 (W) space 1.0 274
(Space Name: 2_Bdrm_1_2, Area: 1100 ft^2)
res refrig|Building Unit 201 res refrig|Building Unit 201 52 (W) space 1.0 52
res cw|Building Unit 201 res cw|Building Unit 201 5266 (W) space 1.0 5266
res dw|Building Unit 201 res dw|Building Unit 201 6820 (W) space 1.0 6820
res cd electric|Building Unit 201 res cd electric|Building Unit 201 66897 (W) space 1.0 66897
res range electric|Building Unit 201 res range electric|Building Unit 201 177 (W) space 1.0 177
res misc plug loads|Building Unit 201|2_Bdrm_1_2 res misc plug loads|Building Unit 201|2_Bdrm_1_2 324 (W) space 1.0 324
(Space Name: 2_Bdrm_1_3, Area: 1100 ft^2)
res refrig|Building Unit 204 res refrig|Building Unit 204 52 (W) space 1.0 52
res cw|Building Unit 204 res cw|Building Unit 204 5266 (W) space 1.0 5266
res dw|Building Unit 204 res dw|Building Unit 204 6820 (W) space 1.0 6820
res cd electric|Building Unit 204 res cd electric|Building Unit 204 66897 (W) space 1.0 66897
res range electric|Building Unit 204 res range electric|Building Unit 204 177 (W) space 1.0 177
res misc plug loads|Building Unit 204|2_Bdrm_1_3 res misc plug loads|Building Unit 204|2_Bdrm_1_3 324 (W) space 1.0 324
(Space Name: 2_Bdrm_1_4, Area: 1100 ft^2)
res refrig|Building Unit 207 res refrig|Building Unit 207 52 (W) space 1.0 52
res cw|Building Unit 207 res cw|Building Unit 207 5266 (W) space 1.0 5266
res dw|Building Unit 207 res dw|Building Unit 207 6820 (W) space 1.0 6820
res cd electric|Building Unit 207 res cd electric|Building Unit 207 66897 (W) space 1.0 66897
res range electric|Building Unit 207 res range electric|Building Unit 207 177 (W) space 1.0 177
res misc plug loads|Building Unit 207|2_Bdrm_1_4 res misc plug loads|Building Unit 207|2_Bdrm_1_4 324 (W) space 1.0 324
(Space Name: 2_Bdrm_2_2, Area: 1200 ft^2)
res refrig|Building Unit 202 res refrig|Building Unit 202 52 (W) space 1.0 52
res cw|Building Unit 202 res cw|Building Unit 202 5266 (W) space 1.0 5266
res dw|Building Unit 202 res dw|Building Unit 202 6820 (W) space 1.0 6820
res cd electric|Building Unit 202 res cd electric|Building Unit 202 66897 (W) space 1.0 66897
res range electric|Building Unit 202 res range electric|Building Unit 202 177 (W) space 1.0 177
res misc plug loads|Building Unit 202|2_Bdrm_2_2 res misc plug loads|Building Unit 202|2_Bdrm_2_2 329 (W) space 1.0 329
(Space Name: 2_Bdrm_2_3, Area: 1200 ft^2)
res refrig|Building Unit 205 res refrig|Building Unit 205 52 (W) space 1.0 52
res cw|Building Unit 205 res cw|Building Unit 205 5266 (W) space 1.0 5266
res dw|Building Unit 205 res dw|Building Unit 205 6820 (W) space 1.0 6820
res cd electric|Building Unit 205 res cd electric|Building Unit 205 66897 (W) space 1.0 66897
res range electric|Building Unit 205 res range electric|Building Unit 205 177 (W) space 1.0 177
res misc plug loads|Building Unit 205|2_Bdrm_2_3 res misc plug loads|Building Unit 205|2_Bdrm_2_3 329 (W) space 1.0 329
(Space Name: 2_Bdrm_2_4, Area: 1200 ft^2)
res refrig|Building Unit 208 res refrig|Building Unit 208 52 (W) space 1.0 52
res cw|Building Unit 208 res cw|Building Unit 208 5266 (W) space 1.0 5266
res dw|Building Unit 208 res dw|Building Unit 208 6820 (W) space 1.0 6820
res cd electric|Building Unit 208 res cd electric|Building Unit 208 66897 (W) space 1.0 66897
res range electric|Building Unit 208 res range electric|Building Unit 208 177 (W) space 1.0 177
res misc plug loads|Building Unit 208|2_Bdrm_2_4 res misc plug loads|Building Unit 208|2_Bdrm_2_4 329 (W) space 1.0 329
(Space Name: 2_Bdrm_3_2, Area: 1150 ft^2)
res refrig|Building Unit 203 res refrig|Building Unit 203 52 (W) space 1.0 52
res cw|Building Unit 203 res cw|Building Unit 203 5266 (W) space 1.0 5266
res dw|Building Unit 203 res dw|Building Unit 203 6820 (W) space 1.0 6820
res cd electric|Building Unit 203 res cd electric|Building Unit 203 66897 (W) space 1.0 66897
res range electric|Building Unit 203 res range electric|Building Unit 203 177 (W) space 1.0 177
res misc plug loads|Building Unit 203|2_Bdrm_3_2 res misc plug loads|Building Unit 203|2_Bdrm_3_2 327 (W) space 1.0 327
(Space Name: 2_Bdrm_3_3, Area: 1150 ft^2)
res refrig|Building Unit 206 res refrig|Building Unit 206 52 (W) space 1.0 52
res cw|Building Unit 206 res cw|Building Unit 206 5266 (W) space 1.0 5266
res dw|Building Unit 206 res dw|Building Unit 206 6820 (W) space 1.0 6820
res cd electric|Building Unit 206 res cd electric|Building Unit 206 66897 (W) space 1.0 66897
res range electric|Building Unit 206 res range electric|Building Unit 206 177 (W) space 1.0 177
res misc plug loads|Building Unit 206|2_Bdrm_3_3 res misc plug loads|Building Unit 206|2_Bdrm_3_3 327 (W) space 1.0 327
(Space Name: 2_Bdrm_3_4, Area: 1150 ft^2)
res refrig|Building Unit 209 res refrig|Building Unit 209 52 (W) space 1.0 52
res cw|Building Unit 209 res cw|Building Unit 209 5266 (W) space 1.0 5266
res dw|Building Unit 209 res dw|Building Unit 209 6820 (W) space 1.0 6820
res cd electric|Building Unit 209 res cd electric|Building Unit 209 66897 (W) space 1.0 66897
res range electric|Building Unit 209 res range electric|Building Unit 209 177 (W) space 1.0 177
res misc plug loads|Building Unit 209|2_Bdrm_3_4 res misc plug loads|Building Unit 209|2_Bdrm_3_4 327 (W) space 1.0 327
(Space Name: 3_Bdrm_1_3, Area: 1500 ft^2)
res refrig|Building Unit 302 res refrig|Building Unit 302 52 (W) space 1.0 52
res cw|Building Unit 302 res cw|Building Unit 302 5597 (W) space 1.0 5597
res dw|Building Unit 302 res dw|Building Unit 302 7242 (W) space 1.0 7242
res cd electric|Building Unit 302 res cd electric|Building Unit 302 80276 (W) space 1.0 80276
res range electric|Building Unit 302 res range electric|Building Unit 302 212 (W) space 1.0 212
res misc plug loads|Building Unit 302|3_Bdrm_1_3 res misc plug loads|Building Unit 302|3_Bdrm_1_3 378 (W) space 1.0 378
(Space Name: 3_Bdrm_1_4, Area: 1500 ft^2)
res refrig|Building Unit 303 res refrig|Building Unit 303 52 (W) space 1.0 52
res cw|Building Unit 303 res cw|Building Unit 303 5597 (W) space 1.0 5597
res dw|Building Unit 303 res dw|Building Unit 303 7242 (W) space 1.0 7242
res cd electric|Building Unit 303 res cd electric|Building Unit 303 80276 (W) space 1.0 80276
res range electric|Building Unit 303 res range electric|Building Unit 303 212 (W) space 1.0 212
res misc plug loads|Building Unit 303|3_Bdrm_1_4 res misc plug loads|Building Unit 303|3_Bdrm_1_4 378 (W) space 1.0 378
(Space Name: 3_Bdrm_2_2, Area: 1500 ft^2)
res refrig|Building Unit 301 res refrig|Building Unit 301 52 (W) space 1.0 52
res cw|Building Unit 301 res cw|Building Unit 301 5597 (W) space 1.0 5597
res dw|Building Unit 301 res dw|Building Unit 301 7242 (W) space 1.0 7242
res cd electric|Building Unit 301 res cd electric|Building Unit 301 80276 (W) space 1.0 80276
res range electric|Building Unit 301 res range electric|Building Unit 301 212 (W) space 1.0 212
res misc plug loads|Building Unit 301|3_Bdrm_2_2 res misc plug loads|Building Unit 301|3_Bdrm_2_2 378 (W) space 1.0 378
(Space Name: Coffee_Shop, Area: 1500 ft^2)
coffee Elec Equip coffee Elec Equip Definition 0.5 (W/ft^2) spacetype 1.0 750
(Space Name: Community_Rm, Area: 1500 ft^2)
community Elec Equip community Elec Equip Definition 0.57 (W/ft^2) spacetype 1.0 861
(Space Name: Elevator_1_4, Area: 100 ft^2)
Elevator_1_4 Elevator Fans Elevator Fan 31 (W) space 1.0 31
Elevator_1_4 Elevator Lift Motors Elevator Lift Motor 20370 (W) space 1.0 20370
Elevator_1_4 Elevator Lights Elevator Lights 32 (W) space 1.0 32
(Space Name: Elevator_2_4, Area: 100 ft^2)
Elevator_2_4 Elevator Lights Elevator Lights 32 (W) space 1.0 32
Elevator_2_4 Elevator Fans Elevator Fan 31 (W) space 1.0 31
Elevator_2_4 Elevator Lift Motors Elevator Lift Motor 20370 (W) space 1.0 20370
(Space Name: Gym 1, Area: 1050 ft^2)
gym 2 Elec Equip gym 2 Elec Equip Definition 1.73 (W/ft^2) spacetype 1.0 1816
(Space Name: Lobby_Entry, Area: 600 ft^2)
lobby Elec Equip lobby Elec Equip Definition 0.3 (W/ft^2) spacetype 1.0 180
(Space Name: Lt_Retail_1, Area: 1350 ft^2)
retail Elec Equip retail Elec Equip Definition 0.3 (W/ft^2) spacetype 1.0 405
(Space Name: Lt_Retail_2, Area: 1100 ft^2)
retail Elec Equip retail Elec Equip Definition 0.3 (W/ft^2) spacetype 1.0 330
(Space Name: Lt_Retail_3, Area: 1050 ft^2)
retail Elec Equip retail Elec Equip Definition 0.3 (W/ft^2) spacetype 1.0 315
(Space Name: Lt_Retail_4, Area: 1100 ft^2)
retail Elec Equip retail Elec Equip Definition 0.3 (W/ft^2) spacetype 1.0 330
(Space Name: Office 1, Area: 750 ft^2)
office 2 Elec Equip office 2 Elec Equip Definition 0.62 (W/ft^2) spacetype 1.0 465

Exterior Lighting


Description Total Power (W) Astronomical Schedule Name Annual Consumption (kWh)
BUILDING FACADES 371.0 AstronomicalClock - 872.22
DRIVE THROUGH WINDOWS 48.0 AstronomicalClock - 180.56
ENTRY CANOPIES 288.0 AstronomicalClock - 1083.33
MAIN ENTRIES 168.0 AstronomicalClock - 633.33
OTHER DOORS 500.49 AstronomicalClock - 1883.33
PARKING AREAS AND DRIVES 0.0 AstronomicalClock - 0.0
Exterior Lighting Total 1375.49 4655.56

Water Use Equipment


Instance Plant Loop Definition Space Peak Flow Rate (gal/min) Flow Rate Schedule Target Temp Range (F)
res bath dist|Building Unit 001=0.0 Service Hot Water Loop res bath dist|Building Unit 001=0.0 0_Bdrm_1_2 0.00 res bath schedule can't inspect schedule.
res bath dist|Building Unit 002=0.0 Service Hot Water Loop res bath dist|Building Unit 002=0.0 0_Bdrm_2_2 0.00 res bath schedule 1 can't inspect schedule.
res bath dist|Building Unit 003=0.0 Service Hot Water Loop res bath dist|Building Unit 003=0.0 0_Bdrm_3_2 0.00 res bath schedule 2 can't inspect schedule.
res bath dist|Building Unit 004=0.0 Service Hot Water Loop res bath dist|Building Unit 004=0.0 0_Bdrm_4_2 0.00 res bath schedule 3 can't inspect schedule.
res bath dist|Building Unit 005=0.0 Service Hot Water Loop res bath dist|Building Unit 005=0.0 0_Bdrm_1_3 0.00 res bath schedule 4 can't inspect schedule.
res bath dist|Building Unit 006=0.0 Service Hot Water Loop res bath dist|Building Unit 006=0.0 0_Bdrm_2_3 0.00 res bath schedule 5 can't inspect schedule.
res bath dist|Building Unit 007=0.0 Service Hot Water Loop res bath dist|Building Unit 007=0.0 0_Bdrm_3_3 0.00 res bath schedule 6 can't inspect schedule.
res bath dist|Building Unit 008=0.0 Service Hot Water Loop res bath dist|Building Unit 008=0.0 0_Bdrm_4_3 0.00 res bath schedule 7 can't inspect schedule.
res bath dist|Building Unit 009=0.0 Service Hot Water Loop res bath dist|Building Unit 009=0.0 0_Bdrm_1_4 0.00 res bath schedule 8 can't inspect schedule.
res bath dist|Building Unit 010=0.0 Service Hot Water Loop res bath dist|Building Unit 010=0.0 0_Bdrm_2_4 0.00 res bath schedule 9 can't inspect schedule.
res bath dist|Building Unit 011=0.0 Service Hot Water Loop res bath dist|Building Unit 011=0.0 0_Bdrm_3_4 0.00 res bath schedule 10 can't inspect schedule.
res bath dist|Building Unit 012=0.0 Service Hot Water Loop res bath dist|Building Unit 012=0.0 0_Bdrm_4_4 0.00 res bath schedule 11 can't inspect schedule.
res bath dist|Building Unit 101=0.0 Service Hot Water Loop res bath dist|Building Unit 101=0.0 1_Bdrm_1_2 0.00 res bath schedule 12 can't inspect schedule.
res bath dist|Building Unit 102=0.0 Service Hot Water Loop res bath dist|Building Unit 102=0.0 1_Bdrm_2_2 0.00 res bath schedule 13 can't inspect schedule.
res bath dist|Building Unit 103=0.0 Service Hot Water Loop res bath dist|Building Unit 103=0.0 1_Bdrm_3_2 0.00 res bath schedule 14 can't inspect schedule.
res bath dist|Building Unit 104=0.0 Service Hot Water Loop res bath dist|Building Unit 104=0.0 1_Bdrm_4_2 0.00 res bath schedule 15 can't inspect schedule.
res bath dist|Building Unit 105=0.0 Service Hot Water Loop res bath dist|Building Unit 105=0.0 1_Bdrm_5_2 0.00 res bath schedule 16 can't inspect schedule.
res bath dist|Building Unit 106=0.0 Service Hot Water Loop res bath dist|Building Unit 106=0.0 1_Bdrm_6_2 0.00 res bath schedule 17 can't inspect schedule.
res bath dist|Building Unit 107=0.0 Service Hot Water Loop res bath dist|Building Unit 107=0.0 1_Bdrm_7_2 0.00 res bath schedule 18 can't inspect schedule.
res bath dist|Building Unit 108=0.0 Service Hot Water Loop res bath dist|Building Unit 108=0.0 1_Bdrm_1_3 0.00 res bath schedule 19 can't inspect schedule.
res bath dist|Building Unit 109=0.0 Service Hot Water Loop res bath dist|Building Unit 109=0.0 1_Bdrm_2_3 0.00 res bath schedule 20 can't inspect schedule.
res bath dist|Building Unit 110=0.0 Service Hot Water Loop res bath dist|Building Unit 110=0.0 1_Bdrm_3_3 0.00 res bath schedule 21 can't inspect schedule.
res bath dist|Building Unit 111=0.0 Service Hot Water Loop res bath dist|Building Unit 111=0.0 1_Bdrm_4_3 0.00 res bath schedule 22 can't inspect schedule.
res bath dist|Building Unit 112=0.0 Service Hot Water Loop res bath dist|Building Unit 112=0.0 1_Bdrm_5_3 0.00 res bath schedule 23 can't inspect schedule.
res bath dist|Building Unit 113=0.0 Service Hot Water Loop res bath dist|Building Unit 113=0.0 1_Bdrm_6_3 0.00 res bath schedule 24 can't inspect schedule.
res bath dist|Building Unit 114=0.0 Service Hot Water Loop res bath dist|Building Unit 114=0.0 1_Bdrm_7_3 0.00 res bath schedule 25 can't inspect schedule.
res bath dist|Building Unit 115=0.0 Service Hot Water Loop res bath dist|Building Unit 115=0.0 1_Bdrm_1_4 0.00 res bath schedule 26 can't inspect schedule.
res bath dist|Building Unit 116=0.0 Service Hot Water Loop res bath dist|Building Unit 116=0.0 1_Bdrm_2_4 0.00 res bath schedule 27 can't inspect schedule.
res bath dist|Building Unit 117=0.0 Service Hot Water Loop res bath dist|Building Unit 117=0.0 1_Bdrm_3_4 0.00 res bath schedule 28 can't inspect schedule.
res bath dist|Building Unit 118=0.0 Service Hot Water Loop res bath dist|Building Unit 118=0.0 1_Bdrm_4_4 0.00 res bath schedule 29 can't inspect schedule.
res bath dist|Building Unit 119=0.0 Service Hot Water Loop res bath dist|Building Unit 119=0.0 1_Bdrm_5_4 0.00 res bath schedule 30 can't inspect schedule.
res bath dist|Building Unit 120=0.0 Service Hot Water Loop res bath dist|Building Unit 120=0.0 1_Bdrm_6_4 0.00 res bath schedule 31 can't inspect schedule.
res bath dist|Building Unit 121=0.0 Service Hot Water Loop res bath dist|Building Unit 121=0.0 1_Bdrm_7_4 0.00 res bath schedule 32 can't inspect schedule.
res bath dist|Building Unit 201=0.0 Service Hot Water Loop res bath dist|Building Unit 201=0.0 2_Bdrm_1_2 0.00 res bath schedule 33 can't inspect schedule.
res bath dist|Building Unit 202=0.0 Service Hot Water Loop res bath dist|Building Unit 202=0.0 2_Bdrm_2_2 0.00 res bath schedule 34 can't inspect schedule.
res bath dist|Building Unit 203=0.0 Service Hot Water Loop res bath dist|Building Unit 203=0.0 2_Bdrm_3_2 0.00 res bath schedule 35 can't inspect schedule.
res bath dist|Building Unit 204=0.0 Service Hot Water Loop res bath dist|Building Unit 204=0.0 2_Bdrm_1_3 0.00 res bath schedule 36 can't inspect schedule.
res bath dist|Building Unit 205=0.0 Service Hot Water Loop res bath dist|Building Unit 205=0.0 2_Bdrm_2_3 0.00 res bath schedule 37 can't inspect schedule.
res bath dist|Building Unit 206=0.0 Service Hot Water Loop res bath dist|Building Unit 206=0.0 2_Bdrm_3_3 0.00 res bath schedule 38 can't inspect schedule.
res bath dist|Building Unit 207=0.0 Service Hot Water Loop res bath dist|Building Unit 207=0.0 2_Bdrm_1_4 0.00 res bath schedule 39 can't inspect schedule.
res bath dist|Building Unit 208=0.0 Service Hot Water Loop res bath dist|Building Unit 208=0.0 2_Bdrm_2_4 0.00 res bath schedule 40 can't inspect schedule.
res bath dist|Building Unit 209=0.0 Service Hot Water Loop res bath dist|Building Unit 209=0.0 2_Bdrm_3_4 0.00 res bath schedule 41 can't inspect schedule.
res bath dist|Building Unit 301=0.0 Service Hot Water Loop res bath dist|Building Unit 301=0.0 3_Bdrm_2_2 0.00 res bath schedule 42 can't inspect schedule.
res bath dist|Building Unit 302=0.0 Service Hot Water Loop res bath dist|Building Unit 302=0.0 3_Bdrm_1_3 0.00 res bath schedule 43 can't inspect schedule.
res bath dist|Building Unit 303=0.0 Service Hot Water Loop res bath dist|Building Unit 303=0.0 3_Bdrm_1_4 0.00 res bath schedule 44 can't inspect schedule.
res bath|Building Unit 001 Service Hot Water Loop res bath|Building Unit 001 0_Bdrm_1_2 5.59 res bath schedule can't inspect schedule.
res bath|Building Unit 002 Service Hot Water Loop res bath|Building Unit 002 0_Bdrm_2_2 5.59 res bath schedule 1 can't inspect schedule.
res bath|Building Unit 003 Service Hot Water Loop res bath|Building Unit 003 0_Bdrm_3_2 5.59 res bath schedule 2 can't inspect schedule.
res bath|Building Unit 004 Service Hot Water Loop res bath|Building Unit 004 0_Bdrm_4_2 5.59 res bath schedule 3 can't inspect schedule.
res bath|Building Unit 005 Service Hot Water Loop res bath|Building Unit 005 0_Bdrm_1_3 5.59 res bath schedule 4 can't inspect schedule.
res bath|Building Unit 006 Service Hot Water Loop res bath|Building Unit 006 0_Bdrm_2_3 5.59 res bath schedule 5 can't inspect schedule.
res bath|Building Unit 007 Service Hot Water Loop res bath|Building Unit 007 0_Bdrm_3_3 5.59 res bath schedule 6 can't inspect schedule.
res bath|Building Unit 008 Service Hot Water Loop res bath|Building Unit 008 0_Bdrm_4_3 5.59 res bath schedule 7 can't inspect schedule.
res bath|Building Unit 009 Service Hot Water Loop res bath|Building Unit 009 0_Bdrm_1_4 5.59 res bath schedule 8 can't inspect schedule.
res bath|Building Unit 010 Service Hot Water Loop res bath|Building Unit 010 0_Bdrm_2_4 5.59 res bath schedule 9 can't inspect schedule.
res bath|Building Unit 011 Service Hot Water Loop res bath|Building Unit 011 0_Bdrm_3_4 5.59 res bath schedule 10 can't inspect schedule.
res bath|Building Unit 012 Service Hot Water Loop res bath|Building Unit 012 0_Bdrm_4_4 5.59 res bath schedule 11 can't inspect schedule.
res bath|Building Unit 101 Service Hot Water Loop res bath|Building Unit 101 1_Bdrm_1_2 7.45 res bath schedule 12 can't inspect schedule.
res bath|Building Unit 102 Service Hot Water Loop res bath|Building Unit 102 1_Bdrm_2_2 7.45 res bath schedule 13 can't inspect schedule.
res bath|Building Unit 103 Service Hot Water Loop res bath|Building Unit 103 1_Bdrm_3_2 7.45 res bath schedule 14 can't inspect schedule.
res bath|Building Unit 104 Service Hot Water Loop res bath|Building Unit 104 1_Bdrm_4_2 7.45 res bath schedule 15 can't inspect schedule.
res bath|Building Unit 105 Service Hot Water Loop res bath|Building Unit 105 1_Bdrm_5_2 7.45 res bath schedule 16 can't inspect schedule.
res bath|Building Unit 106 Service Hot Water Loop res bath|Building Unit 106 1_Bdrm_6_2 7.45 res bath schedule 17 can't inspect schedule.
res bath|Building Unit 107 Service Hot Water Loop res bath|Building Unit 107 1_Bdrm_7_2 7.45 res bath schedule 18 can't inspect schedule.
res bath|Building Unit 108 Service Hot Water Loop res bath|Building Unit 108 1_Bdrm_1_3 7.45 res bath schedule 19 can't inspect schedule.
res bath|Building Unit 109 Service Hot Water Loop res bath|Building Unit 109 1_Bdrm_2_3 7.45 res bath schedule 20 can't inspect schedule.
res bath|Building Unit 110 Service Hot Water Loop res bath|Building Unit 110 1_Bdrm_3_3 7.45 res bath schedule 21 can't inspect schedule.
res bath|Building Unit 111 Service Hot Water Loop res bath|Building Unit 111 1_Bdrm_4_3 7.45 res bath schedule 22 can't inspect schedule.
res bath|Building Unit 112 Service Hot Water Loop res bath|Building Unit 112 1_Bdrm_5_3 7.45 res bath schedule 23 can't inspect schedule.
res bath|Building Unit 113 Service Hot Water Loop res bath|Building Unit 113 1_Bdrm_6_3 7.45 res bath schedule 24 can't inspect schedule.
res bath|Building Unit 114 Service Hot Water Loop res bath|Building Unit 114 1_Bdrm_7_3 7.45 res bath schedule 25 can't inspect schedule.
res bath|Building Unit 115 Service Hot Water Loop res bath|Building Unit 115 1_Bdrm_1_4 7.45 res bath schedule 26 can't inspect schedule.
res bath|Building Unit 116 Service Hot Water Loop res bath|Building Unit 116 1_Bdrm_2_4 7.45 res bath schedule 27 can't inspect schedule.
res bath|Building Unit 117 Service Hot Water Loop res bath|Building Unit 117 1_Bdrm_3_4 7.45 res bath schedule 28 can't inspect schedule.
res bath|Building Unit 118 Service Hot Water Loop res bath|Building Unit 118 1_Bdrm_4_4 7.45 res bath schedule 29 can't inspect schedule.
res bath|Building Unit 119 Service Hot Water Loop res bath|Building Unit 119 1_Bdrm_5_4 7.45 res bath schedule 30 can't inspect schedule.
res bath|Building Unit 120 Service Hot Water Loop res bath|Building Unit 120 1_Bdrm_6_4 7.45 res bath schedule 31 can't inspect schedule.
res bath|Building Unit 121 Service Hot Water Loop res bath|Building Unit 121 1_Bdrm_7_4 7.45 res bath schedule 32 can't inspect schedule.
res bath|Building Unit 201 Service Hot Water Loop res bath|Building Unit 201 2_Bdrm_1_2 6.52 res bath schedule 33 can't inspect schedule.
res bath|Building Unit 202 Service Hot Water Loop res bath|Building Unit 202 2_Bdrm_2_2 6.52 res bath schedule 34 can't inspect schedule.
res bath|Building Unit 203 Service Hot Water Loop res bath|Building Unit 203 2_Bdrm_3_2 6.52 res bath schedule 35 can't inspect schedule.
res bath|Building Unit 204 Service Hot Water Loop res bath|Building Unit 204 2_Bdrm_1_3 6.52 res bath schedule 36 can't inspect schedule.
res bath|Building Unit 205 Service Hot Water Loop res bath|Building Unit 205 2_Bdrm_2_3 6.52 res bath schedule 37 can't inspect schedule.
res bath|Building Unit 206 Service Hot Water Loop res bath|Building Unit 206 2_Bdrm_3_3 6.52 res bath schedule 38 can't inspect schedule.
res bath|Building Unit 207 Service Hot Water Loop res bath|Building Unit 207 2_Bdrm_1_4 6.52 res bath schedule 39 can't inspect schedule.
res bath|Building Unit 208 Service Hot Water Loop res bath|Building Unit 208 2_Bdrm_2_4 6.52 res bath schedule 40 can't inspect schedule.
res bath|Building Unit 209 Service Hot Water Loop res bath|Building Unit 209 2_Bdrm_3_4 6.52 res bath schedule 41 can't inspect schedule.
res bath|Building Unit 301 Service Hot Water Loop res bath|Building Unit 301 3_Bdrm_2_2 6.81 res bath schedule 42 can't inspect schedule.
res bath|Building Unit 302 Service Hot Water Loop res bath|Building Unit 302 3_Bdrm_1_3 6.81 res bath schedule 43 can't inspect schedule.
res bath|Building Unit 303 Service Hot Water Loop res bath|Building Unit 303 3_Bdrm_1_4 6.81 res bath schedule 44 can't inspect schedule.
res cw|Building Unit 001 Service Hot Water Loop res cw|Building Unit 001 0_Bdrm_1_2 0.48 res cw schedule can't inspect schedule.
res cw|Building Unit 002 Service Hot Water Loop res cw|Building Unit 002 0_Bdrm_2_2 0.48 res cw schedule 1 can't inspect schedule.
res cw|Building Unit 003 Service Hot Water Loop res cw|Building Unit 003 0_Bdrm_3_2 0.48 res cw schedule 2 can't inspect schedule.
res cw|Building Unit 004 Service Hot Water Loop res cw|Building Unit 004 0_Bdrm_4_2 0.48 res cw schedule 3 can't inspect schedule.
res cw|Building Unit 005 Service Hot Water Loop res cw|Building Unit 005 0_Bdrm_1_3 0.48 res cw schedule 4 can't inspect schedule.
res cw|Building Unit 006 Service Hot Water Loop res cw|Building Unit 006 0_Bdrm_2_3 0.48 res cw schedule 5 can't inspect schedule.
res cw|Building Unit 007 Service Hot Water Loop res cw|Building Unit 007 0_Bdrm_3_3 0.48 res cw schedule 6 can't inspect schedule.
res cw|Building Unit 008 Service Hot Water Loop res cw|Building Unit 008 0_Bdrm_4_3 0.48 res cw schedule 7 can't inspect schedule.
res cw|Building Unit 009 Service Hot Water Loop res cw|Building Unit 009 0_Bdrm_1_4 0.48 res cw schedule 8 can't inspect schedule.
res cw|Building Unit 010 Service Hot Water Loop res cw|Building Unit 010 0_Bdrm_2_4 0.48 res cw schedule 9 can't inspect schedule.
res cw|Building Unit 011 Service Hot Water Loop res cw|Building Unit 011 0_Bdrm_3_4 0.48 res cw schedule 10 can't inspect schedule.
res cw|Building Unit 012 Service Hot Water Loop res cw|Building Unit 012 0_Bdrm_4_4 0.48 res cw schedule 11 can't inspect schedule.
res cw|Building Unit 101 Service Hot Water Loop res cw|Building Unit 101 1_Bdrm_1_2 0.64 res cw schedule 12 can't inspect schedule.
res cw|Building Unit 102 Service Hot Water Loop res cw|Building Unit 102 1_Bdrm_2_2 0.64 res cw schedule 13 can't inspect schedule.
res cw|Building Unit 103 Service Hot Water Loop res cw|Building Unit 103 1_Bdrm_3_2 0.64 res cw schedule 14 can't inspect schedule.
res cw|Building Unit 104 Service Hot Water Loop res cw|Building Unit 104 1_Bdrm_4_2 0.64 res cw schedule 15 can't inspect schedule.
res cw|Building Unit 105 Service Hot Water Loop res cw|Building Unit 105 1_Bdrm_5_2 0.64 res cw schedule 16 can't inspect schedule.
res cw|Building Unit 106 Service Hot Water Loop res cw|Building Unit 106 1_Bdrm_6_2 0.64 res cw schedule 17 can't inspect schedule.
res cw|Building Unit 107 Service Hot Water Loop res cw|Building Unit 107 1_Bdrm_7_2 0.64 res cw schedule 18 can't inspect schedule.
res cw|Building Unit 108 Service Hot Water Loop res cw|Building Unit 108 1_Bdrm_1_3 0.64 res cw schedule 19 can't inspect schedule.
res cw|Building Unit 109 Service Hot Water Loop res cw|Building Unit 109 1_Bdrm_2_3 0.64 res cw schedule 20 can't inspect schedule.
res cw|Building Unit 110 Service Hot Water Loop res cw|Building Unit 110 1_Bdrm_3_3 0.64 res cw schedule 21 can't inspect schedule.
res cw|Building Unit 111 Service Hot Water Loop res cw|Building Unit 111 1_Bdrm_4_3 0.64 res cw schedule 22 can't inspect schedule.
res cw|Building Unit 112 Service Hot Water Loop res cw|Building Unit 112 1_Bdrm_5_3 0.64 res cw schedule 23 can't inspect schedule.
res cw|Building Unit 113 Service Hot Water Loop res cw|Building Unit 113 1_Bdrm_6_3 0.64 res cw schedule 24 can't inspect schedule.
res cw|Building Unit 114 Service Hot Water Loop res cw|Building Unit 114 1_Bdrm_7_3 0.64 res cw schedule 25 can't inspect schedule.
res cw|Building Unit 115 Service Hot Water Loop res cw|Building Unit 115 1_Bdrm_1_4 0.64 res cw schedule 26 can't inspect schedule.
res cw|Building Unit 116 Service Hot Water Loop res cw|Building Unit 116 1_Bdrm_2_4 0.64 res cw schedule 27 can't inspect schedule.
res cw|Building Unit 117 Service Hot Water Loop res cw|Building Unit 117 1_Bdrm_3_4 0.64 res cw schedule 28 can't inspect schedule.
res cw|Building Unit 118 Service Hot Water Loop res cw|Building Unit 118 1_Bdrm_4_4 0.64 res cw schedule 29 can't inspect schedule.
res cw|Building Unit 119 Service Hot Water Loop res cw|Building Unit 119 1_Bdrm_5_4 0.64 res cw schedule 30 can't inspect schedule.
res cw|Building Unit 120 Service Hot Water Loop res cw|Building Unit 120 1_Bdrm_6_4 0.64 res cw schedule 31 can't inspect schedule.
res cw|Building Unit 121 Service Hot Water Loop res cw|Building Unit 121 1_Bdrm_7_4 0.64 res cw schedule 32 can't inspect schedule.
res cw|Building Unit 201 Service Hot Water Loop res cw|Building Unit 201 2_Bdrm_1_2 0.70 res cw schedule 33 can't inspect schedule.
res cw|Building Unit 202 Service Hot Water Loop res cw|Building Unit 202 2_Bdrm_2_2 0.70 res cw schedule 34 can't inspect schedule.
res cw|Building Unit 203 Service Hot Water Loop res cw|Building Unit 203 2_Bdrm_3_2 0.70 res cw schedule 35 can't inspect schedule.
res cw|Building Unit 204 Service Hot Water Loop res cw|Building Unit 204 2_Bdrm_1_3 0.70 res cw schedule 36 can't inspect schedule.
res cw|Building Unit 205 Service Hot Water Loop res cw|Building Unit 205 2_Bdrm_2_3 0.70 res cw schedule 37 can't inspect schedule.
res cw|Building Unit 206 Service Hot Water Loop res cw|Building Unit 206 2_Bdrm_3_3 0.70 res cw schedule 38 can't inspect schedule.
res cw|Building Unit 207 Service Hot Water Loop res cw|Building Unit 207 2_Bdrm_1_4 0.70 res cw schedule 39 can't inspect schedule.
res cw|Building Unit 208 Service Hot Water Loop res cw|Building Unit 208 2_Bdrm_2_4 0.70 res cw schedule 40 can't inspect schedule.
res cw|Building Unit 209 Service Hot Water Loop res cw|Building Unit 209 2_Bdrm_3_4 0.70 res cw schedule 41 can't inspect schedule.
res cw|Building Unit 301 Service Hot Water Loop res cw|Building Unit 301 3_Bdrm_2_2 0.74 res cw schedule 42 can't inspect schedule.
res cw|Building Unit 302 Service Hot Water Loop res cw|Building Unit 302 3_Bdrm_1_3 0.74 res cw schedule 43 can't inspect schedule.
res cw|Building Unit 303 Service Hot Water Loop res cw|Building Unit 303 3_Bdrm_1_4 0.74 res cw schedule 44 can't inspect schedule.
res dw|Building Unit 001 Service Hot Water Loop res dw|Building Unit 001 0_Bdrm_1_2 0.45 res dw schedule can't inspect schedule.
res dw|Building Unit 002 Service Hot Water Loop res dw|Building Unit 002 0_Bdrm_2_2 0.45 res dw schedule 1 can't inspect schedule.
res dw|Building Unit 003 Service Hot Water Loop res dw|Building Unit 003 0_Bdrm_3_2 0.45 res dw schedule 2 can't inspect schedule.
res dw|Building Unit 004 Service Hot Water Loop res dw|Building Unit 004 0_Bdrm_4_2 0.45 res dw schedule 3 can't inspect schedule.
res dw|Building Unit 005 Service Hot Water Loop res dw|Building Unit 005 0_Bdrm_1_3 0.45 res dw schedule 4 can't inspect schedule.
res dw|Building Unit 006 Service Hot Water Loop res dw|Building Unit 006 0_Bdrm_2_3 0.45 res dw schedule 5 can't inspect schedule.
res dw|Building Unit 007 Service Hot Water Loop res dw|Building Unit 007 0_Bdrm_3_3 0.45 res dw schedule 6 can't inspect schedule.
res dw|Building Unit 008 Service Hot Water Loop res dw|Building Unit 008 0_Bdrm_4_3 0.45 res dw schedule 7 can't inspect schedule.
res dw|Building Unit 009 Service Hot Water Loop res dw|Building Unit 009 0_Bdrm_1_4 0.45 res dw schedule 8 can't inspect schedule.
res dw|Building Unit 010 Service Hot Water Loop res dw|Building Unit 010 0_Bdrm_2_4 0.45 res dw schedule 9 can't inspect schedule.
res dw|Building Unit 011 Service Hot Water Loop res dw|Building Unit 011 0_Bdrm_3_4 0.45 res dw schedule 10 can't inspect schedule.
res dw|Building Unit 012 Service Hot Water Loop res dw|Building Unit 012 0_Bdrm_4_4 0.45 res dw schedule 11 can't inspect schedule.
res dw|Building Unit 101 Service Hot Water Loop res dw|Building Unit 101 1_Bdrm_1_2 0.60 res dw schedule 12 can't inspect schedule.
res dw|Building Unit 102 Service Hot Water Loop res dw|Building Unit 102 1_Bdrm_2_2 0.60 res dw schedule 13 can't inspect schedule.
res dw|Building Unit 103 Service Hot Water Loop res dw|Building Unit 103 1_Bdrm_3_2 0.60 res dw schedule 14 can't inspect schedule.
res dw|Building Unit 104 Service Hot Water Loop res dw|Building Unit 104 1_Bdrm_4_2 0.60 res dw schedule 15 can't inspect schedule.
res dw|Building Unit 105 Service Hot Water Loop res dw|Building Unit 105 1_Bdrm_5_2 0.60 res dw schedule 16 can't inspect schedule.
res dw|Building Unit 106 Service Hot Water Loop res dw|Building Unit 106 1_Bdrm_6_2 0.60 res dw schedule 17 can't inspect schedule.
res dw|Building Unit 107 Service Hot Water Loop res dw|Building Unit 107 1_Bdrm_7_2 0.60 res dw schedule 18 can't inspect schedule.
res dw|Building Unit 108 Service Hot Water Loop res dw|Building Unit 108 1_Bdrm_1_3 0.60 res dw schedule 19 can't inspect schedule.
res dw|Building Unit 109 Service Hot Water Loop res dw|Building Unit 109 1_Bdrm_2_3 0.60 res dw schedule 20 can't inspect schedule.
res dw|Building Unit 110 Service Hot Water Loop res dw|Building Unit 110 1_Bdrm_3_3 0.60 res dw schedule 21 can't inspect schedule.
res dw|Building Unit 111 Service Hot Water Loop res dw|Building Unit 111 1_Bdrm_4_3 0.60 res dw schedule 22 can't inspect schedule.
res dw|Building Unit 112 Service Hot Water Loop res dw|Building Unit 112 1_Bdrm_5_3 0.60 res dw schedule 23 can't inspect schedule.
res dw|Building Unit 113 Service Hot Water Loop res dw|Building Unit 113 1_Bdrm_6_3 0.60 res dw schedule 24 can't inspect schedule.
res dw|Building Unit 114 Service Hot Water Loop res dw|Building Unit 114 1_Bdrm_7_3 0.60 res dw schedule 25 can't inspect schedule.
res dw|Building Unit 115 Service Hot Water Loop res dw|Building Unit 115 1_Bdrm_1_4 0.60 res dw schedule 26 can't inspect schedule.
res dw|Building Unit 116 Service Hot Water Loop res dw|Building Unit 116 1_Bdrm_2_4 0.60 res dw schedule 27 can't inspect schedule.
res dw|Building Unit 117 Service Hot Water Loop res dw|Building Unit 117 1_Bdrm_3_4 0.60 res dw schedule 28 can't inspect schedule.
res dw|Building Unit 118 Service Hot Water Loop res dw|Building Unit 118 1_Bdrm_4_4 0.60 res dw schedule 29 can't inspect schedule.
res dw|Building Unit 119 Service Hot Water Loop res dw|Building Unit 119 1_Bdrm_5_4 0.60 res dw schedule 30 can't inspect schedule.
res dw|Building Unit 120 Service Hot Water Loop res dw|Building Unit 120 1_Bdrm_6_4 0.60 res dw schedule 31 can't inspect schedule.
res dw|Building Unit 121 Service Hot Water Loop res dw|Building Unit 121 1_Bdrm_7_4 0.60 res dw schedule 32 can't inspect schedule.
res dw|Building Unit 201 Service Hot Water Loop res dw|Building Unit 201 2_Bdrm_1_2 0.58 res dw schedule 33 can't inspect schedule.
res dw|Building Unit 202 Service Hot Water Loop res dw|Building Unit 202 2_Bdrm_2_2 0.58 res dw schedule 34 can't inspect schedule.
res dw|Building Unit 203 Service Hot Water Loop res dw|Building Unit 203 2_Bdrm_3_2 0.58 res dw schedule 35 can't inspect schedule.
res dw|Building Unit 204 Service Hot Water Loop res dw|Building Unit 204 2_Bdrm_1_3 0.58 res dw schedule 36 can't inspect schedule.
res dw|Building Unit 205 Service Hot Water Loop res dw|Building Unit 205 2_Bdrm_2_3 0.58 res dw schedule 37 can't inspect schedule.
res dw|Building Unit 206 Service Hot Water Loop res dw|Building Unit 206 2_Bdrm_3_3 0.58 res dw schedule 38 can't inspect schedule.
res dw|Building Unit 207 Service Hot Water Loop res dw|Building Unit 207 2_Bdrm_1_4 0.58 res dw schedule 39 can't inspect schedule.
res dw|Building Unit 208 Service Hot Water Loop res dw|Building Unit 208 2_Bdrm_2_4 0.58 res dw schedule 40 can't inspect schedule.
res dw|Building Unit 209 Service Hot Water Loop res dw|Building Unit 209 2_Bdrm_3_4 0.58 res dw schedule 41 can't inspect schedule.
res dw|Building Unit 301 Service Hot Water Loop res dw|Building Unit 301 3_Bdrm_2_2 0.61 res dw schedule 42 can't inspect schedule.
res dw|Building Unit 302 Service Hot Water Loop res dw|Building Unit 302 3_Bdrm_1_3 0.61 res dw schedule 43 can't inspect schedule.
res dw|Building Unit 303 Service Hot Water Loop res dw|Building Unit 303 3_Bdrm_1_4 0.61 res dw schedule 44 can't inspect schedule.
res shower dist|Building Unit 001=0.0 Service Hot Water Loop res shower dist|Building Unit 001=0.0 0_Bdrm_1_2 0.00 res shower schedule can't inspect schedule.
res shower dist|Building Unit 002=0.0 Service Hot Water Loop res shower dist|Building Unit 002=0.0 0_Bdrm_2_2 0.00 res shower schedule 1 can't inspect schedule.
res shower dist|Building Unit 003=0.0 Service Hot Water Loop res shower dist|Building Unit 003=0.0 0_Bdrm_3_2 0.00 res shower schedule 2 can't inspect schedule.
res shower dist|Building Unit 004=0.0 Service Hot Water Loop res shower dist|Building Unit 004=0.0 0_Bdrm_4_2 0.00 res shower schedule 3 can't inspect schedule.
res shower dist|Building Unit 005=0.0 Service Hot Water Loop res shower dist|Building Unit 005=0.0 0_Bdrm_1_3 0.00 res shower schedule 4 can't inspect schedule.
res shower dist|Building Unit 006=0.0 Service Hot Water Loop res shower dist|Building Unit 006=0.0 0_Bdrm_2_3 0.00 res shower schedule 5 can't inspect schedule.
res shower dist|Building Unit 007=0.0 Service Hot Water Loop res shower dist|Building Unit 007=0.0 0_Bdrm_3_3 0.00 res shower schedule 6 can't inspect schedule.
res shower dist|Building Unit 008=0.0 Service Hot Water Loop res shower dist|Building Unit 008=0.0 0_Bdrm_4_3 0.00 res shower schedule 7 can't inspect schedule.
res shower dist|Building Unit 009=0.0 Service Hot Water Loop res shower dist|Building Unit 009=0.0 0_Bdrm_1_4 0.00 res shower schedule 8 can't inspect schedule.
res shower dist|Building Unit 010=0.0 Service Hot Water Loop res shower dist|Building Unit 010=0.0 0_Bdrm_2_4 0.00 res shower schedule 9 can't inspect schedule.
res shower dist|Building Unit 011=0.0 Service Hot Water Loop res shower dist|Building Unit 011=0.0 0_Bdrm_3_4 0.00 res shower schedule 10 can't inspect schedule.
res shower dist|Building Unit 012=0.0 Service Hot Water Loop res shower dist|Building Unit 012=0.0 0_Bdrm_4_4 0.00 res shower schedule 11 can't inspect schedule.
res shower dist|Building Unit 101=0.0 Service Hot Water Loop res shower dist|Building Unit 101=0.0 1_Bdrm_1_2 0.00 res shower schedule 12 can't inspect schedule.
res shower dist|Building Unit 102=0.0 Service Hot Water Loop res shower dist|Building Unit 102=0.0 1_Bdrm_2_2 0.00 res shower schedule 13 can't inspect schedule.
res shower dist|Building Unit 103=0.0 Service Hot Water Loop res shower dist|Building Unit 103=0.0 1_Bdrm_3_2 0.00 res shower schedule 14 can't inspect schedule.
res shower dist|Building Unit 104=0.0 Service Hot Water Loop res shower dist|Building Unit 104=0.0 1_Bdrm_4_2 0.00 res shower schedule 15 can't inspect schedule.
res shower dist|Building Unit 105=0.0 Service Hot Water Loop res shower dist|Building Unit 105=0.0 1_Bdrm_5_2 0.00 res shower schedule 16 can't inspect schedule.
res shower dist|Building Unit 106=0.0 Service Hot Water Loop res shower dist|Building Unit 106=0.0 1_Bdrm_6_2 0.00 res shower schedule 17 can't inspect schedule.
res shower dist|Building Unit 107=0.0 Service Hot Water Loop res shower dist|Building Unit 107=0.0 1_Bdrm_7_2 0.00 res shower schedule 18 can't inspect schedule.
res shower dist|Building Unit 108=0.0 Service Hot Water Loop res shower dist|Building Unit 108=0.0 1_Bdrm_1_3 0.00 res shower schedule 19 can't inspect schedule.
res shower dist|Building Unit 109=0.0 Service Hot Water Loop res shower dist|Building Unit 109=0.0 1_Bdrm_2_3 0.00 res shower schedule 20 can't inspect schedule.
res shower dist|Building Unit 110=0.0 Service Hot Water Loop res shower dist|Building Unit 110=0.0 1_Bdrm_3_3 0.00 res shower schedule 21 can't inspect schedule.
res shower dist|Building Unit 111=0.0 Service Hot Water Loop res shower dist|Building Unit 111=0.0 1_Bdrm_4_3 0.00 res shower schedule 22 can't inspect schedule.
res shower dist|Building Unit 112=0.0 Service Hot Water Loop res shower dist|Building Unit 112=0.0 1_Bdrm_5_3 0.00 res shower schedule 23 can't inspect schedule.
res shower dist|Building Unit 113=0.0 Service Hot Water Loop res shower dist|Building Unit 113=0.0 1_Bdrm_6_3 0.00 res shower schedule 24 can't inspect schedule.
res shower dist|Building Unit 114=0.0 Service Hot Water Loop res shower dist|Building Unit 114=0.0 1_Bdrm_7_3 0.00 res shower schedule 25 can't inspect schedule.
res shower dist|Building Unit 115=0.0 Service Hot Water Loop res shower dist|Building Unit 115=0.0 1_Bdrm_1_4 0.00 res shower schedule 26 can't inspect schedule.
res shower dist|Building Unit 116=0.0 Service Hot Water Loop res shower dist|Building Unit 116=0.0 1_Bdrm_2_4 0.00 res shower schedule 27 can't inspect schedule.
res shower dist|Building Unit 117=0.0 Service Hot Water Loop res shower dist|Building Unit 117=0.0 1_Bdrm_3_4 0.00 res shower schedule 28 can't inspect schedule.
res shower dist|Building Unit 118=0.0 Service Hot Water Loop res shower dist|Building Unit 118=0.0 1_Bdrm_4_4 0.00 res shower schedule 29 can't inspect schedule.
res shower dist|Building Unit 119=0.0 Service Hot Water Loop res shower dist|Building Unit 119=0.0 1_Bdrm_5_4 0.00 res shower schedule 30 can't inspect schedule.
res shower dist|Building Unit 120=0.0 Service Hot Water Loop res shower dist|Building Unit 120=0.0 1_Bdrm_6_4 0.00 res shower schedule 31 can't inspect schedule.
res shower dist|Building Unit 121=0.0 Service Hot Water Loop res shower dist|Building Unit 121=0.0 1_Bdrm_7_4 0.00 res shower schedule 32 can't inspect schedule.
res shower dist|Building Unit 201=0.0 Service Hot Water Loop res shower dist|Building Unit 201=0.0 2_Bdrm_1_2 0.00 res shower schedule 33 can't inspect schedule.
res shower dist|Building Unit 202=0.0 Service Hot Water Loop res shower dist|Building Unit 202=0.0 2_Bdrm_2_2 0.00 res shower schedule 34 can't inspect schedule.
res shower dist|Building Unit 203=0.0 Service Hot Water Loop res shower dist|Building Unit 203=0.0 2_Bdrm_3_2 0.00 res shower schedule 35 can't inspect schedule.
res shower dist|Building Unit 204=0.0 Service Hot Water Loop res shower dist|Building Unit 204=0.0 2_Bdrm_1_3 0.00 res shower schedule 36 can't inspect schedule.
res shower dist|Building Unit 205=0.0 Service Hot Water Loop res shower dist|Building Unit 205=0.0 2_Bdrm_2_3 0.00 res shower schedule 37 can't inspect schedule.
res shower dist|Building Unit 206=0.0 Service Hot Water Loop res shower dist|Building Unit 206=0.0 2_Bdrm_3_3 0.00 res shower schedule 38 can't inspect schedule.
res shower dist|Building Unit 207=0.0 Service Hot Water Loop res shower dist|Building Unit 207=0.0 2_Bdrm_1_4 0.00 res shower schedule 39 can't inspect schedule.
res shower dist|Building Unit 208=0.0 Service Hot Water Loop res shower dist|Building Unit 208=0.0 2_Bdrm_2_4 0.00 res shower schedule 40 can't inspect schedule.
res shower dist|Building Unit 209=0.0 Service Hot Water Loop res shower dist|Building Unit 209=0.0 2_Bdrm_3_4 0.00 res shower schedule 41 can't inspect schedule.
res shower dist|Building Unit 301=0.0 Service Hot Water Loop res shower dist|Building Unit 301=0.0 3_Bdrm_2_2 0.00 res shower schedule 42 can't inspect schedule.
res shower dist|Building Unit 302=0.0 Service Hot Water Loop res shower dist|Building Unit 302=0.0 3_Bdrm_1_3 0.00 res shower schedule 43 can't inspect schedule.
res shower dist|Building Unit 303=0.0 Service Hot Water Loop res shower dist|Building Unit 303=0.0 3_Bdrm_1_4 0.00 res shower schedule 44 can't inspect schedule.
res shower|Building Unit 001 Service Hot Water Loop res shower|Building Unit 001 0_Bdrm_1_2 3.48 res shower schedule can't inspect schedule.
res shower|Building Unit 002 Service Hot Water Loop res shower|Building Unit 002 0_Bdrm_2_2 3.48 res shower schedule 1 can't inspect schedule.
res shower|Building Unit 003 Service Hot Water Loop res shower|Building Unit 003 0_Bdrm_3_2 3.48 res shower schedule 2 can't inspect schedule.
res shower|Building Unit 004 Service Hot Water Loop res shower|Building Unit 004 0_Bdrm_4_2 3.48 res shower schedule 3 can't inspect schedule.
res shower|Building Unit 005 Service Hot Water Loop res shower|Building Unit 005 0_Bdrm_1_3 3.48 res shower schedule 4 can't inspect schedule.
res shower|Building Unit 006 Service Hot Water Loop res shower|Building Unit 006 0_Bdrm_2_3 3.48 res shower schedule 5 can't inspect schedule.
res shower|Building Unit 007 Service Hot Water Loop res shower|Building Unit 007 0_Bdrm_3_3 3.48 res shower schedule 6 can't inspect schedule.
res shower|Building Unit 008 Service Hot Water Loop res shower|Building Unit 008 0_Bdrm_4_3 3.48 res shower schedule 7 can't inspect schedule.
res shower|Building Unit 009 Service Hot Water Loop res shower|Building Unit 009 0_Bdrm_1_4 3.48 res shower schedule 8 can't inspect schedule.
res shower|Building Unit 010 Service Hot Water Loop res shower|Building Unit 010 0_Bdrm_2_4 3.48 res shower schedule 9 can't inspect schedule.
res shower|Building Unit 011 Service Hot Water Loop res shower|Building Unit 011 0_Bdrm_3_4 3.48 res shower schedule 10 can't inspect schedule.
res shower|Building Unit 012 Service Hot Water Loop res shower|Building Unit 012 0_Bdrm_4_4 3.48 res shower schedule 11 can't inspect schedule.
res shower|Building Unit 101 Service Hot Water Loop res shower|Building Unit 101 1_Bdrm_1_2 4.64 res shower schedule 12 can't inspect schedule.
res shower|Building Unit 102 Service Hot Water Loop res shower|Building Unit 102 1_Bdrm_2_2 4.64 res shower schedule 13 can't inspect schedule.
res shower|Building Unit 103 Service Hot Water Loop res shower|Building Unit 103 1_Bdrm_3_2 4.64 res shower schedule 14 can't inspect schedule.
res shower|Building Unit 104 Service Hot Water Loop res shower|Building Unit 104 1_Bdrm_4_2 4.64 res shower schedule 15 can't inspect schedule.
res shower|Building Unit 105 Service Hot Water Loop res shower|Building Unit 105 1_Bdrm_5_2 4.64 res shower schedule 16 can't inspect schedule.
res shower|Building Unit 106 Service Hot Water Loop res shower|Building Unit 106 1_Bdrm_6_2 4.64 res shower schedule 17 can't inspect schedule.
res shower|Building Unit 107 Service Hot Water Loop res shower|Building Unit 107 1_Bdrm_7_2 4.64 res shower schedule 18 can't inspect schedule.
res shower|Building Unit 108 Service Hot Water Loop res shower|Building Unit 108 1_Bdrm_1_3 4.64 res shower schedule 19 can't inspect schedule.
res shower|Building Unit 109 Service Hot Water Loop res shower|Building Unit 109 1_Bdrm_2_3 4.64 res shower schedule 20 can't inspect schedule.
res shower|Building Unit 110 Service Hot Water Loop res shower|Building Unit 110 1_Bdrm_3_3 4.64 res shower schedule 21 can't inspect schedule.
res shower|Building Unit 111 Service Hot Water Loop res shower|Building Unit 111 1_Bdrm_4_3 4.64 res shower schedule 22 can't inspect schedule.
res shower|Building Unit 112 Service Hot Water Loop res shower|Building Unit 112 1_Bdrm_5_3 4.64 res shower schedule 23 can't inspect schedule.
res shower|Building Unit 113 Service Hot Water Loop res shower|Building Unit 113 1_Bdrm_6_3 4.64 res shower schedule 24 can't inspect schedule.
res shower|Building Unit 114 Service Hot Water Loop res shower|Building Unit 114 1_Bdrm_7_3 4.64 res shower schedule 25 can't inspect schedule.
res shower|Building Unit 115 Service Hot Water Loop res shower|Building Unit 115 1_Bdrm_1_4 4.64 res shower schedule 26 can't inspect schedule.
res shower|Building Unit 116 Service Hot Water Loop res shower|Building Unit 116 1_Bdrm_2_4 4.64 res shower schedule 27 can't inspect schedule.
res shower|Building Unit 117 Service Hot Water Loop res shower|Building Unit 117 1_Bdrm_3_4 4.64 res shower schedule 28 can't inspect schedule.
res shower|Building Unit 118 Service Hot Water Loop res shower|Building Unit 118 1_Bdrm_4_4 4.64 res shower schedule 29 can't inspect schedule.
res shower|Building Unit 119 Service Hot Water Loop res shower|Building Unit 119 1_Bdrm_5_4 4.64 res shower schedule 30 can't inspect schedule.
res shower|Building Unit 120 Service Hot Water Loop res shower|Building Unit 120 1_Bdrm_6_4 4.64 res shower schedule 31 can't inspect schedule.
res shower|Building Unit 121 Service Hot Water Loop res shower|Building Unit 121 1_Bdrm_7_4 4.64 res shower schedule 32 can't inspect schedule.
res shower|Building Unit 201 Service Hot Water Loop res shower|Building Unit 201 2_Bdrm_1_2 4.69 res shower schedule 33 can't inspect schedule.
res shower|Building Unit 202 Service Hot Water Loop res shower|Building Unit 202 2_Bdrm_2_2 4.69 res shower schedule 34 can't inspect schedule.
res shower|Building Unit 203 Service Hot Water Loop res shower|Building Unit 203 2_Bdrm_3_2 4.69 res shower schedule 35 can't inspect schedule.
res shower|Building Unit 204 Service Hot Water Loop res shower|Building Unit 204 2_Bdrm_1_3 4.69 res shower schedule 36 can't inspect schedule.
res shower|Building Unit 205 Service Hot Water Loop res shower|Building Unit 205 2_Bdrm_2_3 4.69 res shower schedule 37 can't inspect schedule.
res shower|Building Unit 206 Service Hot Water Loop res shower|Building Unit 206 2_Bdrm_3_3 4.69 res shower schedule 38 can't inspect schedule.
res shower|Building Unit 207 Service Hot Water Loop res shower|Building Unit 207 2_Bdrm_1_4 4.69 res shower schedule 39 can't inspect schedule.
res shower|Building Unit 208 Service Hot Water Loop res shower|Building Unit 208 2_Bdrm_2_4 4.69 res shower schedule 40 can't inspect schedule.
res shower|Building Unit 209 Service Hot Water Loop res shower|Building Unit 209 2_Bdrm_3_4 4.69 res shower schedule 41 can't inspect schedule.
res shower|Building Unit 301 Service Hot Water Loop res shower|Building Unit 301 3_Bdrm_2_2 4.35 res shower schedule 42 can't inspect schedule.
res shower|Building Unit 302 Service Hot Water Loop res shower|Building Unit 302 3_Bdrm_1_3 4.35 res shower schedule 43 can't inspect schedule.
res shower|Building Unit 303 Service Hot Water Loop res shower|Building Unit 303 3_Bdrm_1_4 4.35 res shower schedule 44 can't inspect schedule.
res sink dist|Building Unit 001=0.0 Service Hot Water Loop res sink dist|Building Unit 001=0.0 0_Bdrm_1_2 0.00 res sink schedule can't inspect schedule.
res sink dist|Building Unit 002=0.0 Service Hot Water Loop res sink dist|Building Unit 002=0.0 0_Bdrm_2_2 0.00 res sink schedule 1 can't inspect schedule.
res sink dist|Building Unit 003=0.0 Service Hot Water Loop res sink dist|Building Unit 003=0.0 0_Bdrm_3_2 0.00 res sink schedule 2 can't inspect schedule.
res sink dist|Building Unit 004=0.0 Service Hot Water Loop res sink dist|Building Unit 004=0.0 0_Bdrm_4_2 0.00 res sink schedule 3 can't inspect schedule.
res sink dist|Building Unit 005=0.0 Service Hot Water Loop res sink dist|Building Unit 005=0.0 0_Bdrm_1_3 0.00 res sink schedule 4 can't inspect schedule.
res sink dist|Building Unit 006=0.0 Service Hot Water Loop res sink dist|Building Unit 006=0.0 0_Bdrm_2_3 0.00 res sink schedule 5 can't inspect schedule.
res sink dist|Building Unit 007=0.0 Service Hot Water Loop res sink dist|Building Unit 007=0.0 0_Bdrm_3_3 0.00 res sink schedule 6 can't inspect schedule.
res sink dist|Building Unit 008=0.0 Service Hot Water Loop res sink dist|Building Unit 008=0.0 0_Bdrm_4_3 0.00 res sink schedule 7 can't inspect schedule.
res sink dist|Building Unit 009=0.0 Service Hot Water Loop res sink dist|Building Unit 009=0.0 0_Bdrm_1_4 0.00 res sink schedule 8 can't inspect schedule.
res sink dist|Building Unit 010=0.0 Service Hot Water Loop res sink dist|Building Unit 010=0.0 0_Bdrm_2_4 0.00 res sink schedule 9 can't inspect schedule.
res sink dist|Building Unit 011=0.0 Service Hot Water Loop res sink dist|Building Unit 011=0.0 0_Bdrm_3_4 0.00 res sink schedule 10 can't inspect schedule.
res sink dist|Building Unit 012=0.0 Service Hot Water Loop res sink dist|Building Unit 012=0.0 0_Bdrm_4_4 0.00 res sink schedule 11 can't inspect schedule.
res sink dist|Building Unit 101=0.0 Service Hot Water Loop res sink dist|Building Unit 101=0.0 1_Bdrm_1_2 0.00 res sink schedule 12 can't inspect schedule.
res sink dist|Building Unit 102=0.0 Service Hot Water Loop res sink dist|Building Unit 102=0.0 1_Bdrm_2_2 0.00 res sink schedule 13 can't inspect schedule.
res sink dist|Building Unit 103=0.0 Service Hot Water Loop res sink dist|Building Unit 103=0.0 1_Bdrm_3_2 0.00 res sink schedule 14 can't inspect schedule.
res sink dist|Building Unit 104=0.0 Service Hot Water Loop res sink dist|Building Unit 104=0.0 1_Bdrm_4_2 0.00 res sink schedule 15 can't inspect schedule.
res sink dist|Building Unit 105=0.0 Service Hot Water Loop res sink dist|Building Unit 105=0.0 1_Bdrm_5_2 0.00 res sink schedule 16 can't inspect schedule.
res sink dist|Building Unit 106=0.0 Service Hot Water Loop res sink dist|Building Unit 106=0.0 1_Bdrm_6_2 0.00 res sink schedule 17 can't inspect schedule.
res sink dist|Building Unit 107=0.0 Service Hot Water Loop res sink dist|Building Unit 107=0.0 1_Bdrm_7_2 0.00 res sink schedule 18 can't inspect schedule.
res sink dist|Building Unit 108=0.0 Service Hot Water Loop res sink dist|Building Unit 108=0.0 1_Bdrm_1_3 0.00 res sink schedule 19 can't inspect schedule.
res sink dist|Building Unit 109=0.0 Service Hot Water Loop res sink dist|Building Unit 109=0.0 1_Bdrm_2_3 0.00 res sink schedule 20 can't inspect schedule.
res sink dist|Building Unit 110=0.0 Service Hot Water Loop res sink dist|Building Unit 110=0.0 1_Bdrm_3_3 0.00 res sink schedule 21 can't inspect schedule.
res sink dist|Building Unit 111=0.0 Service Hot Water Loop res sink dist|Building Unit 111=0.0 1_Bdrm_4_3 0.00 res sink schedule 22 can't inspect schedule.
res sink dist|Building Unit 112=0.0 Service Hot Water Loop res sink dist|Building Unit 112=0.0 1_Bdrm_5_3 0.00 res sink schedule 23 can't inspect schedule.
res sink dist|Building Unit 113=0.0 Service Hot Water Loop res sink dist|Building Unit 113=0.0 1_Bdrm_6_3 0.00 res sink schedule 24 can't inspect schedule.
res sink dist|Building Unit 114=0.0 Service Hot Water Loop res sink dist|Building Unit 114=0.0 1_Bdrm_7_3 0.00 res sink schedule 25 can't inspect schedule.
res sink dist|Building Unit 115=0.0 Service Hot Water Loop res sink dist|Building Unit 115=0.0 1_Bdrm_1_4 0.00 res sink schedule 26 can't inspect schedule.
res sink dist|Building Unit 116=0.0 Service Hot Water Loop res sink dist|Building Unit 116=0.0 1_Bdrm_2_4 0.00 res sink schedule 27 can't inspect schedule.
res sink dist|Building Unit 117=0.0 Service Hot Water Loop res sink dist|Building Unit 117=0.0 1_Bdrm_3_4 0.00 res sink schedule 28 can't inspect schedule.
res sink dist|Building Unit 118=0.0 Service Hot Water Loop res sink dist|Building Unit 118=0.0 1_Bdrm_4_4 0.00 res sink schedule 29 can't inspect schedule.
res sink dist|Building Unit 119=0.0 Service Hot Water Loop res sink dist|Building Unit 119=0.0 1_Bdrm_5_4 0.00 res sink schedule 30 can't inspect schedule.
res sink dist|Building Unit 120=0.0 Service Hot Water Loop res sink dist|Building Unit 120=0.0 1_Bdrm_6_4 0.00 res sink schedule 31 can't inspect schedule.
res sink dist|Building Unit 121=0.0 Service Hot Water Loop res sink dist|Building Unit 121=0.0 1_Bdrm_7_4 0.00 res sink schedule 32 can't inspect schedule.
res sink dist|Building Unit 201=0.0 Service Hot Water Loop res sink dist|Building Unit 201=0.0 2_Bdrm_1_2 0.00 res sink schedule 33 can't inspect schedule.
res sink dist|Building Unit 202=0.0 Service Hot Water Loop res sink dist|Building Unit 202=0.0 2_Bdrm_2_2 0.00 res sink schedule 34 can't inspect schedule.
res sink dist|Building Unit 203=0.0 Service Hot Water Loop res sink dist|Building Unit 203=0.0 2_Bdrm_3_2 0.00 res sink schedule 35 can't inspect schedule.
res sink dist|Building Unit 204=0.0 Service Hot Water Loop res sink dist|Building Unit 204=0.0 2_Bdrm_1_3 0.00 res sink schedule 36 can't inspect schedule.
res sink dist|Building Unit 205=0.0 Service Hot Water Loop res sink dist|Building Unit 205=0.0 2_Bdrm_2_3 0.00 res sink schedule 37 can't inspect schedule.
res sink dist|Building Unit 206=0.0 Service Hot Water Loop res sink dist|Building Unit 206=0.0 2_Bdrm_3_3 0.00 res sink schedule 38 can't inspect schedule.
res sink dist|Building Unit 207=0.0 Service Hot Water Loop res sink dist|Building Unit 207=0.0 2_Bdrm_1_4 0.00 res sink schedule 39 can't inspect schedule.
res sink dist|Building Unit 208=0.0 Service Hot Water Loop res sink dist|Building Unit 208=0.0 2_Bdrm_2_4 0.00 res sink schedule 40 can't inspect schedule.
res sink dist|Building Unit 209=0.0 Service Hot Water Loop res sink dist|Building Unit 209=0.0 2_Bdrm_3_4 0.00 res sink schedule 41 can't inspect schedule.
res sink dist|Building Unit 301=0.0 Service Hot Water Loop res sink dist|Building Unit 301=0.0 3_Bdrm_2_2 0.00 res sink schedule 42 can't inspect schedule.
res sink dist|Building Unit 302=0.0 Service Hot Water Loop res sink dist|Building Unit 302=0.0 3_Bdrm_1_3 0.00 res sink schedule 43 can't inspect schedule.
res sink dist|Building Unit 303=0.0 Service Hot Water Loop res sink dist|Building Unit 303=0.0 3_Bdrm_1_4 0.00 res sink schedule 44 can't inspect schedule.
res sink|Building Unit 001 Service Hot Water Loop res sink|Building Unit 001 0_Bdrm_1_2 2.46 res sink schedule can't inspect schedule.
res sink|Building Unit 002 Service Hot Water Loop res sink|Building Unit 002 0_Bdrm_2_2 2.46 res sink schedule 1 can't inspect schedule.
res sink|Building Unit 003 Service Hot Water Loop res sink|Building Unit 003 0_Bdrm_3_2 2.46 res sink schedule 2 can't inspect schedule.
res sink|Building Unit 004 Service Hot Water Loop res sink|Building Unit 004 0_Bdrm_4_2 2.46 res sink schedule 3 can't inspect schedule.
res sink|Building Unit 005 Service Hot Water Loop res sink|Building Unit 005 0_Bdrm_1_3 2.46 res sink schedule 4 can't inspect schedule.
res sink|Building Unit 006 Service Hot Water Loop res sink|Building Unit 006 0_Bdrm_2_3 2.46 res sink schedule 5 can't inspect schedule.
res sink|Building Unit 007 Service Hot Water Loop res sink|Building Unit 007 0_Bdrm_3_3 2.46 res sink schedule 6 can't inspect schedule.
res sink|Building Unit 008 Service Hot Water Loop res sink|Building Unit 008 0_Bdrm_4_3 2.46 res sink schedule 7 can't inspect schedule.
res sink|Building Unit 009 Service Hot Water Loop res sink|Building Unit 009 0_Bdrm_1_4 2.46 res sink schedule 8 can't inspect schedule.
res sink|Building Unit 010 Service Hot Water Loop res sink|Building Unit 010 0_Bdrm_2_4 2.46 res sink schedule 9 can't inspect schedule.
res sink|Building Unit 011 Service Hot Water Loop res sink|Building Unit 011 0_Bdrm_3_4 2.46 res sink schedule 10 can't inspect schedule.
res sink|Building Unit 012 Service Hot Water Loop res sink|Building Unit 012 0_Bdrm_4_4 2.46 res sink schedule 11 can't inspect schedule.
res sink|Building Unit 101 Service Hot Water Loop res sink|Building Unit 101 1_Bdrm_1_2 3.28 res sink schedule 12 can't inspect schedule.
res sink|Building Unit 102 Service Hot Water Loop res sink|Building Unit 102 1_Bdrm_2_2 3.28 res sink schedule 13 can't inspect schedule.
res sink|Building Unit 103 Service Hot Water Loop res sink|Building Unit 103 1_Bdrm_3_2 3.28 res sink schedule 14 can't inspect schedule.
res sink|Building Unit 104 Service Hot Water Loop res sink|Building Unit 104 1_Bdrm_4_2 3.28 res sink schedule 15 can't inspect schedule.
res sink|Building Unit 105 Service Hot Water Loop res sink|Building Unit 105 1_Bdrm_5_2 3.28 res sink schedule 16 can't inspect schedule.
res sink|Building Unit 106 Service Hot Water Loop res sink|Building Unit 106 1_Bdrm_6_2 3.28 res sink schedule 17 can't inspect schedule.
res sink|Building Unit 107 Service Hot Water Loop res sink|Building Unit 107 1_Bdrm_7_2 3.28 res sink schedule 18 can't inspect schedule.
res sink|Building Unit 108 Service Hot Water Loop res sink|Building Unit 108 1_Bdrm_1_3 3.28 res sink schedule 19 can't inspect schedule.
res sink|Building Unit 109 Service Hot Water Loop res sink|Building Unit 109 1_Bdrm_2_3 3.28 res sink schedule 20 can't inspect schedule.
res sink|Building Unit 110 Service Hot Water Loop res sink|Building Unit 110 1_Bdrm_3_3 3.28 res sink schedule 21 can't inspect schedule.
res sink|Building Unit 111 Service Hot Water Loop res sink|Building Unit 111 1_Bdrm_4_3 3.28 res sink schedule 22 can't inspect schedule.
res sink|Building Unit 112 Service Hot Water Loop res sink|Building Unit 112 1_Bdrm_5_3 3.28 res sink schedule 23 can't inspect schedule.
res sink|Building Unit 113 Service Hot Water Loop res sink|Building Unit 113 1_Bdrm_6_3 3.28 res sink schedule 24 can't inspect schedule.
res sink|Building Unit 114 Service Hot Water Loop res sink|Building Unit 114 1_Bdrm_7_3 3.28 res sink schedule 25 can't inspect schedule.
res sink|Building Unit 115 Service Hot Water Loop res sink|Building Unit 115 1_Bdrm_1_4 3.28 res sink schedule 26 can't inspect schedule.
res sink|Building Unit 116 Service Hot Water Loop res sink|Building Unit 116 1_Bdrm_2_4 3.28 res sink schedule 27 can't inspect schedule.
res sink|Building Unit 117 Service Hot Water Loop res sink|Building Unit 117 1_Bdrm_3_4 3.28 res sink schedule 28 can't inspect schedule.
res sink|Building Unit 118 Service Hot Water Loop res sink|Building Unit 118 1_Bdrm_4_4 3.28 res sink schedule 29 can't inspect schedule.
res sink|Building Unit 119 Service Hot Water Loop res sink|Building Unit 119 1_Bdrm_5_4 3.28 res sink schedule 30 can't inspect schedule.
res sink|Building Unit 120 Service Hot Water Loop res sink|Building Unit 120 1_Bdrm_6_4 3.28 res sink schedule 31 can't inspect schedule.
res sink|Building Unit 121 Service Hot Water Loop res sink|Building Unit 121 1_Bdrm_7_4 3.28 res sink schedule 32 can't inspect schedule.
res sink|Building Unit 201 Service Hot Water Loop res sink|Building Unit 201 2_Bdrm_1_2 3.28 res sink schedule 33 can't inspect schedule.
res sink|Building Unit 202 Service Hot Water Loop res sink|Building Unit 202 2_Bdrm_2_2 3.28 res sink schedule 34 can't inspect schedule.
res sink|Building Unit 203 Service Hot Water Loop res sink|Building Unit 203 2_Bdrm_3_2 3.28 res sink schedule 35 can't inspect schedule.
res sink|Building Unit 204 Service Hot Water Loop res sink|Building Unit 204 2_Bdrm_1_3 3.28 res sink schedule 36 can't inspect schedule.
res sink|Building Unit 205 Service Hot Water Loop res sink|Building Unit 205 2_Bdrm_2_3 3.28 res sink schedule 37 can't inspect schedule.
res sink|Building Unit 206 Service Hot Water Loop res sink|Building Unit 206 2_Bdrm_3_3 3.28 res sink schedule 38 can't inspect schedule.
res sink|Building Unit 207 Service Hot Water Loop res sink|Building Unit 207 2_Bdrm_1_4 3.28 res sink schedule 39 can't inspect schedule.
res sink|Building Unit 208 Service Hot Water Loop res sink|Building Unit 208 2_Bdrm_2_4 3.28 res sink schedule 40 can't inspect schedule.
res sink|Building Unit 209 Service Hot Water Loop res sink|Building Unit 209 2_Bdrm_3_4 3.28 res sink schedule 41 can't inspect schedule.
res sink|Building Unit 301 Service Hot Water Loop res sink|Building Unit 301 3_Bdrm_2_2 3.37 res sink schedule 42 can't inspect schedule.
res sink|Building Unit 302 Service Hot Water Loop res sink|Building Unit 302 3_Bdrm_1_3 3.37 res sink schedule 43 can't inspect schedule.
res sink|Building Unit 303 Service Hot Water Loop res sink|Building Unit 303 3_Bdrm_1_4 3.37 res sink schedule 44 can't inspect schedule.

HVAC Load Profiles


Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Average Outdoor Air Dry Bulb (F) 56.7 57.6 58.2 60.4 62.6 64.7 67.8 68.1 67.7 64.7 61.2 57.8
Cooling Load (MBtu) 15.46 14.6 11.62 19.69 29.26 46.31 75.6 80.92 82.81 49.38 29.28 17.0
Heating Load (MBtu) 23.07 16.8 17.77 12.87 9.48 6.17 5.43 5.3 5.49 8.12 12.33 17.9

Zone Conditions


Zone Unmet Htg (hr) Unmet Htg - Occ (hr) < 56 (F) 56-61 (F) 61-66 (F) 66-68 (F) 68-70 (F) 70-72 (F) 72-74 (F) 74-76 (F) 76-78 (F) 78-83 (F) 83-88 (F) >= 88 (F) Unmet Clg (hr) Unmet Clg - Occ (hr) Mean Temp (F)
0_BDRM_1_2 0 0 0 0 0 0 0 97 631 2100 5932 0 0 0 0 0 75.3 (F)
0_BDRM_1_3 0 0 0 0 0 0 0 0 7 210 8543 0 0 0 0 0 75.9 (F)
0_BDRM_1_4 0 0 0 0 0 0 0 84 279 1200 7197 0 0 0 0 0 75.6 (F)
0_BDRM_2_2 0 0 0 0 0 0 0 433 1651 2361 4315 0 0 0 0 0 74.6 (F)
0_BDRM_2_3 0 0 0 0 0 0 0 0 60 723 7977 0 0 0 0 0 75.8 (F)
0_BDRM_2_4 0 0 0 0 0 0 0 250 747 1630 6133 0 0 0 0 0 75.2 (F)
0_BDRM_3_2 0 0 0 0 0 0 0 168 1196 2591 4805 0 0 0 0 0 74.9 (F)
0_BDRM_3_3 0 0 0 0 0 0 0 0 18 415 8327 0 0 0 0 0 75.9 (F)
0_BDRM_3_4 0 0 0 0 0 0 0 146 536 1427 6651 0 0 0 0 0 75.4 (F)
0_BDRM_4_2 0 0 0 0 0 0 0 135 1099 2606 4920 0 0 0 0 0 75.0 (F)
0_BDRM_4_3 0 0 0 0 0 0 0 0 12 351 8397 0 0 0 0 0 75.9 (F)
0_BDRM_4_4 0 0 0 0 0 0 0 145 486 1424 6705 0 0 0 0 0 75.4 (F)
1_BDRM_1_2 0 0 0 0 0 0 0 86 481 2025 6168 0 0 0 0 0 75.4 (F)
1_BDRM_1_3 0 0 0 0 0 0 0 0 6 184 8570 0 0 0 0 0 75.9 (F)
1_BDRM_1_4 0 0 0 0 0 0 0 92 289 1227 7152 0 0 0 0 0 75.6 (F)
1_BDRM_2_2 0 0 0 0 0 0 0 48 361 1902 6449 0 0 0 0 0 75.4 (F)
1_BDRM_2_3 0 0 0 0 0 0 0 0 0 122 8638 0 0 0 0 0 76.0 (F)
1_BDRM_2_4 0 0 0 0 0 0 0 77 189 1105 7389 0 0 0 0 0 75.7 (F)
1_BDRM_3_2 0 0 0 0 0 0 0 65 409 1999 6287 0 0 0 0 0 75.4 (F)
1_BDRM_3_3 0 0 0 0 0 0 0 0 0 123 8637 0 0 0 0 0 76.0 (F)
1_BDRM_3_4 0 0 0 0 0 0 0 78 184 1085 7413 0 0 0 0 0 75.7 (F)
1_BDRM_4_2 0 0 0 0 0 0 0 956 2288 1809 3707 0 0 0 0 0 74.2 (F)
1_BDRM_4_3 0 0 0 0 0 0 0 10 203 1077 7470 0 0 0 0 0 75.7 (F)
1_BDRM_4_4 0 0 0 0 0 0 0 418 988 1914 5440 0 0 0 0 0 75.0 (F)
1_BDRM_5_2 0 0 0 0 0 0 0 652 2037 2101 3970 0 0 0 0 0 74.4 (F)
1_BDRM_5_3 0 0 0 0 0 0 0 0 108 863 7789 0 0 0 0 0 75.8 (F)
1_BDRM_5_4 0 0 0 0 0 0 0 348 864 1915 5633 0 0 0 0 0 75.1 (F)
1_BDRM_6_2 0 0 0 0 0 0 0 154 1220 2633 4753 0 0 0 0 0 74.9 (F)
1_BDRM_6_3 0 0 0 0 0 0 0 0 23 434 8303 0 0 0 0 0 75.9 (F)
1_BDRM_6_4 0 0 0 0 0 0 0 152 552 1436 6620 0 0 0 0 0 75.4 (F)
1_BDRM_7_2 0 0 0 0 0 0 0 135 784 2349 5492 0 0 0 0 0 75.1 (F)
1_BDRM_7_3 0 0 0 0 0 0 0 0 6 290 8464 0 0 0 0 0 75.9 (F)
1_BDRM_7_4 0 0 0 0 0 0 0 101 303 1398 6958 0 0 0 0 0 75.5 (F)
2_BDRM_1_2 0 0 0 0 0 0 0 572 1543 2240 4405 0 0 0 0 0 74.6 (F)
2_BDRM_1_3 0 0 0 0 0 0 0 55 175 1340 7190 0 0 0 0 0 75.6 (F)
2_BDRM_1_4 0 0 0 0 0 0 0 465 914 1799 5582 0 0 0 0 0 75.0 (F)
2_BDRM_2_2 0 0 0 0 0 0 0 1797 2003 1574 3386 0 0 0 0 0 73.8 (F)
2_BDRM_2_3 0 0 0 0 0 0 0 262 829 1983 5686 0 0 0 0 0 75.1 (F)
2_BDRM_2_4 0 0 0 0 0 0 0 1061 1320 1948 4431 0 0 0 0 0 74.5 (F)
2_BDRM_3_2 0 0 0 0 0 0 0 819 2018 1865 4058 0 0 0 0 0 74.3 (F)
2_BDRM_3_3 0 0 0 0 0 0 0 194 765 2050 5751 0 0 0 0 0 75.2 (F)
2_BDRM_3_4 0 0 0 0 0 0 0 1041 1439 2022 4258 0 0 0 0 0 74.4 (F)
3_BDRM_1_3 0 0 0 0 0 0 0 72 228 1407 7053 0 0 0 0 0 75.6 (F)
3_BDRM_1_4 0 0 0 0 0 0 0 609 1081 1925 5145 0 0 0 0 0 74.8 (F)
3_BDRM_2_2 0 0 0 0 0 0 0 461 1545 2222 4532 0 0 0 0 0 74.7 (F)
BATHRM_1 0 0 0 0 0 0 0 2335 2342 4083 0 0 0 0 0 0 73.0 (F)
BATHRM_2 0 0 0 0 0 0 0 2500 2245 4015 0 0 0 0 0 0 72.9 (F)
COFFEE_SHOP 0 0 0 24 251 388 213 3502 1210 3172 0 0 0 0 0 0 71.8 (F)
COMMUNITY_RM 0 0 0 0 0 0 0 5122 1398 2240 0 0 0 0 0 0 71.7 (F)
CORRIDOR 1 0 0 0 0 0 0 63 1219 2572 2323 2583 0 0 0 0 0 73.9 (F)
CORRIDOR_2 0 0 0 0 0 0 0 0 396 2768 5596 0 0 0 0 0 75.9 (F)
CORRIDOR_3 0 0 0 0 0 0 0 0 0 53 8707 0 0 0 0 0 77.7 (F)
CORRIDOR_4 0 0 0 0 0 0 0 25 252 1045 7366 72 0 0 0 0 76.7 (F)
ELEVATOR_1 0 0 0 0 0 22 887 2572 1951 1816 1512 0 0 0 0 0 72.6 (F)
ELEVATOR_1_2 0 0 0 0 0 0 0 514 3028 1930 3288 0 0 0 0 0 74.3 (F)
ELEVATOR_1_3 0 0 0 0 0 0 0 0 150 890 7720 0 0 0 0 0 76.4 (F)
ELEVATOR_1_4 0 0 0 0 0 0 0 30 424 1243 5147 1916 0 0 0 0 77.0 (F)
ELEVATOR_2 0 0 0 0 0 6 353 1843 2418 2399 1741 0 0 0 0 0 73.2 (F)
ELEVATOR_2_2 0 0 0 0 0 0 0 94 1294 3221 4151 0 0 0 0 0 75.0 (F)
ELEVATOR_2_3 0 0 0 0 0 0 0 0 20 176 8564 0 0 0 0 0 76.8 (F)
ELEVATOR_2_4 0 0 0 0 0 0 0 13 144 784 5225 2594 0 0 0 0 77.6 (F)
GARBAGE 1 0 0 0 0 0 991 2198 1912 1793 1445 421 0 0 0 0 0 71.0 (F)
GYM 1 0 0 0 0 0 0 0 3807 1366 3587 0 0 0 0 0 0 72.5 (F)
LOBBY_ENTRY 0 0 0 0 11 753 797 2271 1865 1271 1616 176 0 0 0 0 72.3 (F)
LT_RETAIL_1 0 0 0 0 69 1166 969 2041 1765 2750 0 0 0 0 0 0 71.5 (F)
LT_RETAIL_2 0 0 0 0 128 1217 922 2013 1626 2847 7 0 0 0 0 0 71.4 (F)
LT_RETAIL_3 0 0 0 0 113 1304 904 2410 1796 2233 0 0 0 0 0 0 71.1 (F)
LT_RETAIL_4 0 0 0 0 231 1272 850 2426 1675 2306 0 0 0 0 0 0 71.0 (F)
MAIL_SHIPPING 0 0 0 0 2 1423 2101 1671 1732 1414 417 0 0 0 0 0 70.8 (F)
OFFICE 1 0 0 0 0 0 115 817 1845 1580 3808 593 2 0 0 0 0 72.9 (F)
STAIRWELL_1_2 0 0 0 0 0 9 434 1820 1975 2128 2394 0 0 0 0 0 73.4 (F)
STAIRWELL_1_3 0 0 0 0 0 0 14 217 1067 2893 4569 0 0 0 0 0 75.0 (F)
STAIRWELL_1_4 0 0 0 0 0 91 413 1020 1713 2607 2898 18 0 0 0 0 74.0 (F)
STAIRWELL_2_2 0 0 0 0 0 3 110 630 2072 2577 3361 7 0 0 0 0 74.3 (F)
STAIRWELL_2_3 0 0 0 0 0 0 1 61 264 2116 6087 231 0 0 0 0 75.9 (F)
STAIRWELL_2_4 0 0 0 0 0 34 181 624 1276 2630 3571 441 3 0 0 0 74.9 (F)
STAIR_1 0 0 0 0 0 71 758 1774 2004 2256 1893 4 0 0 0 0 73.1 (F)
STAIR_2 0 0 0 0 0 130 1355 2431 1768 1774 1302 0 0 0 0 0 72.3 (F)

Zone < 30 (%) 30-35 (%) 35-40 (%) 40-45 (%) 45-50 (%) 50-55 (%) 55-60 (%) 60-65 (%) 65-70 (%) 70-75 (%) 75-80 (%) >= 80 (%) Mean Relative Humidity (%)
0_BDRM_1_2 360 337 673 938 1844 2991 1333 262 22 0 0 0 48.4 (%)
0_BDRM_1_3 389 486 698 2762 2187 2098 138 2 0 0 0 0 44.8 (%)
0_BDRM_1_4 429 445 705 2145 2344 1755 842 95 0 0 0 0 45.8 (%)
0_BDRM_2_2 291 286 568 724 1571 2845 1815 592 65 3 0 0 50.1 (%)
0_BDRM_2_3 390 454 727 1957 2554 2480 188 10 0 0 0 0 45.5 (%)
0_BDRM_2_4 322 336 641 1275 2161 2451 1260 312 2 0 0 0 48.0 (%)
0_BDRM_3_2 311 312 616 772 1653 2992 1558 528 18 0 0 0 49.5 (%)
0_BDRM_3_3 404 476 745 2167 2275 2474 218 1 0 0 0 0 45.4 (%)
0_BDRM_3_4 348 339 662 1465 2272 2437 990 243 4 0 0 0 47.4 (%)
0_BDRM_4_2 319 307 592 751 1598 3046 1628 502 17 0 0 0 49.6 (%)
0_BDRM_4_3 416 459 748 2219 2214 2515 177 12 0 0 0 0 45.3 (%)
0_BDRM_4_4 371 360 704 1346 2409 2445 961 164 0 0 0 0 47.2 (%)
1_BDRM_1_2 250 317 531 852 1544 2785 1962 501 17 1 0 0 50.0 (%)
1_BDRM_1_3 309 363 660 2098 2476 2159 640 55 0 0 0 0 46.2 (%)
1_BDRM_1_4 256 347 640 1400 2170 2174 1239 497 37 0 0 0 48.3 (%)
1_BDRM_2_2 238 272 541 892 1453 2655 2200 494 14 1 0 0 50.2 (%)
1_BDRM_2_3 293 353 703 2068 2412 2103 785 43 0 0 0 0 46.4 (%)
1_BDRM_2_4 253 334 612 1326 2317 2357 1170 388 3 0 0 0 48.2 (%)
1_BDRM_3_2 268 311 602 860 1541 2693 2021 454 8 2 0 0 49.8 (%)
1_BDRM_3_3 293 353 703 2046 2414 2097 811 43 0 0 0 0 46.4 (%)
1_BDRM_3_4 257 351 619 1439 2136 2234 1263 458 3 0 0 0 48.3 (%)
1_BDRM_4_2 228 245 441 641 1005 2030 2612 1217 326 13 2 0 52.6 (%)
1_BDRM_4_3 351 369 699 1151 2101 2716 1344 29 0 0 0 0 47.7 (%)
1_BDRM_4_4 272 265 592 919 1755 2659 1489 712 97 0 0 0 49.8 (%)
1_BDRM_5_2 220 228 455 623 949 1926 2627 1354 366 12 0 0 52.9 (%)
1_BDRM_5_3 361 410 691 1208 2205 2617 1203 65 0 0 0 0 47.5 (%)
1_BDRM_5_4 273 291 579 888 1746 2602 1567 715 99 0 0 0 49.9 (%)
1_BDRM_6_2 207 233 435 691 1135 2414 2387 1096 157 5 0 0 52.0 (%)
1_BDRM_6_3 271 344 630 1237 2381 2578 1271 48 0 0 0 0 47.8 (%)
1_BDRM_6_4 243 250 524 994 1980 2602 1479 650 38 0 0 0 49.7 (%)
1_BDRM_7_2 281 331 616 766 1313 2481 2100 812 56 4 0 0 50.4 (%)
1_BDRM_7_3 402 474 750 1865 2124 2315 825 5 0 0 0 0 46.1 (%)
1_BDRM_7_4 328 359 692 1336 1987 2238 1140 605 75 0 0 0 48.3 (%)
2_BDRM_1_2 303 306 555 766 1159 2255 2017 1076 304 19 0 0 51.3 (%)
2_BDRM_1_3 378 405 711 1435 1911 2078 1286 525 31 0 0 0 47.8 (%)
2_BDRM_1_4 303 362 626 1475 1650 1859 1414 782 271 18 0 0 49.3 (%)
2_BDRM_2_2 250 228 464 682 1119 2075 2112 1306 483 40 1 0 52.6 (%)
2_BDRM_2_3 346 347 665 1222 1928 2313 1305 587 47 0 0 0 48.5 (%)
2_BDRM_2_4 300 290 566 1279 1629 2042 1490 849 292 23 0 0 49.9 (%)
2_BDRM_3_2 250 264 464 712 1177 2468 2124 1005 283 13 0 0 51.7 (%)
2_BDRM_3_3 321 331 632 1040 1833 2353 1500 676 74 0 0 0 49.2 (%)
2_BDRM_3_4 294 284 548 1031 1553 1997 1617 987 409 40 0 0 50.8 (%)
3_BDRM_1_3 359 393 703 1314 2007 2173 1326 471 14 0 0 0 48.0 (%)
3_BDRM_1_4 311 324 628 1110 1597 1975 1543 910 338 24 0 0 50.1 (%)
3_BDRM_2_2 311 318 577 801 1306 2365 1939 939 193 11 0 0 50.7 (%)
BATHRM_1 328 377 639 716 1119 2103 1951 1198 297 32 0 0 51.1 (%)
BATHRM_2 328 366 637 726 1124 2086 1918 1204 331 40 0 0 51.2 (%)
COFFEE_SHOP 315 274 378 463 564 845 1264 1648 1628 1065 281 35 58.1 (%)
COMMUNITY_RM 393 268 411 461 723 1001 1208 1644 1613 850 186 2 56.8 (%)
CORRIDOR 1 0 146 988 1725 1916 1434 1785 724 42 0 0 0 49.4 (%)
CORRIDOR_2 0 0 3551 5028 181 0 0 0 0 0 0 0 40.9 (%)
CORRIDOR_3 0 0 8366 394 0 0 0 0 0 0 0 0 38.5 (%)
CORRIDOR_4 0 0 5716 2871 173 0 0 0 0 0 0 0 39.7 (%)
ELEVATOR_1 0 0 219 3380 4109 1052 0 0 0 0 0 0 45.8 (%)
ELEVATOR_1_2 0 0 1402 4346 3012 0 0 0 0 0 0 0 43.2 (%)
ELEVATOR_1_3 0 0 4998 3671 91 0 0 0 0 0 0 0 40.2 (%)
ELEVATOR_1_4 0 0 5523 2949 288 0 0 0 0 0 0 0 39.5 (%)
ELEVATOR_2 0 0 439 4192 3672 457 0 0 0 0 0 0 44.8 (%)
ELEVATOR_2_2 0 0 1663 6258 839 0 0 0 0 0 0 0 42.1 (%)
ELEVATOR_2_3 0 0 7005 1751 4 0 0 0 0 0 0 0 39.6 (%)
ELEVATOR_2_4 0 4 6571 2085 100 0 0 0 0 0 0 0 38.7 (%)
GARBAGE 1 402 303 485 565 814 1430 1874 1747 876 255 9 0 53.7 (%)
GYM 1 357 308 404 476 684 1103 1413 1793 1568 554 97 3 56.1 (%)
LOBBY_ENTRY 426 329 452 504 649 1215 1592 1970 1228 370 25 0 54.8 (%)
LT_RETAIL_1 370 293 413 478 634 1152 1555 2018 1394 395 58 0 55.7 (%)
LT_RETAIL_2 366 295 410 478 644 1165 1607 2077 1262 408 48 0 55.6 (%)
LT_RETAIL_3 333 284 384 455 589 1090 1519 2021 1474 520 91 0 56.4 (%)
LT_RETAIL_4 327 272 380 463 602 1116 1634 2084 1303 484 95 0 56.2 (%)
MAIL_SHIPPING 382 287 458 572 747 1415 1926 1779 905 279 10 0 54.1 (%)
OFFICE 1 512 458 601 855 1445 1828 1657 1097 286 21 0 0 49.7 (%)
STAIRWELL_1_2 491 433 646 793 1414 1907 1809 1015 246 6 0 0 49.7 (%)
STAIRWELL_1_3 672 593 737 1328 1478 1565 1559 683 145 0 0 0 47.2 (%)
STAIRWELL_1_4 541 481 652 1044 1530 1760 1646 877 229 0 0 0 48.8 (%)
STAIRWELL_2_2 654 554 698 836 1491 1772 1733 863 159 0 0 0 48.3 (%)
STAIRWELL_2_3 885 686 747 1385 1386 1521 1470 588 92 0 0 0 46.0 (%)
STAIRWELL_2_4 744 594 672 1081 1562 1613 1526 801 167 0 0 0 47.5 (%)
STAIR_1 515 487 658 655 1259 1601 1917 1257 383 28 0 0 50.4 (%)
STAIR_2 400 357 608 664 1186 1666 1943 1358 527 51 0 0 51.6 (%)

Zone Overview


Area (ft^2) Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume (ft^3) Multiplier Above Ground Gross Wall Area (ft^2) Underground Gross Wall Area (ft^2) Window Glass Area (ft^2) Lighting (W/ft^2) People (ft^2/person) Plug and Process (W/ft^2)
0_BDRM_1_2 450.04 Yes Yes 4500.15 1.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_1_3 450.04 Yes Yes 4500.15 2.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_1_4 450.04 Yes Yes 4500.15 1.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_2_2 450.04 Yes Yes 4500.15 1.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_2_3 450.04 Yes Yes 4500.15 2.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_2_4 450.04 Yes Yes 4500.15 1.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_3_2 450.04 Yes Yes 4500.15 1.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_3_3 450.04 Yes Yes 4500.15 2.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_3_4 450.04 Yes Yes 4500.15 1.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_4_2 450.04 Yes Yes 4500.15 1.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_4_3 450.04 Yes Yes 4500.15 2.00 150.05 0.0 44.99 0.21 714.29 139.08
0_BDRM_4_4 450.04 Yes Yes 4500.15 1.00 150.05 0.0 44.99 0.21 714.29 139.08
1_BDRM_1_2 599.98 Yes Yes 5999.96 1.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_1_3 599.98 Yes Yes 5999.96 2.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_1_4 599.98 Yes Yes 5999.96 1.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_2_2 599.98 Yes Yes 5999.96 1.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_2_3 599.98 Yes Yes 5999.96 2.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_2_4 599.98 Yes Yes 5999.96 1.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_3_2 599.98 Yes Yes 5999.96 1.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_3_3 599.98 Yes Yes 5999.96 2.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_3_4 599.98 Yes Yes 5999.96 1.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_4_2 750.03 Yes Yes 7500.13 1.00 250.05 0.0 75.02 0.16 483.84 111.22
1_BDRM_4_3 750.03 Yes Yes 7500.13 2.00 250.05 0.0 75.02 0.16 483.84 111.22
1_BDRM_4_4 750.03 Yes Yes 7500.13 1.00 250.05 0.0 75.02 0.16 483.84 111.22
1_BDRM_5_2 750.03 Yes Yes 7500.13 1.00 250.05 0.0 75.02 0.16 483.84 111.22
1_BDRM_5_3 750.03 Yes Yes 7500.13 2.00 250.05 0.0 75.02 0.16 483.84 111.22
1_BDRM_5_4 750.03 Yes Yes 7500.13 1.00 250.05 0.0 75.02 0.16 483.84 111.22
1_BDRM_6_2 599.98 Yes Yes 5999.96 1.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_6_3 599.98 Yes Yes 5999.96 2.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_6_4 599.98 Yes Yes 5999.96 1.00 199.99 0.0 59.95 0.18 387.07 139.01
1_BDRM_7_2 750.03 Yes Yes 7500.13 1.00 250.05 0.0 75.02 0.16 483.84 111.22
1_BDRM_7_3 750.03 Yes Yes 7500.13 2.00 250.05 0.0 75.02 0.16 483.84 111.22
1_BDRM_7_4 750.03 Yes Yes 7500.13 1.00 250.05 0.0 75.02 0.16 483.84 111.22
2_BDRM_1_2 1099.96 Yes Yes 11000.17 1.00 699.98 0.0 210.0 0.14 445.3 87.51
2_BDRM_1_3 1099.96 Yes Yes 11000.17 2.00 699.98 0.0 210.0 0.14 445.3 87.51
2_BDRM_1_4 1099.96 Yes Yes 11000.17 1.00 699.98 0.0 210.0 0.14 445.3 87.51
2_BDRM_2_2 1199.96 Yes Yes 11999.92 1.00 750.03 0.0 224.97 0.14 485.88 80.22
2_BDRM_2_3 1199.96 Yes Yes 11999.92 2.00 750.03 0.0 224.97 0.14 485.88 80.22
2_BDRM_2_4 1199.96 Yes Yes 11999.92 1.00 750.03 0.0 224.97 0.14 485.88 80.22
2_BDRM_3_2 1150.02 Yes Yes 11499.87 1.00 699.98 0.0 210.0 0.14 465.54 83.71
2_BDRM_3_3 1150.02 Yes Yes 11499.87 2.00 699.98 0.0 210.0 0.14 465.54 83.71
2_BDRM_3_4 1150.02 Yes Yes 11499.87 1.00 699.98 0.0 210.0 0.14 465.54 83.71
3_BDRM_1_3 1499.95 Yes Yes 14999.9 2.00 799.97 0.0 240.04 0.13 442.5 73.48
3_BDRM_1_4 1499.95 Yes Yes 14999.9 1.00 799.97 0.0 240.04 0.13 442.5 73.48
3_BDRM_2_2 1499.95 Yes Yes 14999.9 1.00 799.97 0.0 240.04 0.13 442.5 73.48
BATHRM_1 150.05 Yes Yes 2100.16 1.00 0.0 0.0 0.0 0.4 350.9 0.0
BATHRM_2 150.05 Yes Yes 2100.16 1.00 0.0 0.0 0.0 0.4 350.9 0.0
COFFEE_SHOP 1499.95 Yes Yes 20999.87 1.00 1119.98 0.0 336.05 0.4 14.32 0.5
COMMUNITY_RM 1499.95 Yes Yes 20999.87 1.00 699.98 0.0 210.0 0.3 20.02 0.57
CORRIDOR 1 999.97 Yes Yes 14000.15 1.00 140.04 0.0 41.98 0.4 0.0 0.0
CORRIDOR_2 799.97 Yes Yes 7999.83 1.00 0.0 0.0 0.0 0.4 0.0 0.0
CORRIDOR_3 799.97 Yes Yes 7999.83 2.00 0.0 0.0 0.0 0.4 0.0 0.0
CORRIDOR_4 799.97 Yes Yes 7999.83 1.00 0.0 0.0 0.0 0.4 0.0 0.0
ELEVATOR_1 100.0 No Yes 1399.87 1.00 0.0 0.0 0.0 0.0 0.0 0.0
ELEVATOR_1_2 100.0 No Yes 1000.11 1.00 0.0 0.0 0.0 0.0 0.0 0.0
ELEVATOR_1_3 100.0 No Yes 1000.11 2.00 0.0 0.0 0.0 0.0 0.0 0.0
ELEVATOR_1_4 100.0 No Yes 1000.11 1.00 0.0 0.0 0.0 0.0 0.0 204.33
ELEVATOR_2 100.0 No Yes 1399.87 1.00 0.0 0.0 0.0 0.0 0.0 0.0
ELEVATOR_2_2 100.0 No Yes 1000.11 1.00 0.0 0.0 0.0 0.0 0.0 0.0
ELEVATOR_2_3 100.0 No Yes 1000.11 2.00 0.0 0.0 0.0 0.0 0.0 0.0
ELEVATOR_2_4 100.0 No Yes 1000.11 1.00 0.0 0.0 0.0 0.0 0.0 204.33
GARBAGE 1 450.04 Yes Yes 6300.14 1.00 210.0 0.0 62.97 0.3 0.0 0.0
GYM 1 1050.02 Yes Yes 14700.08 1.00 909.98 0.0 272.97 0.3 50.16 1.73
LOBBY_ENTRY 599.98 Yes Yes 8399.95 1.00 420.01 0.0 126.05 0.4 66.63 0.3
LT_RETAIL_1 1350.01 Yes Yes 18900.06 1.00 630.01 0.0 189.01 0.5 66.63 0.3
LT_RETAIL_2 1099.96 Yes Yes 15400.02 1.00 979.95 0.0 293.96 0.5 66.63 0.3
LT_RETAIL_3 1050.02 Yes Yes 14700.08 1.00 489.97 0.0 147.04 0.5 66.63 0.3
LT_RETAIL_4 1099.96 Yes Yes 15400.02 1.00 979.95 0.0 293.96 0.5 66.63 0.3
MAIL_SHIPPING 450.04 Yes Yes 6300.14 1.00 210.0 0.0 62.97 0.3 0.0 0.0
OFFICE 1 750.03 Yes Yes 10500.11 1.00 350.04 0.0 104.95 0.3 473.93 0.62
STAIRWELL_1_2 299.99 Yes Yes 2999.98 1.00 100.0 0.0 30.03 0.4 0.0 0.0
STAIRWELL_1_3 299.99 Yes Yes 2999.98 2.00 100.0 0.0 30.03 0.4 0.0 0.0
STAIRWELL_1_4 299.99 Yes Yes 2999.98 1.00 100.0 0.0 30.03 0.4 0.0 0.0
STAIRWELL_2_2 299.99 Yes Yes 2999.98 1.00 100.0 0.0 30.03 0.4 0.0 0.0
STAIRWELL_2_3 299.99 Yes Yes 2999.98 2.00 100.0 0.0 30.03 0.4 0.0 0.0
STAIRWELL_2_4 299.99 Yes Yes 2999.98 1.00 100.0 0.0 30.03 0.4 0.0 0.0
STAIR_1 299.99 Yes Yes 4199.97 1.00 140.04 0.0 41.98 0.4 0.0 0.0
STAIR_2 299.99 Yes Yes 4199.97 1.00 140.04 0.0 41.98 0.4 0.0 0.0
Total 65000.03 702000.12 28620.05 0.0 8586.05 0.23 171.9 76.6
Conditioned Total 63999.95 691199.83 28620.05 0.0 8586.05 0.23 169.32 77.16
Unconditioned Total 999.97 10799.93 0.0 0.0 0.0 0.0 0.0 40.87
Not Part of Total 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Heating/Cooling Calculated Design Load Design Load With Sizing Factor Calculated Design Air Flow (ft^3/min) Design Air Flow With Sizing Factor (ft^3/min) Date/Time Of Peak Outdoor Temperature at Peak Load (F) Outdoor Humidity Ratio at Peak Load (lbWater/lbAir)
0_BDRM_1_2 Cooling 0.21 (ton) 0.24 (ton) 127.13 148.32 8/21 13:00:00 83.12 0.01
0_BDRM_1_2 Heating 0.87 (kBtu/h) 1.08 (kBtu/h) 23.31 29.66 1/21 08:30:00 44.42 0.01
0_BDRM_1_3 Cooling 0.38 (ton) 0.44 (ton) 233.08 269.1 8/21 13:15:00 83.25 0.01
0_BDRM_1_3 Heating 1.44 (kBtu/h) 1.8 (kBtu/h) 38.14 52.97 1/21 24:00:00 44.42 0.01
0_BDRM_1_4 Cooling 0.22 (ton) 0.26 (ton) 137.73 158.92 8/21 13:30:00 83.39 0.01
0_BDRM_1_4 Heating 1.08 (kBtu/h) 1.35 (kBtu/h) 29.66 36.02 1/21 24:00:00 44.42 0.01
0_BDRM_2_2 Cooling 0.19 (ton) 0.21 (ton) 114.42 131.37 8/21 15:00:00 83.66 0.01
0_BDRM_2_2 Heating 0.84 (kBtu/h) 1.05 (kBtu/h) 23.31 27.55 1/21 11:15:00 44.42 0.01
0_BDRM_2_3 Cooling 0.35 (ton) 0.41 (ton) 218.24 250.03 8/21 15:00:00 83.66 0.01
0_BDRM_2_3 Heating 1.47 (kBtu/h) 1.84 (kBtu/h) 40.26 52.97 1/21 24:00:00 44.42 0.01
0_BDRM_2_4 Cooling 0.2 (ton) 0.24 (ton) 127.13 144.08 8/21 15:15:00 83.5 0.01
0_BDRM_2_4 Heating 1.2 (kBtu/h) 1.5 (kBtu/h) 31.78 40.26 1/21 24:00:00 44.42 0.01
0_BDRM_3_2 Cooling 0.19 (ton) 0.21 (ton) 114.42 131.37 8/21 15:00:00 83.66 0.01
0_BDRM_3_2 Heating 0.75 (kBtu/h) 0.94 (kBtu/h) 19.07 25.43 1/21 09:15:00 44.42 0.01
0_BDRM_3_3 Cooling 0.33 (ton) 0.38 (ton) 203.41 235.2 8/21 15:00:00 83.66 0.01
0_BDRM_3_3 Heating 1.39 (kBtu/h) 1.74 (kBtu/h) 38.14 52.97 1/21 24:00:00 44.42 0.01
0_BDRM_3_4 Cooling 0.19 (ton) 0.22 (ton) 116.54 133.49 8/21 15:00:00 83.66 0.01
0_BDRM_3_4 Heating 1.08 (kBtu/h) 1.35 (kBtu/h) 29.66 36.02 1/21 24:00:00 44.42 0.01
0_BDRM_4_2 Cooling 0.19 (ton) 0.21 (ton) 114.42 131.37 8/21 15:00:00 83.66 0.01
0_BDRM_4_2 Heating 0.74 (kBtu/h) 0.93 (kBtu/h) 19.07 25.43 1/21 09:15:00 44.42 0.01
0_BDRM_4_3 Cooling 0.33 (ton) 0.38 (ton) 203.41 233.08 8/21 15:00:00 83.66 0.01
0_BDRM_4_3 Heating 1.38 (kBtu/h) 1.73 (kBtu/h) 38.14 52.97 1/21 24:00:00 44.42 0.01
0_BDRM_4_4 Cooling 0.19 (ton) 0.22 (ton) 116.54 133.49 8/21 15:00:00 83.66 0.01
0_BDRM_4_4 Heating 1.07 (kBtu/h) 1.34 (kBtu/h) 29.66 36.02 1/21 24:00:00 44.42 0.01
1_BDRM_1_2 Cooling 0.26 (ton) 0.3 (ton) 161.03 184.34 8/21 13:15:00 83.25 0.01
1_BDRM_1_2 Heating 1.11 (kBtu/h) 1.39 (kBtu/h) 29.66 38.14 1/21 09:15:00 44.42 0.01
1_BDRM_1_3 Cooling 0.51 (ton) 0.59 (ton) 315.71 364.45 8/21 13:15:00 83.25 0.01
1_BDRM_1_3 Heating 1.9 (kBtu/h) 2.38 (kBtu/h) 50.85 69.92 1/21 24:00:00 44.42 0.01
1_BDRM_1_4 Cooling 0.3 (ton) 0.34 (ton) 182.22 209.77 8/21 13:45:00 83.53 0.01
1_BDRM_1_4 Heating 1.54 (kBtu/h) 1.92 (kBtu/h) 40.26 50.85 1/21 24:00:00 44.42 0.01
1_BDRM_2_2 Cooling 0.27 (ton) 0.31 (ton) 163.15 188.58 8/21 13:15:00 83.25 0.01
1_BDRM_2_2 Heating 1.03 (kBtu/h) 1.28 (kBtu/h) 27.55 36.02 1/21 09:00:00 44.42 0.01
1_BDRM_2_3 Cooling 0.49 (ton) 0.56 (ton) 300.88 345.38 8/21 13:15:00 83.25 0.01
1_BDRM_2_3 Heating 1.83 (kBtu/h) 2.28 (kBtu/h) 48.73 69.92 1/21 24:00:00 44.42 0.01
1_BDRM_2_4 Cooling 0.28 (ton) 0.32 (ton) 171.63 197.06 8/21 13:30:00 83.39 0.01
1_BDRM_2_4 Heating 1.42 (kBtu/h) 1.77 (kBtu/h) 38.14 48.73 1/21 24:00:00 44.42 0.01
1_BDRM_3_2 Cooling 0.27 (ton) 0.31 (ton) 167.39 192.82 8/21 13:15:00 83.25 0.01
1_BDRM_3_2 Heating 1.04 (kBtu/h) 1.3 (kBtu/h) 27.55 36.02 1/21 08:45:00 44.42 0.01
1_BDRM_3_3 Cooling 0.49 (ton) 0.56 (ton) 298.76 343.26 8/21 13:15:00 83.25 0.01
1_BDRM_3_3 Heating 1.82 (kBtu/h) 2.28 (kBtu/h) 48.73 69.92 1/21 24:00:00 44.42 0.01
1_BDRM_3_4 Cooling 0.28 (ton) 0.32 (ton) 171.63 197.06 8/21 13:30:00 83.39 0.01
1_BDRM_3_4 Heating 1.41 (kBtu/h) 1.77 (kBtu/h) 38.14 46.62 1/21 24:00:00 44.42 0.01
1_BDRM_4_2 Cooling 0.26 (ton) 0.3 (ton) 161.03 184.34 8/21 15:00:00 83.66 0.01
1_BDRM_4_2 Heating 1.43 (kBtu/h) 1.79 (kBtu/h) 38.14 48.73 1/21 09:15:00 44.42 0.01
1_BDRM_4_3 Cooling 0.47 (ton) 0.54 (ton) 290.29 332.66 8/21 15:15:00 83.5 0.01
1_BDRM_4_3 Heating 2.34 (kBtu/h) 2.93 (kBtu/h) 63.57 86.87 1/21 24:00:00 44.42 0.01
1_BDRM_4_4 Cooling 0.28 (ton) 0.32 (ton) 171.63 197.06 8/21 15:15:00 83.5 0.01
1_BDRM_4_4 Heating 1.77 (kBtu/h) 2.22 (kBtu/h) 46.62 59.33 1/21 24:00:00 44.42 0.01
1_BDRM_5_2 Cooling 0.27 (ton) 0.31 (ton) 163.15 188.58 8/21 14:30:00 83.66 0.01
1_BDRM_5_2 Heating 1.37 (kBtu/h) 1.71 (kBtu/h) 36.02 46.62 1/21 08:30:00 44.42 0.01
1_BDRM_5_3 Cooling 0.47 (ton) 0.54 (ton) 288.17 330.55 8/21 15:00:00 83.66 0.01
1_BDRM_5_3 Heating 2.29 (kBtu/h) 2.86 (kBtu/h) 61.45 86.87 1/21 24:00:00 44.42 0.01
1_BDRM_5_4 Cooling 0.27 (ton) 0.31 (ton) 167.39 192.82 8/21 15:00:00 83.66 0.01
1_BDRM_5_4 Heating 1.77 (kBtu/h) 2.21 (kBtu/h) 46.62 59.33 1/21 24:00:00 44.42 0.01
1_BDRM_6_2 Cooling 0.24 (ton) 0.28 (ton) 148.32 169.51 8/21 15:00:00 83.66 0.01
1_BDRM_6_2 Heating 0.99 (kBtu/h) 1.23 (kBtu/h) 25.43 36.02 1/21 09:15:00 44.42 0.01
1_BDRM_6_3 Cooling 0.42 (ton) 0.49 (ton) 260.62 300.88 8/21 15:00:00 83.66 0.01
1_BDRM_6_3 Heating 1.83 (kBtu/h) 2.29 (kBtu/h) 48.73 69.92 1/21 24:00:00 44.42 0.01
1_BDRM_6_4 Cooling 0.24 (ton) 0.28 (ton) 148.32 171.63 8/21 15:00:00 83.66 0.01
1_BDRM_6_4 Heating 1.42 (kBtu/h) 1.77 (kBtu/h) 38.14 46.62 1/21 24:00:00 44.42 0.01
1_BDRM_7_2 Cooling 0.3 (ton) 0.35 (ton) 186.46 214.01 8/21 13:00:00 83.12 0.01
1_BDRM_7_2 Heating 1.37 (kBtu/h) 1.71 (kBtu/h) 36.02 46.62 1/21 08:30:00 44.42 0.01
1_BDRM_7_3 Cooling 0.54 (ton) 0.62 (ton) 334.78 383.52 8/21 13:15:00 83.25 0.01
1_BDRM_7_3 Heating 2.27 (kBtu/h) 2.83 (kBtu/h) 61.45 86.87 1/21 24:00:00 44.42 0.01
1_BDRM_7_4 Cooling 0.32 (ton) 0.36 (ton) 194.94 224.6 8/21 13:30:00 83.39 0.01
1_BDRM_7_4 Heating 1.75 (kBtu/h) 2.19 (kBtu/h) 46.62 59.33 1/21 24:00:00 44.42 0.01
2_BDRM_1_2 Cooling 0.53 (ton) 0.61 (ton) 326.31 377.16 8/21 09:45:00 79.09 0.01
2_BDRM_1_2 Heating 3.11 (kBtu/h) 3.89 (kBtu/h) 82.64 103.83 1/21 08:30:00 44.42 0.01
2_BDRM_1_3 Cooling 0.98 (ton) 1.13 (ton) 603.88 694.99 8/21 10:00:00 79.56 0.01
2_BDRM_1_3 Heating 5.4 (kBtu/h) 6.76 (kBtu/h) 146.2 182.22 1/21 24:00:00 44.42 0.01
2_BDRM_1_4 Cooling 0.63 (ton) 0.72 (ton) 385.64 444.96 8/21 13:00:00 83.12 0.01
2_BDRM_1_4 Heating 3.72 (kBtu/h) 4.65 (kBtu/h) 99.59 125.01 1/21 24:00:00 44.42 0.01
2_BDRM_2_2 Cooling 0.62 (ton) 0.71 (ton) 379.28 436.49 8/21 16:30:00 82.58 0.01
2_BDRM_2_2 Heating 3.36 (kBtu/h) 4.2 (kBtu/h) 91.11 112.3 1/21 08:30:00 44.42 0.01
2_BDRM_2_3 Cooling 1.17 (ton) 1.35 (ton) 722.54 830.6 8/21 16:45:00 82.36 0.01
2_BDRM_2_3 Heating 5.83 (kBtu/h) 7.28 (kBtu/h) 156.8 194.94 1/21 24:00:00 44.42 0.01
2_BDRM_2_4 Cooling 0.74 (ton) 0.85 (ton) 453.44 521.24 8/21 16:30:00 82.58 0.01
2_BDRM_2_4 Heating 3.96 (kBtu/h) 4.95 (kBtu/h) 105.94 133.49 1/21 24:00:00 44.42 0.01
2_BDRM_3_2 Cooling 0.52 (ton) 0.6 (ton) 319.95 366.57 8/21 09:30:00 78.64 0.01
2_BDRM_3_2 Heating 2.47 (kBtu/h) 3.09 (kBtu/h) 65.69 82.64 1/21 08:00:00 44.42 0.01
2_BDRM_3_3 Cooling 1.03 (ton) 1.19 (ton) 635.66 731.01 8/21 09:30:00 78.64 0.01
2_BDRM_3_3 Heating 5.56 (kBtu/h) 6.95 (kBtu/h) 148.32 186.46 1/21 24:00:00 44.42 0.01
2_BDRM_3_4 Cooling 0.59 (ton) 0.68 (ton) 364.45 417.42 8/21 10:00:00 79.56 0.01
2_BDRM_3_4 Heating 3.9 (kBtu/h) 4.87 (kBtu/h) 103.83 131.37 1/21 24:00:00 44.42 0.01
3_BDRM_1_3 Cooling 1.32 (ton) 1.52 (ton) 813.65 936.54 8/21 16:30:00 82.58 0.01
3_BDRM_1_3 Heating 6.49 (kBtu/h) 8.11 (kBtu/h) 173.75 218.24 1/21 24:00:00 44.42 0.01
3_BDRM_1_4 Cooling 0.78 (ton) 0.9 (ton) 480.99 553.03 8/21 16:15:00 82.8 0.01
3_BDRM_1_4 Heating 4.55 (kBtu/h) 5.69 (kBtu/h) 122.9 152.56 1/21 24:00:00 44.42 0.01
3_BDRM_2_2 Cooling 0.77 (ton) 0.88 (ton) 472.51 542.43 8/21 16:30:00 82.58 0.01
3_BDRM_2_2 Heating 3.73 (kBtu/h) 4.66 (kBtu/h) 99.59 125.01 1/21 07:45:00 44.42 0.01
BATHRM_1 Cooling 0.06 (ton) 0.07 (ton) 40.26 46.62 8/21 14:15:00 83.66 0.01
BATHRM_1 Heating 0.27 (kBtu/h) 0.34 (kBtu/h) 6.36 8.48 1/21 07:30:00 44.42 0.01
BATHRM_2 Cooling 0.07 (ton) 0.08 (ton) 42.38 48.73 8/21 14:15:00 83.66 0.01
BATHRM_2 Heating 0.3 (kBtu/h) 0.37 (kBtu/h) 8.48 10.59 1/21 07:15:00 44.42 0.01
COFFEE_SHOP Cooling 2.75 (ton) 3.16 (ton) 1690.87 1945.13 8/21 16:15:00 82.8 0.01
COFFEE_SHOP Heating 14.53 (kBtu/h) 18.17 (kBtu/h) 375.04 1057.32 1/21 07:00:00 44.42 0.01
COMMUNITY_RM Cooling 1.72 (ton) 1.97 (ton) 1055.2 1212.0 8/21 15:00:00 83.66 0.01
COMMUNITY_RM Heating 5.6 (kBtu/h) 7.0 (kBtu/h) 150.44 464.03 1/21 07:00:00 44.42 0.01
GYM 1 Cooling 1.09 (ton) 1.25 (ton) 669.57 771.27 8/21 09:00:00 77.72 0.01
GYM 1 Heating 5.39 (kBtu/h) 6.74 (kBtu/h) 144.08 480.99 1/21 06:00:00 44.42 0.01
LOBBY_ENTRY Cooling 0.0 (ton) 0.0 (ton) 0.0 139.85 83.66 0.01
LOBBY_ENTRY Heating 2.23 (kBtu/h) 2.79 (kBtu/h) 59.33 139.85 1/21 08:00:00 44.42 0.01
LT_RETAIL_1 Cooling 0.86 (ton) 0.99 (ton) 497.94 572.1 8/21 08:00:00 75.67 0.01
LT_RETAIL_1 Heating 7.81 (kBtu/h) 9.76 (kBtu/h) 201.29 313.59 1/21 08:00:00 44.42 0.01
LT_RETAIL_2 Cooling 0.89 (ton) 1.02 (ton) 521.24 599.64 8/21 08:00:00 75.67 0.01
LT_RETAIL_2 Heating 8.23 (kBtu/h) 10.29 (kBtu/h) 211.89 264.86 1/21 08:00:00 44.42 0.01
LT_RETAIL_3 Cooling 0.67 (ton) 0.78 (ton) 389.87 447.08 8/21 08:00:00 75.67 0.01
LT_RETAIL_3 Heating 6.08 (kBtu/h) 7.59 (kBtu/h) 156.8 243.67 1/21 08:00:00 44.42 0.01
LT_RETAIL_4 Cooling 0.86 (ton) 0.99 (ton) 527.6 606.0 8/21 16:30:00 82.58 0.01
LT_RETAIL_4 Heating 8.28 (kBtu/h) 10.36 (kBtu/h) 214.01 266.98 1/21 08:00:00 44.42 0.01
OFFICE 1 Cooling 0.27 (ton) 0.31 (ton) 167.39 192.82 8/21 13:00:00 83.12 0.01
OFFICE 1 Heating 1.91 (kBtu/h) 2.39 (kBtu/h) 48.73 63.57 1/21 09:00:00 44.42 0.01
GARBAGE 1 Cooling 0.0 (ton) 0.0 (ton) 0.0 52.97 83.66 0.01
GARBAGE 1 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 52.97 44.42 0.01
MAIL_SHIPPING Cooling 0.0 (ton) 0.0 (ton) 0.0 52.97 83.66 0.01
MAIL_SHIPPING Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 52.97 44.42 0.01
STAIRWELL_1_2 Cooling 0.0 (ton) 0.0 (ton) 0.0 16.95 83.66 0.01
STAIRWELL_1_2 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 16.95 44.42 0.01
STAIRWELL_1_3 Cooling 0.0 (ton) 0.0 (ton) 0.0 36.02 83.66 0.01
STAIRWELL_1_3 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 36.02 44.42 0.01
STAIRWELL_1_4 Cooling 0.0 (ton) 0.0 (ton) 0.0 16.95 83.66 0.01
STAIRWELL_1_4 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 16.95 44.42 0.01
STAIRWELL_2_2 Cooling 0.0 (ton) 0.0 (ton) 0.0 16.95 83.66 0.01
STAIRWELL_2_2 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 16.95 44.42 0.01
STAIRWELL_2_3 Cooling 0.0 (ton) 0.0 (ton) 0.0 36.02 83.66 0.01
STAIRWELL_2_3 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 36.02 44.42 0.01
STAIRWELL_2_4 Cooling 0.0 (ton) 0.0 (ton) 0.0 16.95 83.66 0.01
STAIRWELL_2_4 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 16.95 44.42 0.01
STAIR_1 Cooling 0.0 (ton) 0.0 (ton) 0.0 16.95 83.66 0.01
STAIR_1 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 16.95 44.42 0.01
STAIR_2 Cooling 0.0 (ton) 0.0 (ton) 0.0 16.95 83.66 0.01
STAIR_2 Heating 0.0 (kBtu/h) 0.0 (kBtu/h) 0.0 16.95 44.42 0.01

Zone Equipment Detail


Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Object Description Value Sizing Count
ZoneHVAC:IdealLoadsAirSystem Sensible Heat Recovery Effectiveness 70.0 %
Latent Heat Recovery Effectiveness 65.0 %

Air Loops Detail

No Data to Show for Air Loops Detail

Plant Loops Detail


Object Description Value Sizing Count
(supply)
Pump:VariableSpeed Water Flow Rate 916.92 gal/min Autosized
Rated Pump Head 0.0 ft H2O
Motor Efficiency 90.0 %
WaterHeater:Mixed Heating Capacity 0.0 Btu/hr Hard Sized
Heater Thermal Efficiency 100.0 %
Use Side Effectiveness 100.0 %
Source Side Effectiveness 100.0 %
WaterHeater:Mixed Heating Capacity 3,412,141.6 Btu/hr Hard Sized
Heater Thermal Efficiency 100.0 %
Use Side Effectiveness 100.0 %
Source Side Effectiveness 100.0 %
SetpointManager:Scheduled Control Variable - Temperature can't inspect schedule
(demand)
WaterUse:Connections SHW Loop Water Use Connection
(controls)
Loop Flow Rate Range Minimum Loop Flow Rate 0.00 gal/min Hard Sized
Loop Flow Rate Range Maximum Loop Flow Rate 916.92 gal/min Autosized
Loop Temperature Range 50.0 to 212.0 F
Loop Design Exit Temperature 140.0 F
Loop Design Temperature Difference 72.0 R
Equipment Loading/Staging Optimal

Object Description Value Sizing Count
(supply)
Pump:VariableSpeed Water Flow Rate 32.83 gal/min Autosized
Rated Pump Head 20.0 ft H2O
Motor Efficiency 90.0 %
HeatPump:WaterToWater:EquationFit:Heating Heating Capacity 1,364,856.7 Btu/hr Hard Sized
Water Flow Rate 32.83 gal/min Autosized
SetpointManager:Scheduled Control Variable - Temperature can't inspect schedule
(demand)
Pipe:Indoor Service Preheat Water Loop Pipe 314.95097567963927ft
WaterHeater:Mixed Plant Loop Service Hot Water Loop
(controls)
Loop Flow Rate Range Minimum Loop Flow Rate 0.00 gal/min Hard Sized
Loop Flow Rate Range Maximum Loop Flow Rate 32.83 gal/min Autosized
Loop Temperature Range 32.0 to 212.0 F
Loop Design Exit Temperature 140.0 F
Loop Design Temperature Difference 18.0 R
Equipment Loading/Staging Optimal

Object Description Value Sizing Count
(supply)
Pump:VariableSpeed Water Flow Rate 54.88 gal/min Autosized
Rated Pump Head 20.0 ft H2O
Motor Efficiency 90.0 %
WaterHeater:Mixed Heating Capacity 0.0 Btu/hr Hard Sized
Heater Thermal Efficiency 100.0 %
Use Side Effectiveness 100.0 %
Source Side Effectiveness 100.0 %
SetpointManager:Scheduled Control Variable - Temperature can't inspect schedule
(demand)
HeatPump:WaterToWater:EquationFit:Heating Plant Loop Service Preheat Water Loop
(controls)
Loop Flow Rate Range Minimum Loop Flow Rate 0.00 gal/min Hard Sized
Loop Flow Rate Range Maximum Loop Flow Rate 54.88 gal/min Autosized
Loop Temperature Range 32.0 to 212.0 F
Loop Design Exit Temperature 86.0 F
Loop Design Temperature Difference 18.0 R
Equipment Loading/Staging Optimal

Object Description Value Sizing Count
(supply)
Pump:VariableSpeed Water Flow Rate 46.61 gal/min Autosized
Rated Pump Head 0.0 ft H2O
Motor Efficiency 90.0 %
PlantComponent:TemperatureSource Water Flow Rate 46.61 gal/min Autosized
SetpointManager:Scheduled Control Variable - Temperature can't inspect schedule
(demand)
WaterHeater:Mixed Plant Loop Waste Water Heat Pump Loop
(controls)
Loop Flow Rate Range Minimum Loop Flow Rate 0.00 gal/min Hard Sized
Loop Flow Rate Range Maximum Loop Flow Rate 46.61 gal/min Autosized
Loop Temperature Range 50.0 to 212.0 F
Loop Design Exit Temperature 140.0 F
Loop Design Temperature Difference 27.0 R
Equipment Loading/Staging SequentialLoad

Outdoor Air


Average Number of Occupants Nominal Number of Occupants Zone Volume (ft^3) Avg. Mechanical Ventilation (ach) Min. Mechanical Ventilation (ach) Avg. Infiltration (ach) Min. Infiltration (ach) Avg. Simple Ventilation (ach) Min. Simple Ventilation (ach)
0_BDRM_1_2 0.44 0.63 4500 0.359 0.35 0.032 0.0 0.0 0.0
0_BDRM_1_3 0.44 0.63 4500 0.359 0.351 0.037 0.0 0.0 0.0
0_BDRM_1_4 0.44 0.63 4500 0.359 0.349 0.041 0.0 0.0 0.0
0_BDRM_2_2 0.44 0.63 4500 0.358 0.349 0.032 0.0 0.0 0.0
0_BDRM_2_3 0.44 0.63 4500 0.359 0.35 0.037 0.0 0.0 0.0
0_BDRM_2_4 0.44 0.63 4500 0.359 0.349 0.041 0.0 0.0 0.0
0_BDRM_3_2 0.44 0.63 4500 0.358 0.349 0.032 0.0 0.0 0.0
0_BDRM_3_3 0.44 0.63 4500 0.359 0.351 0.037 0.0 0.0 0.0
0_BDRM_3_4 0.44 0.63 4500 0.359 0.349 0.041 0.0 0.0 0.0
0_BDRM_4_2 0.44 0.63 4500 0.358 0.349 0.032 0.0 0.0 0.0
0_BDRM_4_3 0.44 0.63 4500 0.359 0.351 0.037 0.0 0.0 0.0
0_BDRM_4_4 0.44 0.63 4500 0.359 0.349 0.041 0.0 0.0 0.0
1_BDRM_1_2 1.08 1.55 6000 0.359 0.349 0.032 0.0 0.0 0.0
1_BDRM_1_3 1.08 1.55 6000 0.359 0.351 0.037 0.0 0.0 0.0
1_BDRM_1_4 1.08 1.55 6000 0.359 0.349 0.041 0.0 0.0 0.0
1_BDRM_2_2 1.08 1.55 6000 0.359 0.35 0.032 0.0 0.0 0.0
1_BDRM_2_3 1.08 1.55 6000 0.359 0.351 0.037 0.0 0.0 0.0
1_BDRM_2_4 1.08 1.55 6000 0.359 0.349 0.041 0.0 0.0 0.0
1_BDRM_3_2 1.08 1.55 6000 0.359 0.349 0.032 0.0 0.0 0.0
1_BDRM_3_3 1.08 1.55 6000 0.359 0.351 0.037 0.0 0.0 0.0
1_BDRM_3_4 1.08 1.55 6000 0.359 0.349 0.041 0.0 0.0 0.0
1_BDRM_4_2 1.08 1.55 7500 0.358 0.348 0.032 0.0 0.0 0.0
1_BDRM_4_3 1.08 1.55 7500 0.359 0.35 0.037 0.0 0.0 0.0
1_BDRM_4_4 1.08 1.55 7500 0.359 0.349 0.041 0.0 0.0 0.0
1_BDRM_5_2 1.08 1.55 7500 0.358 0.349 0.032 0.0 0.0 0.0
1_BDRM_5_3 1.08 1.55 7500 0.359 0.35 0.037 0.0 0.0 0.0
1_BDRM_5_4 1.08 1.55 7500 0.359 0.349 0.041 0.0 0.0 0.0
1_BDRM_6_2 1.08 1.55 6000 0.359 0.349 0.032 0.0 0.0 0.0
1_BDRM_6_3 1.08 1.55 6000 0.359 0.351 0.037 0.0 0.0 0.0
1_BDRM_6_4 1.08 1.55 6000 0.359 0.349 0.041 0.0 0.0 0.0
1_BDRM_7_2 1.08 1.55 7500 0.359 0.349 0.032 0.0 0.0 0.0
1_BDRM_7_3 1.08 1.55 7500 0.359 0.351 0.037 0.0 0.0 0.0
1_BDRM_7_4 1.08 1.55 7500 0.359 0.35 0.041 0.0 0.0 0.0
2_BDRM_1_2 1.72 2.47 11000 0.358 0.349 0.062 0.0 0.0 0.0
2_BDRM_1_3 1.72 2.47 11000 0.359 0.349 0.071 0.0 0.0 0.0
2_BDRM_1_4 1.72 2.47 11000 0.358 0.349 0.078 0.0 0.0 0.0
2_BDRM_2_2 1.72 2.47 12000 0.358 0.348 0.06 0.0 0.0 0.0
2_BDRM_2_3 1.72 2.47 12000 0.359 0.349 0.07 0.0 0.0 0.0
2_BDRM_2_4 1.72 2.47 12000 0.358 0.348 0.077 0.0 0.0 0.0
2_BDRM_3_2 1.72 2.47 11500 0.358 0.348 0.059 0.0 0.0 0.0
2_BDRM_3_3 1.72 2.47 11500 0.359 0.349 0.068 0.0 0.0 0.0
2_BDRM_3_4 1.72 2.47 11500 0.358 0.348 0.075 0.0 0.0 0.0
3_BDRM_1_3 2.36 3.39 15000 0.359 0.349 0.059 0.0 0.0 0.0
3_BDRM_1_4 2.36 3.39 15000 0.358 0.349 0.066 0.0 0.0 0.0
3_BDRM_2_2 2.36 3.39 15000 0.358 0.349 0.052 0.0 0.0 0.0
BATHRM_1 0.12 0.43 2100 0.262 0.256 0.0 0.0 0.0 0.0
BATHRM_2 0.12 0.43 2100 0.262 0.255 0.0 0.0 0.0 0.0
COFFEE_SHOP 45.4 105.0 21000 3.083 2.963 0.04 0.0 0.0 0.0
COMMUNITY_RM 21.4 75.0 21000 1.357 1.318 0.029 0.0 0.0 0.0
GYM 1 18.97 20.94 14700 2.01 1.952 0.049 0.0 0.0 0.0
LOBBY_ENTRY 4.62 9.0 8400 1.02 0.988 0.044 0.0 0.0 0.0
LT_RETAIL_1 10.4 20.25 18900 1.018 0.988 0.029 0.0 0.0 0.0
LT_RETAIL_2 8.48 16.5 15400 1.018 0.988 0.056 0.0 0.0 0.0
LT_RETAIL_3 8.09 15.75 14700 1.017 0.988 0.029 0.0 0.0 0.0
LT_RETAIL_4 8.48 16.5 15400 1.017 0.988 0.055 0.0 0.0 0.0
OFFICE 1 1.49 1.58 10500 0.372 0.362 0.031 0.0 0.0 0.0

Cash Flow

No Data to Show for Cash Flow

Site and Source Summary


Total Energy (kBtu) Energy Per Total Building Area (kBtu/ft^2) Energy Per Conditioned Building Area (kBtu/ft^2)
Total Site Energy 1505124.1 23.2 23.5
Net Site Energy 441256.2 6.8 6.9
Total Source Energy 3803485.7 58.5 59.4
Net Source Energy 434223.5 6.7 6.8

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613

Schedule Overview


Schedule Type Limits Rules Use Count
Air Velocity Schedule Velocity 0 7
Always On Dimensionless 0 18
Ambient Temp Schedule Temperature 0 2
ApartmentMidRise Activity Schedule ActivityLevel 0 1
ApartmentMidRise All Off Dimensionless 0 4
ApartmentMidRise BLDG_ELEVATORS Dimensionless 0 4
ApartmentMidRise CLGSETP_OFF_SCH_NO_OPTIMUM Temperature 1 1
ApartmentMidRise EQP_OFF_SCH_2010_2013 Dimensionless 1 1
ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM Temperature 1 1
ApartmentMidRise INF_COR_SCH Dimensionless 0 4
ApartmentMidRise INF_OFF_SCH Dimensionless 0 1
ApartmentMidRise LTG_COR_SCH_2013 Dimensionless 0 4
ApartmentMidRise LTG_OFF_SCH_2010_2013 Dimensionless 1 1
ApartmentMidRise OCC_OFF_SCH Dimensionless 1 1
Clothing Schedule ClothingInsulation 1 7
Elevator Schedule 2 1
Elevator Schedule 1 Dimensionless 2 3
Elevator Schedule 2 Dimensionless 2 3
Elevator Schedule 3 Dimensionless 2 3
HotelSmall Activity_Sch ActivityLevel 0 14
HotelSmall AlwaysOff Dimensionless 0 18
HotelSmall BLDG_ELEVATORS Dimensionless 0 8
HotelSmall BLDG_LIGHT_EXERCENTER_SCH Dimensionless 0 1
HotelSmall BLDG_LIGHT_MEETINGROOM_SCH Dimensionless 0 1
HotelSmall BLDG_LIGHT_RESTROOM_SCH Dimensionless 0 2
HotelSmall BLDG_LIGHT_STAIR_SCH Dimensionless 0 8
HotelSmall BLDG_LIGHT_STORAGE_SCH Dimensionless 1 2
HotelSmall CommonArea_ClgSP_Sch Temperature 0 4
HotelSmall CommonArea_HtgSP_Sch Temperature 0 4
HotelSmall CommonArea_Infil_Sch Dimensionless 0 4
HotelSmall ExerciseCenter_Eqp_Sch Dimensionless 0 1
HotelSmall ExerciseCenter_Occ_Sch Dimensionless 0 1
HotelSmall Lobby_Eqp_Sch Dimensionless 0 2
HotelSmall Lobby_Occ_Sch Dimensionless 1 2
HotelSmall MeetingRoom_Eqp_Sch Dimensionless 0 1
HotelSmall MeetingRoom_Occ_Sch Dimensionless 1 1
HotelSmall SemiHeated_HtgSP_Sch Temperature 0 10
PV Shading Transmittance Schedule Dimensionless 0 20
res bath schedule Dimensionless 7 3
res bath schedule 1 Dimensionless 7 3
res bath schedule 10 Dimensionless 7 3
res bath schedule 11 Dimensionless 7 3
res bath schedule 12 Dimensionless 7 3
res bath schedule 13 Dimensionless 7 3
res bath schedule 14 Dimensionless 7 3
res bath schedule 15 Dimensionless 7 3
res bath schedule 16 Dimensionless 7 3
res bath schedule 17 Dimensionless 7 3
res bath schedule 18 Dimensionless 7 3
res bath schedule 19 Dimensionless 7 3
res bath schedule 2 Dimensionless 7 3
res bath schedule 20 Dimensionless 7 3
res bath schedule 21 Dimensionless 7 3
res bath schedule 22 Dimensionless 7 3
res bath schedule 23 Dimensionless 7 3
res bath schedule 24 Dimensionless 7 3
res bath schedule 25 Dimensionless 7 3
res bath schedule 26 Dimensionless 7 3
res bath schedule 27 Dimensionless 7 3
res bath schedule 28 Dimensionless 7 3
res bath schedule 29 Dimensionless 7 3
res bath schedule 3 Dimensionless 7 3
res bath schedule 30 Dimensionless 7 3
res bath schedule 31 Dimensionless 7 3
res bath schedule 32 Dimensionless 7 3
res bath schedule 33 Dimensionless 7 3
res bath schedule 34 Dimensionless 7 3
res bath schedule 35 Dimensionless 7 3
res bath schedule 36 Dimensionless 7 3
res bath schedule 37 Dimensionless 7 3
res bath schedule 38 Dimensionless 7 3
res bath schedule 39 Dimensionless 7 3
res bath schedule 4 Dimensionless 7 3
res bath schedule 40 Dimensionless 7 3
res bath schedule 41 Dimensionless 7 3
res bath schedule 42 Dimensionless 7 3
res bath schedule 43 Dimensionless 7 3
res bath schedule 44 Dimensionless 7 3
res bath schedule 5 Dimensionless 7 3
res bath schedule 6 Dimensionless 7 3
res bath schedule 7 Dimensionless 7 3
res bath schedule 8 Dimensionless 7 3
res bath schedule 9 Dimensionless 7 3
res cd electric|Building Unit 001 schedule Dimensionless 7 45
res cooling setpoint Temperature 12 45
res cw schedule Dimensionless 7 2
res cw schedule 1 Dimensionless 7 2
res cw schedule 10 Dimensionless 7 2
res cw schedule 11 Dimensionless 7 2
res cw schedule 12 Dimensionless 7 2
res cw schedule 13 Dimensionless 7 2
res cw schedule 14 Dimensionless 7 2
res cw schedule 15 Dimensionless 7 2
res cw schedule 16 Dimensionless 7 2
res cw schedule 17 Dimensionless 7 2
res cw schedule 18 Dimensionless 7 2
res cw schedule 19 Dimensionless 7 2
res cw schedule 2 Dimensionless 7 2
res cw schedule 20 Dimensionless 7 2
res cw schedule 21 Dimensionless 7 2
res cw schedule 22 Dimensionless 7 2
res cw schedule 23 Dimensionless 7 2
res cw schedule 24 Dimensionless 7 2
res cw schedule 25 Dimensionless 7 2
res cw schedule 26 Dimensionless 7 2
res cw schedule 27 Dimensionless 7 2
res cw schedule 28 Dimensionless 7 2
res cw schedule 29 Dimensionless 7 2
res cw schedule 3 Dimensionless 7 2
res cw schedule 30 Dimensionless 7 2
res cw schedule 31 Dimensionless 7 2
res cw schedule 32 Dimensionless 7 2
res cw schedule 33 Dimensionless 7 2
res cw schedule 34 Dimensionless 7 2
res cw schedule 35 Dimensionless 7 2
res cw schedule 36 Dimensionless 7 2
res cw schedule 37 Dimensionless 7 2
res cw schedule 38 Dimensionless 7 2
res cw schedule 39 Dimensionless 7 2
res cw schedule 4 Dimensionless 7 2
res cw schedule 40 Dimensionless 7 2
res cw schedule 41 Dimensionless 7 2
res cw schedule 42 Dimensionless 7 2
res cw schedule 43 Dimensionless 7 2
res cw schedule 44 Dimensionless 7 2
res cw schedule 5 Dimensionless 7 2
res cw schedule 6 Dimensionless 7 2
res cw schedule 7 Dimensionless 7 2
res cw schedule 8 Dimensionless 7 2
res cw schedule 9 Dimensionless 7 2
res dw schedule Dimensionless 7 2
res dw schedule 1 Dimensionless 7 2
res dw schedule 10 Dimensionless 7 2
res dw schedule 11 Dimensionless 7 2
res dw schedule 12 Dimensionless 7 2
res dw schedule 13 Dimensionless 7 2
res dw schedule 14 Dimensionless 7 2
res dw schedule 15 Dimensionless 7 2
res dw schedule 16 Dimensionless 7 2
res dw schedule 17 Dimensionless 7 2
res dw schedule 18 Dimensionless 7 2
res dw schedule 19 Dimensionless 7 2
res dw schedule 2 Dimensionless 7 2
res dw schedule 20 Dimensionless 7 2
res dw schedule 21 Dimensionless 7 2
res dw schedule 22 Dimensionless 7 2
res dw schedule 23 Dimensionless 7 2
res dw schedule 24 Dimensionless 7 2
res dw schedule 25 Dimensionless 7 2
res dw schedule 26 Dimensionless 7 2
res dw schedule 27 Dimensionless 7 2
res dw schedule 28 Dimensionless 7 2
res dw schedule 29 Dimensionless 7 2
res dw schedule 3 Dimensionless 7 2
res dw schedule 30 Dimensionless 7 2
res dw schedule 31 Dimensionless 7 2
res dw schedule 32 Dimensionless 7 2
res dw schedule 33 Dimensionless 7 2
res dw schedule 34 Dimensionless 7 2
res dw schedule 35 Dimensionless 7 2
res dw schedule 36 Dimensionless 7 2
res dw schedule 37 Dimensionless 7 2
res dw schedule 38 Dimensionless 7 2
res dw schedule 39 Dimensionless 7 2
res dw schedule 4 Dimensionless 7 2
res dw schedule 40 Dimensionless 7 2
res dw schedule 41 Dimensionless 7 2
res dw schedule 42 Dimensionless 7 2
res dw schedule 43 Dimensionless 7 2
res dw schedule 44 Dimensionless 7 2
res dw schedule 5 Dimensionless 7 2
res dw schedule 6 Dimensionless 7 2
res dw schedule 7 Dimensionless 7 2
res dw schedule 8 Dimensionless 7 2
res dw schedule 9 Dimensionless 7 2
res heating setpoint Temperature 12 45
res hot water distribution|Building Unit 001 schedule Dimensionless 12 1
res hot water distribution|Building Unit 002 schedule Dimensionless 12 1
res hot water distribution|Building Unit 003 schedule Dimensionless 12 1
res hot water distribution|Building Unit 004 schedule Dimensionless 12 1
res hot water distribution|Building Unit 005 schedule Dimensionless 12 1
res hot water distribution|Building Unit 006 schedule Dimensionless 12 1
res hot water distribution|Building Unit 007 schedule Dimensionless 12 1
res hot water distribution|Building Unit 008 schedule Dimensionless 12 1
res hot water distribution|Building Unit 009 schedule Dimensionless 12 1
res hot water distribution|Building Unit 010 schedule Dimensionless 12 1
res hot water distribution|Building Unit 011 schedule Dimensionless 12 1
res hot water distribution|Building Unit 012 schedule Dimensionless 12 1
res hot water distribution|Building Unit 101 schedule Dimensionless 12 1
res hot water distribution|Building Unit 102 schedule Dimensionless 12 1
res hot water distribution|Building Unit 103 schedule Dimensionless 12 1
res hot water distribution|Building Unit 104 schedule Dimensionless 12 1
res hot water distribution|Building Unit 105 schedule Dimensionless 12 1
res hot water distribution|Building Unit 106 schedule Dimensionless 12 1
res hot water distribution|Building Unit 107 schedule Dimensionless 12 1
res hot water distribution|Building Unit 108 schedule Dimensionless 12 1
res hot water distribution|Building Unit 109 schedule Dimensionless 12 1
res hot water distribution|Building Unit 110 schedule Dimensionless 12 1
res hot water distribution|Building Unit 111 schedule Dimensionless 12 1
res hot water distribution|Building Unit 112 schedule Dimensionless 12 1
res hot water distribution|Building Unit 113 schedule Dimensionless 12 1
res hot water distribution|Building Unit 114 schedule Dimensionless 12 1
res hot water distribution|Building Unit 115 schedule Dimensionless 12 1
res hot water distribution|Building Unit 116 schedule Dimensionless 12 1
res hot water distribution|Building Unit 117 schedule Dimensionless 12 1
res hot water distribution|Building Unit 118 schedule Dimensionless 12 1
res hot water distribution|Building Unit 119 schedule Dimensionless 12 1
res hot water distribution|Building Unit 120 schedule Dimensionless 12 1
res hot water distribution|Building Unit 121 schedule Dimensionless 12 1
res hot water distribution|Building Unit 201 schedule Dimensionless 12 1
res hot water distribution|Building Unit 202 schedule Dimensionless 12 1
res hot water distribution|Building Unit 203 schedule Dimensionless 12 1
res hot water distribution|Building Unit 204 schedule Dimensionless 12 1
res hot water distribution|Building Unit 205 schedule Dimensionless 12 1
res hot water distribution|Building Unit 206 schedule Dimensionless 12 1
res hot water distribution|Building Unit 207 schedule Dimensionless 12 1
res hot water distribution|Building Unit 208 schedule Dimensionless 12 1
res hot water distribution|Building Unit 209 schedule Dimensionless 12 1
res hot water distribution|Building Unit 301 schedule Dimensionless 12 1
res hot water distribution|Building Unit 302 schedule Dimensionless 12 1
res hot water distribution|Building Unit 303 schedule Dimensionless 12 1
res lighting interior Dimensionless 12 45
res misc plug loads schedule Dimensionless 12 45
res occupants schedule Dimensionless 12 45
res range electric|false schedule Dimensionless 12 45
res refrig schedule Dimensionless 12 45
res shower schedule Dimensionless 7 3
res shower schedule 1 Dimensionless 7 3
res shower schedule 10 Dimensionless 7 3
res shower schedule 11 Dimensionless 7 3
res shower schedule 12 Dimensionless 7 3
res shower schedule 13 Dimensionless 7 3
res shower schedule 14 Dimensionless 7 3
res shower schedule 15 Dimensionless 7 3
res shower schedule 16 Dimensionless 7 3
res shower schedule 17 Dimensionless 7 3
res shower schedule 18 Dimensionless 7 3
res shower schedule 19 Dimensionless 7 3
res shower schedule 2 Dimensionless 7 3
res shower schedule 20 Dimensionless 7 3
res shower schedule 21 Dimensionless 7 3
res shower schedule 22 Dimensionless 7 3
res shower schedule 23 Dimensionless 7 3
res shower schedule 24 Dimensionless 7 3
res shower schedule 25 Dimensionless 7 3
res shower schedule 26 Dimensionless 7 3
res shower schedule 27 Dimensionless 7 3
res shower schedule 28 Dimensionless 7 3
res shower schedule 29 Dimensionless 7 3
res shower schedule 3 Dimensionless 7 3
res shower schedule 30 Dimensionless 7 3
res shower schedule 31 Dimensionless 7 3
res shower schedule 32 Dimensionless 7 3
res shower schedule 33 Dimensionless 7 3
res shower schedule 34 Dimensionless 7 3
res shower schedule 35 Dimensionless 7 3
res shower schedule 36 Dimensionless 7 3
res shower schedule 37 Dimensionless 7 3
res shower schedule 38 Dimensionless 7 3
res shower schedule 39 Dimensionless 7 3
res shower schedule 4 Dimensionless 7 3
res shower schedule 40 Dimensionless 7 3
res shower schedule 41 Dimensionless 7 3
res shower schedule 42 Dimensionless 7 3
res shower schedule 43 Dimensionless 7 3
res shower schedule 44 Dimensionless 7 3
res shower schedule 5 Dimensionless 7 3
res shower schedule 6 Dimensionless 7 3
res shower schedule 7 Dimensionless 7 3
res shower schedule 8 Dimensionless 7 3
res shower schedule 9 Dimensionless 7 3
res sink schedule Dimensionless 7 3
res sink schedule 1 Dimensionless 7 3
res sink schedule 10 Dimensionless 7 3
res sink schedule 11 Dimensionless 7 3
res sink schedule 12 Dimensionless 7 3
res sink schedule 13 Dimensionless 7 3
res sink schedule 14 Dimensionless 7 3
res sink schedule 15 Dimensionless 7 3
res sink schedule 16 Dimensionless 7 3
res sink schedule 17 Dimensionless 7 3
res sink schedule 18 Dimensionless 7 3
res sink schedule 19 Dimensionless 7 3
res sink schedule 2 Dimensionless 7 3
res sink schedule 20 Dimensionless 7 3
res sink schedule 21 Dimensionless 7 3
res sink schedule 22 Dimensionless 7 3
res sink schedule 23 Dimensionless 7 3
res sink schedule 24 Dimensionless 7 3
res sink schedule 25 Dimensionless 7 3
res sink schedule 26 Dimensionless 7 3
res sink schedule 27 Dimensionless 7 3
res sink schedule 28 Dimensionless 7 3
res sink schedule 29 Dimensionless 7 3
res sink schedule 3 Dimensionless 7 3
res sink schedule 30 Dimensionless 7 3
res sink schedule 31 Dimensionless 7 3
res sink schedule 32 Dimensionless 7 3
res sink schedule 33 Dimensionless 7 3
res sink schedule 34 Dimensionless 7 3
res sink schedule 35 Dimensionless 7 3
res sink schedule 36 Dimensionless 7 3
res sink schedule 37 Dimensionless 7 3
res sink schedule 38 Dimensionless 7 3
res sink schedule 39 Dimensionless 7 3
res sink schedule 4 Dimensionless 7 3
res sink schedule 40 Dimensionless 7 3
res sink schedule 41 Dimensionless 7 3
res sink schedule 42 Dimensionless 7 3
res sink schedule 43 Dimensionless 7 3
res sink schedule 44 Dimensionless 7 3
res sink schedule 5 Dimensionless 7 3
res sink schedule 6 Dimensionless 7 3
res sink schedule 7 Dimensionless 7 3
res sink schedule 8 Dimensionless 7 3
res sink schedule 9 Dimensionless 7 3
RestaurantFastFood ACTIVITY_SCH ActivityLevel 0 1
RestaurantFastFood BLDG_EQUIP_SCH Dimensionless 1 1
RestaurantFastFood BLDG_LIGHT_DINING_SCH_2013 Dimensionless 2 1
RestaurantFastFood BLDG_OCC_SCH Dimensionless 2 1
RestaurantFastFood CLGSETP_SCH_NO_OPTIMUM Temperature 1 1
RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM Temperature 1 1
RestaurantFastFood INFIL_SCH_PNNL Dimensionless 1 1
RetailStandalone ACTIVITY_SCH ActivityLevel 0 5
RetailStandalone BLDG_EQUIP_SCH Dimensionless 2 5
RetailStandalone BLDG_LIGHT_ENTRY_SCH_2013 Dimensionless 2 1
RetailStandalone BLDG_LIGHT_SCH_2013 Dimensionless 2 4
RetailStandalone BLDG_OCC_SCH_2010 Dimensionless 2 5
RetailStandalone CLGSETP_SCH_YES_OPTIMUM Temperature 2 4
RetailStandalone FRONT_ENTRY_COOLING Temperature 0 1
RetailStandalone HTGSETP_SCH_NO_OPTIMUM Temperature 2 1
RetailStandalone HTGSETP_SCH_YES_OPTIMUM Temperature 2 4
RetailStandalone INFIL_SCH_PNNL Dimensionless 2 5
Schedule Ruleset 1 ActivityLevel 0 45
Schedule Ruleset 317 Dimensionless 0 1
Schedule Ruleset 318 Dimensionless 0 5
Service Preheat Water Loop Piping Air Temp - 70F Temperature 0 1
Service Preheat Water Loop Piping Air Velocity - 0.67mph Temperature 0 1
SmallHotel UnitHeater ClgSP Sch Temperature 0 10
Waste Water Tank Ambient Temp Schedule Temperature 0 1
Work Efficiency Schedule Dimensionless 0 7
ZE_AEDG_Multifamily_Corridor_ClgSetp_Sch Temperature 0 4
ZE_AEDG_Multifamily_Corridor_HtgSetp_Sch Temperature 0 4

Measure Warnings


Description Count
Number of measures in workflow 40
Number of measures with warnings 4
Total number of warnings 175

Warning
Unexpected space type 'Exercise'.
Unexpected space type 'ElevatorCore'.
Unexpected space type 'Stair'.
Unexpected space type 'Core_Retail'.
Unexpected space type 'Storage'.
Unexpected space type 'Dining'.
Unexpected space type 'Meeting'.
Unexpected space type 'Storage'.
Unexpected space type 'Office'.
Unexpected space type 'Entry'.
Unexpected space type 'PublicRestroom'.
Unexpected space type 'Corridor'.

Warning
Removing 3 collinear vertices from Face 117.
Removing 1 collinear vertices from Face 246.
Removing 1 collinear vertices from Face 432.
Removing 1 collinear vertices from Face 431.
Removing 1 collinear vertices from Face 583.
Removing 1 collinear vertices from Face 582.
Removing 1 collinear vertices from Face 319.
Removing 1 collinear vertices from Face 320.
Removing 1 collinear vertices from Face 259.
Removing 1 collinear vertices from Face 362.
Removing 1 collinear vertices from Face 363.
Removing 20 collinear vertices from Face 0.
Removing 18 collinear vertices from Face 168.
Removing 1 collinear vertices from Face 471.
Removing 1 collinear vertices from Face 470.
Removing 1 collinear vertices from Face 266.
Removing 1 collinear vertices from Face 454.
Removing 1 collinear vertices from Face 453.
Removing 1 collinear vertices from Face 438.
Removing 1 collinear vertices from Face 439.
Removing 1 collinear vertices from Face 395.
Removing 1 collinear vertices from Face 394.
Removing 1 collinear vertices from Face 192.
Removing 1 collinear vertices from Face 159.
* See OSW file for full list of warnings. This measure has 49 warnings.

Warning
Could not find existing window with construction as guide for new windows. Using a catchall glazing of Dbl Clr 3mm/13mm Air.

Warning
[openstudio.standards.SpaceType] Space type properties lookup failed: {"template"=>"ZE AEDG Multifamily", "building_type"=>"MidriseApartment", "space_type"=>"living"}.
[openstudio.standards.SpaceType] Space type properties lookup failed: {"template"=>"ZE AEDG Multifamily", "building_type"=>"MidriseApartment", "space_type"=>"living"}.
[openstudio.model.Model] The run completed but had the following severe errors: CheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_1_2" did not converge after 25 warmup days. See Warmup Convergence Information in .eio file for details. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.34E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.44E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.7740E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 4.4442 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_1_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 7.54E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.26E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1101 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 4.4193 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_1_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 2.58E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.48E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.4859E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.7832 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_2_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 8.60E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.48E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1035 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 4.4762 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_2_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 9.66E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.37E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1093 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 4.4516 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_2_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 4.53E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.62E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.0954E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.7838 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_3_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 8.09E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.34E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1074 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 4.4506 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_3_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.12E-004 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.35E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1110 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 4.4268 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_3_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.93E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.62E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.4709E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.7826 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_4_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 8.03E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.32E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1077 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 4.4500 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_4_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.14E-004 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.35E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1111 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 4.4262 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="0_BDRM_4_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 6.02E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.62E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.4970E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.7826 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_1_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.44E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.12E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.2655E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 5.7799 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_1_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.18E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 9.90E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1039 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 5.7472 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_1_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.38E-003 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.14E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 8.4614E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8230 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_2_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 9.85E-006 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.07E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.6832E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 5.7544 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_2_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.96E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 9.91E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1053 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 5.7231 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_2_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.31E-003 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.14E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 8.7766E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8222 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_3_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 6.73E-006 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.06E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.5450E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 5.7540 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_3_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 2.07E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 9.94E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1054 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 5.7228 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_3_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.30E-003 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.14E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 8.7961E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8222 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_4_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 2.22E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.06E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 8.4413E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 7.0918 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_4_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 3.28E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 9.98E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.8893E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 7.0529 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_4_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.23E-006 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.03E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 7.9657E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8496 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_5_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.70E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.03E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 8.6645E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 7.0884 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_5_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 3.29E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 9.86E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 9.9805E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 7.0493 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_5_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 8.10E-006 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.03E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 7.9791E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8493 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_6_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 2.53E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.08E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1004 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 5.7694 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_6_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 4.82E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.10E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1052 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 5.7374 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_6_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.78E-005 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 1.23E-010 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 8.6781E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8220 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_7_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.62E-006 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 9.60E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 8.6237E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8761 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_7_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 8.10E-006 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 8.88E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 0.1001 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 7.0293 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="1_BDRM_7_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 1.22E-003 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 9.66E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 8.1212E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8495 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_1_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 4.86E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 7.23E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 5.9774E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8963 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_1_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.70E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 7.17E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 6.8926E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8951 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_1_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.76E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 6.94E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 5.5926E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8630 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_2_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 4.84E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 6.48E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 5.7401E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.9052 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_2_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.84E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 6.30E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 6.6479E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.9042 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_2_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.69E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 6.13E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 5.3247E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8742 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_3_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.70E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 6.49E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 7.2262E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.9012 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_3_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.68E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 6.82E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 6.8100E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.9001 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="2_BDRM_3_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 5.18E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 6.82E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 5.3256E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.8689 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="3_BDRM_1_3" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 4.98E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 5.10E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 6.3771E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.9232 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="3_BDRM_1_4" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 4.72E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 5.02E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 4.7822E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.9002 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence\nCheckWarmupConvergence: Loads Initialization, Zone="3_BDRM_2_2" did not converge after 25 warmup days. ...Environment(SizingPeriod)="LOS ANGELES INTL ARPT ANN HTG 99.6% CONDNS DB 1" ..Max Temp Comparison = 4.48E-008 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Min Temp Comparison = 5.07E-011 vs Temperature Convergence Tolerance=0.40 - Pass Convergence ..Max Heat Load Comparison = 5.7147E-002 vs Loads Convergence Tolerance=4.00E-002 - Fail Convergence ..Max Cool Load Comparison = 0.9239 vs Loads Convergence Tolerance=4.00E-002 - Pass Convergence
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 5891.133809648212 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 5891.133809648212 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 10724.1369194935 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 10724.1369194935 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 7357.596231265581 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 7357.596231265581 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 5262.21434123061 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 5262.21434123061 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 9986.034141516582 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 9986.034141516582 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 6998.442469298937 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 6998.442469298937 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 5257.446562272373 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 5257.446562272373 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 9376.69948295519 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 9376.69948295519 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 6382.936319633739 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 6382.936319633739 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 5260.331921149397 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:60:in `coil_cooling_dx_single_speed_standard_minimum_cop'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 5260.331921149397 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
[openstudio.standards.Model] Find object search criteria returned 2 results, the first one will be returned. Called from :/ruby/2.5.0/gems/openstudio-standards-0.2.11/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb:188:in `coil_cooling_dx_single_speed_apply_efficiency_and_curves'. Search criteria: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "subcategory"=>"Split System"}, capacity = 9328.075610450423 All results: {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"All Other", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"} {"template"=>"ZE AEDG Multifamily", "cooling_type"=>"AirCooled", "heating_type"=>"Electric Resistance or None", "subcategory"=>"Split System", "minimum_capacity"=>0.0, "maximum_capacity"=>9999999.0, "start_date"=>"1919-09-09T00:00:00+00:00", "end_date"=>"2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio"=>nil, "minimum_energy_efficiency_ratio"=>11.2, "minimum_integrated_part_load_value"=>nil, "minimum_integrated_energy_efficiency_ratio"=>12.9, "ptac_eer_coefficient_1"=>nil, "ptac_eer_coefficient_2"=>nil, "minimum_scop"=>nil, "cool_cap_ft"=>"CoilClgDXQRatio_fTwbToadbSI", "cool_cap_fflow"=>"CoilClgDXDblQRatio_fCFMRatio", "cool_eir_ft"=>"CoilClgDXEIRRatio_fTwbToadbSI", "cool_eir_fflow"=>"CoilClgDXDblEIRRatio_fCFMRatio", "cool_plf_fplr"=>"CoilClgDXEIRRatio_fQFrac", "notes"=>" From 90.1-2016 Table 6.8.1-4"}
* See OSW file for full list of warnings. This measure has 113 warnings.